Power source 3PH-380V-50Hz desiccant R407C deep desiccant dehumidifier cooling units
USD $1 - $100,000 /Unit
Min.Order:1 Unit
Aolan (Fujian) Industry Co., Ltd.
Power source 3PH-380V-50Hz desiccant R407C deep dehumidification cooling units
80% energy saving deep commerical dehumidifier / liquid desiccant air conditioning / desiccant wheel
commercial dehumidifier / liquid desiccant air conditioning / wheel desiccant
commercial dehumidifier / liquid desiccant air conditioning / industrial air conditioning
Power source 3PH-380V-50Hz desiccant R407C deep desiccant dehumidifier cooling units
Introduction
Normal dehumidification dryer units is based on deep dehumidification cooling units. It uses its own heat to reheat the supply air which further enhances the air absorption ability. It can be mainly applied in the workshops or warehouses which require low humidity, such as pharmacy, electronics, biological ,lithium battery, foods and military industry, ect.
Application
Outdoor Environment Temperature:-5℃-40℃;
Indoor Relative Humidity:15%-30%;
Working Principle
Features
1) Fashionable and attractive structure, easy installation and maintenance. Sections can be combined freely with different functions
2) International quality, stable running
a. The running parts we adopt, including cooling parts, controlling components, pump, fan, etc, are coming from international famous brands, thus the quality is ensured;
b. Intelligent control, human-computer interface and standard communication protocol with high accuracy
3) Professional design for anti-corrosion and rust-proof ensures long working life
a. Heat exchanger is made of pure titanium pope, never rust;
b. The units are closed to avoid assault from mouse ,insects, etc;
c. Water tank is injection molding by PP, and the pope system is PRR seamless welded and the liquid will never leak
4)High-end optional configuration, strong applicability
a. With dehumidification accelerator inside, by using its won heating, it will accelerate the dehumidifying speed when the units on
b. With dehumidification regeneration balancer, there is no need to fill water outside to avoid the water softened.
Specification
Model (DD-xx) | 03 | 06 | 09 | 12 | 15 | 18 | 21 | 24 | ||
Power Source | 3PH-380V-50Hz | |||||||||
Dehumidification Air Rate | m3/h | 850 | 1700 | 2550 | 3400 | 4250 | 5100 | 5950 | 6800 | |
Exhaust Air Rate | m3/h | 1500 | 3000 | 4500 | 6000 | 7500 | 9000 | 10500 | 12000 | |
Cooling Capacity | kW | 6.1 | 12.3 | 18.4 | 24.6 | 30.7 | 36.9 | 43.0 | 49.2 | |
Dehumidification | kg/h | 3 | 6 | 9 | 12 | 15 | 18 | 21 | 24 | |
Power | kW | 3.1 | 6.0 | 9.2 | 12.6 | 16.8 | 17.4 | 23.8 | 29.4 | |
Compressor Type |
Full Closed Scroll Compressor
| |||||||||
Throttle Type |
The Balance Type Thermal Expansion Valve
| |||||||||
Desiccant | R407C | |||||||||
Filtration Grade | Primary (G4) | |||||||||
Fan Type | The Outer Rotor Centrifugal Fan | |||||||||
Supply air over-bottom pressure | Pa | 110 | 110 | 120 | 160 | 180 | 200 | 300 | 310 | |
Exhaust Air over-bottom pressure | Pa | 120 | 110 | 120 | 200 | 260 | 240 | 470 | 450 | |
Weight | kg | 650 | 1010 | 1550 | 1800 | 2150 | 2680 | 3180 | 3750 |
Notes: 1) Nominal cooling and dehumidification working conditions: fresh air dry bulb temperature 35℃,wet bulb temperature 27.0℃; returned air dry bulb temperature 25℃, relative humidity 25%;2)Running environment: clean plant with retaining structure, story height less than 2.5m.
Dimension Drawing
Model(DD-xx) | 03 | 06 | 09 | 12 | 15 | 18 | 21 | 24 | ||
L | mm | 2300 | 2600 | 2600 | 2600 | 3000 | 3000 | 3200 | 3200 | |
W | mm | 800 | 1300 | 1500 | 1500 | 1850 | 1850 | 2300 | 2300 | |
H | mm | 2300 | 2300 | 2300 | 2300 | 2400 | 2400 | 2500 | 2800 | |
Supply Air Outlet | A | mm | 150 | 150 | 240 | 240 | 240 | 240 | 300 | 300 |
B | mm | 315 | 315 | 360 | 360 | 360 | 410 | 450 | 450 | |
Exhaust Air Outlet | C | mm | 150 | 200 | 200 | 240 | 300 | 300 | 350 | 350 |
D | mm | 265 | 330 | 380 | 410 | 450 | 450 | 515 | 515 | |
Return Air Outlet | E | mm | 350 | 500 | 500 | 600 | 600 | 680 | 650 | 800 |
F | mm | 420 | 700 | 700 | 700 | 900 | 900 | 1300 | 1300 | |
Fresh Air Outlet | J | mm | 350 | 350 | 350 | 400 | 400 | 450 | 450 | 550 |
K | mm | 420 | 1100 | 1100 | 1100 | 1500 | 1500 | 1900 | 1900 |
Note:As our products are improved continuously, specifications in the tables are subject to change without notice.