Indirect evaporative air cooler with dehumidifier
USD $1 - $100,000 /Unit
Min.Order:1 Unit
Aolan (Fujian) Industry Co., Ltd.
high efficiency liquid dessicant normal temperature dehumidification dryer units
fresh air flow 3000 m3/h liquid desiccant air conditioning with purified air function
Most energy saving Liquid desiccant air dehumidifier 850m3/h AHLD-DD003
cooling capacity 6.1kw and power 3.1kw liquid dehumidifier industrial
dehumidifying air 850m3/h fully closed scroll compressed air dehumidifier
Brine solution dehumidifier an industrial dehumidifier with air condtion function
Introduction
This brine solution dehumidifier suits for a whole years climates,summer time or winter time. And it's especially suitable for air conditioning systems with temperature and humidity independent controlled, Enclosed room needs deep dehumidifying where demands a constant temperature and humidity, such as ICU(Intensive care unit), R&D buildings, laboratory, exhibition centers, hotels, apartments, machine room,factories and military.
Application
Specification
Model(TAH-xx) | 10 | 12 | 15 | 20 | 25 | 30 | 40 | ||
Power Source | 3PH-380V-50Hz | ||||||||
Supply Air Rate | m3/h | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 | 40000 | |
Return Air Rate | m3/h | 7000 | 8400 | 10500 | 14000 | 17500 | 21000 | 28000 | |
Fresh Air Rate | m3/h | 3000 | 3600 | 4500 | 6000 | 7500 | 9000 | 12000 | |
Cooling Capacity | kW | 87 | 104 | 130 | 174 | 216 | 260 | 347 | |
Dehumidification | kg/h | 64 | 77 | 96 | 128 | 160 | 192 | 256 | |
Heating | kW | 92 | 111 | 139 | 185 | 231 | 277 | 370 | |
Moisture | kg/h | 24 | 29 | 37 | 49 | 61 | 73 | 98 | |
Power | kW | 18.7 | 21.1 | 26.4 | 34.0 | 41.6 | 52.8 | 70.4 | |
Air supply excess pressure | Pa | 350 | 370 | 350 | 350 | 350 | 350 | 350 | |
Noise | dB(A) | 65 | 66 | 66 | 68 | 70 | 73 | 75 | |
Weight | kg | 2660 | 2956 | 3823 | 4521 | 5263 | 6283 | 7355 | |
Fresh Air Section | |||||||||
Fresh Air Rate | m3/h | 3000 | 3600 | 4500 | 6000 | 7500 | 9000 | 12000 | |
Supply Air Rate | m3/h | 3000 | 3600 | 4500 | 6000 | 7500 | 9000 | 12000 | |
Cooling Capacity | kW | 63 | 75 | 94 | 125 | 156 | 187 | 250 | |
Dehumidification | kg/h | 62 | 74 | 93 | 124 | 155 | 186 | 248 | |
Heating | kW | 41 | 49 | 61 | 81 | 101 | 122 | 162 | |
Moisture | kg/h | 24 | 29 | 37 | 49 | 61 | 73 | 98 | |
Power | kW | 13.8 | 15.8 | 20.1 | 25.8 | 31.3 | 40.5 | 53.9 | |
Compressor Type | Fully Closed Scroll Compressor | ||||||||
Throttle Type | Thermal Expansion Valve | ||||||||
Refrigerant | R407C | ||||||||
Exhaust Fan Type | Outer Rotor Centrifugal Fan | ||||||||
Filter Grade | Primary(G4) | ||||||||
Air exhaust excess pressure | Pa | 170 | 180 | 170 | 180 | 190 | 170 | 430 | |
Weight | kg | 2050 | 2200 | 2650 | 3080 | 3580 | 4350 | 5140 | |
Mixed Air Section | |||||||||
Filter Grade | Primary(G4) | ||||||||
Weight | kg | 100 | 140 | 175 | 195 | 210 | 265 | 320 | |
Cold And hot Coil Section | |||||||||
Cooling Capacity | kW | 24.2 | 29.1 | 36.4 | 48.5 | 60.6 | 72.7 | 96.9 | |
Heating Capacity | kW | 51.9 | 62.2 | 77.8 | 103.7 | 129.7 | 155.6 | 207.5 | |
water inlet/outlet temp. | ℃ | Cold Water:14/19;Hot Water:50/45 | |||||||
cold-water flow | m3/h | 4.2 | 5.0 | 6.2 | 8.3 | 10.4 | 12.5 | 16.6 | |
hot-water flow | m3/h | 8.9 | 10.7 | 13.3 | 17.8 | 22.2 | 26.7 | 35.6 | |
Connecting Pipe | DN40 | DN40 | DN50 | DN50 | DN65 | DN65 | DN80 | ||
Water Resistance | kPa | <60 | |||||||
Weight | kg | 170 | 230 | 320 | 400 | 510 | 610 | 740 | |
Supply Air Section | |||||||||
Fan Type | Belt-driven Double Inlet Centrifugal Fan | ||||||||
Power | kW | 5.2 | 5.6 | 6.6 | 8.7 | 10.8 | 13.0 | 17.3 | |
Weight | kg | 340 | 386 | 678 | 846 | 963 | 1058 | 1155 |
Notes:1.Nominal cooling and dehumidification working conditions: fresh air dry bulb temperature 36℃, relative humidity 65%,; returned air dry bulb temperature 26℃, relative humidity 60%; supply air dry bulb temperature 17℃, wet bulb temperature 16.0℃.
2. Nominal heating and humidification working conditions: fresh air dry bulb temperature -5℃, relative humidity 50%,;returned air dry bulb temperature 20℃, relative humidity 50%; supply air dry bulb temperature 35℃, wet bulb temperature 19.0℃.
3. The above section and setting are only for reference. Pls choose and adjust based on actual project requirement, or provided by customer.
Dimension Drawing
Model(TAH-xx) | 10 | 12 | 15 | 20 | 25 | 30 | 40 | |||
Sectional size W*H (mm) | ||||||||||
W | mm | 1500 | 1500 | 1850 | 1850 | 2300 | 2300 | 2300 | ||
H1 | mm | 2300 | 2300 | 2400 | 2400 | 2500 | 2800 | 3000 | ||
H2 | mm | 1300 | 1500 | 1500 | 1800 | 1800 | 2050 | 2500 | ||
L=L1+L2+L3+L4 | mm | 5770 | 5770 | 6350 | 6450 | 6850 | 7180 | 7280 | ||
Function section size (mm) | ||||||||||
Fresh Air Dehumidification Section | Section Length | L1 | mm | 3300 | 3300 | 3500 | 3500 | 3700 | 3700 | 3800 |
Return Air Outlet One | J | mm | 350 | 400 | 400 | 450 | 450 | 550 | 650 | |
K | mm | 1100 | 1100 | 1500 | 1500 | 1900 | 1900 | 1900 | ||
Fresh Air Outlet | E | mm | 500 | 600 | 600 | 680 | 650 | 800 | 950 | |
F | mm | 700 | 700 | 900 | 900 | 1300 | 1300 | 1300 | ||
Exhaust Air Outlet | C | mm | 200 | 200 | 300 | 300 | 300 | 300 | 400 | |
D | mm | 310 | 350 | 390 | 450 | 450 | 450 | 627 | ||
Mixing section | Section Length | L2 | mm | 420 | 420 | 500 | 600 | 600 | 730 | 730 |
Return Air Outlet Two | M | mm | 320 | 320 | 400 | 500 | 500 | 630 | 630 | |
N | mm | 1000 | 1250 | 1250 | 1600 | 1600 | 2000 | 2000 | ||
Cooling Coiler Section | Section Length | L3 | mm | 750 | ||||||
Cold and hot water pipe Outlet | DN1 | mm | DN40 | DN40 | DN50 | DN50 | DN65 | DN65 | DN80 | |
DN2 | mm | DN40 | DN40 | DN50 | DN50 | DN65 | DN65 | DN80 | ||
Supply Air Section | Section Length | L4 | mm | 1300 | 1300 | 1600 | 1600 | 1800 | 2000 | 2000 |
Supply Air Outlet | A | mm | 485 | 550 | 605 | 675 | 740 | 785 | 950 | |
B | mm | 412 | 466 | 532 | 580 | 650 | 700 | 780 |
Note:As our products are improved continuously, specifications in the tables are subject to change without notice.