1-50J/cm2 Promotion!!! Home Use Mini Ipl Hair Removal Hair Removal And Facial Rejuvenation Machine Bikini Hair Removal
USD $1 - $1,450 /Piece
Min.Order:1 Piece
Guangzhou Lingmei Electronic Technology Co., Ltd.
Product Introduction
Precipulse IPL Therapy System holds a wavelength from 420nm to 1200nm.Different wavelength is adopted in treatment based on clinical requirements.This system is focus on treating various kinds of clinical indications including pigmented lesions and vascular diseased as well as hair removal and skin rejuvenation.It contains a wide clinical application range.
Working Theory:
Applying the technology of IPL and Bipolar Radio Frequency, the system acts on the entire corium layer, epidermal layer and subcutaneous tissue. On one hand, IPL destroys pathological pigments by photothermolysis effect, and stimulates the collagen and elastic fiber and gets the effect of tightening and whitening, on the other hand, biopolar RF release about 10 MHZ radio wave, high frequency vibration makes the skin molecule creating heat energy by friction, when the temperature reaches 68℃-72℃,the collagens extend will reproduce and recombine, enhance getting the effect of tightening skin and removing wrinkles.
Product name:Promotion!!! home use mini ipl hair removal and facial rejuvenation machine
E-Light is the first and only technology that combines optical (light) energy. Gentle pulses of targeted energy isolate the treatment area and leave the surrounding skin free from potentially harmful side effects. In addition to permanent hair reduction for most hair colors and skin types, E-Light effectively and comfortably treats rosacea, spider veins; skin imperfections caused by sun damage, age spots, enlarged pores and uneven skin tones. A series of E-Light treatments will leave your skin smoother clearer with a tighter more youthful appearance.
This device is composed of three parts: (1) main unit, (2) control panel, and (3) the E-Light treatment handpiece
The control panel includes the color 8.4” LCD screen, the power switch and emergency shut off switch. The LCD screen shows the work mode and the parameters of the system.
1. Permanent hair removal
2. Skin rejuvenation
3. Reduction of pigmented lesions
4. Wrinkle removal
5. Acne Therapy
6. Freckle, vascular lesions and facial blemish removal
The Main unit is the integral part of this system; it consists of the following parts.
1.The Power supply module: regulates electrical supply to the entire system.
2.The Control module: Regulates and coordinates the various components of the system for optimum performance.
3.The display module: Displays various information of the system and accept users instruction.
4.High current capacitors: Delivers adequate electrical energy to guarantee sufficient power during operation.
5.Cooling system: Maintains a stable thermal environment for optimum performance.
The E-Light handle consists of a (1) Cable housing: this contains the power cable, liquid coolant tubing, control data cable; (2) E-Light head: this houses the control switch, flash lamp, sapphire crystal, filter piece and electronic semi-conductor cooling system.
Pressing on the trigger on the E-Light treatment head discharges the flash lamp at the settings as displayed on the control panel. Pushing down the foot switch like-wise discharges the device (on selected models only). The supplied sapphire crystal measures 12mmx 35 mm and is superior in both clarity and longetivity, thereby increasing both the efficiency of the flash lamp and lifespan of the treatment head. It is very important to keep the sapphire crystal clean. Make sure to clean this with a soft cloth after each treatment. A disinfectant such as alcohol can be used between treatments. Dried gel on the crystal filter will reduce efficiency of the flash lamp. Replace the plastic guard over the filter to prevent damage. In the event that the sapphire crystal is damaged (i.e. nicked or cracked) contact your dealer immediately.
1.5 Protection Glasses
One pair of protective glasses is provided with the device. The opaque glasses are to be worn by the patient and the filtered 430-1200 nm glasses are to be worn by the operator. Despite wearing the protective glasses, avoid staring directly into the intense pulses of light during the treatment. Only personnel wearing protective glasses may be allowed to observe the treatment.
The light-coupling gel is used to maximize the conduction of light from the flash lamp to the skin. The light-coupling gel must be clear/transparent and not colored/tinted. Colored gels absorb light therefore reducing the effectiveness of the treatment. The light-coupling gel must be chilled but not frozen. Frozen gel diffuses the light emitted by the flash lamp reducing its efficacy. Light-coupling gels must be non-alcohol based. The E-Light produces considerable heat; flammable material must be kept clear of the treatment area.
Working temperature scope : +15~+30°
Relative humidity scope : 30%~80%
Atmospheric pressure barometric : 86kpa -106kpa
The store environment temperature : +5°°
Power supply : 230V AC , 50/60Hz, 10A;
or 115V AC , 50/60Hz, 20A
1.8 detailed list of equipment of this ipl hair removal:
1.Main host
2.The handpiece X1
3.Protective glassesX1
4.Protective goggleX1
5.Power cableX1
6.Foot switchX1
7.FunnelX1
8.Plastics hoseX1
9.Key X2
No power | Check power cable |
Check circuit breaker / fuse | |
Check key switch | |
Disengage the emergency cut off switch by rotating towards the direction of the arrows indicated | |
Notify your distributor | |
Key pads are none responsive | Please contact the dealer. |
System failed to initialize | Not enough power, please check main power supply. Please contact the dealer. |
Malfunction of flash lamp on the E-Light treatment head | The treatment head / flash lamp has reached its maximum life span (300,000) shots. Replace the treatment head Suggset you to replace the handle after 300,000 shots , or the treatment effect will not be good |
The E-Light treatment head is probably damaged, please change the E-Light treatment head or contact the dealer. | |
The E-Light treatment head is leaking | O-Ring for faucet is likely to lose, Pull out the treatment handpiece, then take out O-Ring from accessories and push into water conduit.
The E-Light treatment head is probably damaged, please change the E-Light treatment head or contact the dealer. |
The treatment handle is warm | The system is designed for continued used for up four hours in optimal environmental temperature and humidity.
Always place the system on standby mode while awaiting treatment. The system might have been left on for an extended period. Turn the unit off, let it cool down for half an hour then re- start
Contact the dealer. |
The power of The E-Light treatment head has weakened | The treatment head has nearly reached its maximum life span the fluence can be adjusted by a few joules to compensate. |
IPL SHR Machine advantages:
1. The pulse energy keep stable, not fade away
2. Icons combined with letters on the screen, more easy for understanding and operating
3. Two fans equiped on the sides for better heat dissipation
4. Inner the back of machine, the lines are neat, the consumables keep on the outside, for easy replacement
Dark hair | Shorter pulse width |
Light hair | Longer pulse width |
Deep hair | Longer pulse width |
Superficial hair | Shorter pulse width |
Thick hair | Longer pulse delay & lower fluence |
Thin hair | Shorter pulse delay & higher fluence |
Dense hair growth | Lower fluence |
Sparse hair growth | Higher fluence |
Darker Skin color | Longer pulse delay & Lower fluence |
Lighter skin color | Shorter pulse delay & Higher fluence |
More sensitive skin | Lower fluence |
Less sensitive skin | Higher fluence |
Start with a low fluence (i.e. 25 J/cm22 2
Please note that treatment over bony areas such as the malar area, forehead and shins produces more discomfort so reduce the fluence by 2-3 joules. When treating very densely pigmented areas reduce fluence by 2-3 joules.
1.11 Specification
Operation Inteface | 8 inch TFT Screen |
Wavelength | 750nm(E-Light) |
Working Mode | Multi-Pulse&Single-Pulse mode E-Light Working |
Spot Size | 15X50mm; |
Energy | 1-26J/cm2(E-Light) |
Pulse Width | 1-9.9ms |
Pulse Amount | 1-6 |
Handle | 1X750nm(E-Light) |
E-Light Drive Power | 2000W |
Contious shottingnon-stop | 14 working stand-by working |
Handpiece lifetime | 2000,000 shots times for each handle |
Weight | 48KG |
1.12 operation interface:
The Advanced Technology Of IPL SHR
SHR stands for Super Hair Removal, a technology for permanent hair removal which is having a sweeping success. The system combines laser technology and the benefits of the pulsating light method achieving practically painless results.
Even hairs which until now have been difficult or even impossible to be removed, can now be treated. “In Motion” represents a breakthrough in permanent hair removal with light technology. The treatment is more pleasant than with the conventional systems and your skin is better protected.