Vertical Mini Ipl Hair Removal Device/home Use 640-1200nm Permanent Hair Removal Ipl Skin Lifting
USD $1 - $1,450 /Piece
Min.Order:1 Piece
Guangzhou Lingmei Electronic Technology Co., Ltd.
System Characteristics
1.The treatment head of E-light mainly combined with three parts: bipolar radio frequency+low-energy pulse light energy+epidermal cooling.
2.Treatment result is obviously enhanced on clinic,and the various skin problems like wrinkle and telangiectasia are greatly improved.
3.Multi-features of E-light machine lead to the machine as the best choice for patient:comfortable treatment,better effect,faster results and minimal side effects,etc.
4.Adapting to the wider population,safe to all kinds of skin types,it also can be used for the treatment of skin Type IV and skin type V.
5.Easy operation,you only need to adjust the energy of IPL and RF individually.
6.Pre-cooling to the epidermis,this can result in temperature difference between epidermis and dermis,the energy lunched by RF act on the pre-warmed aimed-tissue(such as veins,hair follicles,melanin,etc.),so as to achieve the best RF penetration effect.
Product name: Mini ipl hair removal device/home use permanent hair removal ipl
E-Light is the first and only technology that combines optical (light) energy. Gentle pulses of targeted energy isolate the treatment area and leave the surrounding skin free from potentially harmful side effects. In addition to permanent hair reduction for most hair colors and skin types, E-Light effectively and comfortably treats rosacea, spider veins; skin imperfections caused by sun damage, age spots, enlarged pores and uneven skin tones. A series of E-Light treatments will leave your skin smoother clearer with a tighter more youthful appearance.
This device is composed of three parts: (1) main unit, (2) control panel, and (3) the E-Light treatment handpiece
The control panel includes the color 8.4” LCD screen, the power switch and emergency shut off switch. The LCD screen shows the work mode and the parameters of the system.
1. Permanent hair removal
2. Skin rejuvenation
3. Reduction of pigmented lesions
4. Wrinkle removal
5. Acne Therapy
6. Freckle, vascular lesions and facial blemish removal
The Main unit is the integral part of this system; it consists of the following parts.
1.The Power supply module: regulates electrical supply to the entire system.
2.The Control module: Regulates and coordinates the various components of the system for optimum performance.
3.The display module: Displays various information of the system and accept users instruction.
4.High current capacitors: Delivers adequate electrical energy to guarantee sufficient power during operation.
5.Cooling system: Maintains a stable thermal environment for optimum performance.
The E-Light handle consists of a (1) Cable housing: this contains the power cable, liquid coolant tubing, control data cable; (2) E-Light head: this houses the control switch, flash lamp, sapphire crystal, filter piece and electronic semi-conductor cooling system.
Pressing on the trigger on the E-Light treatment head discharges the flash lamp at the settings as displayed on the control panel. Pushing down the foot switch like-wise discharges the device (on selected models only). The supplied sapphire crystal measures 12mmx 35 mm and is superior in both clarity and longetivity, thereby increasing both the efficiency of the flash lamp and lifespan of the treatment head. It is very important to keep the sapphire crystal clean. Make sure to clean this with a soft cloth after each treatment. A disinfectant such as alcohol can be used between treatments. Dried gel on the crystal filter will reduce efficiency of the flash lamp. Replace the plastic guard over the filter to prevent damage. In the event that the sapphire crystal is damaged (i.e. nicked or cracked) contact your dealer immediately.
1.5 Protection Glasses
One pair of protective glasses is provided with the device. The opaque glasses are to be worn by the patient and the filtered 430-1200 nm glasses are to be worn by the operator. Despite wearing the protective glasses, avoid staring directly into the intense pulses of light during the treatment. Only personnel wearing protective glasses may be allowed to observe the treatment.
The light-coupling gel is used to maximize the conduction of light from the flash lamp to the skin. The light-coupling gel must be clear/transparent and not colored/tinted. Colored gels absorb light therefore reducing the effectiveness of the treatment. The light-coupling gel must be chilled but not frozen. Frozen gel diffuses the light emitted by the flash lamp reducing its efficacy. Light-coupling gels must be non-alcohol based. The E-Light produces considerable heat; flammable material must be kept clear of the treatment area.
Working temperature scope : +15~+30°
Relative humidity scope : 30%~80%
Atmospheric pressure barometric : 86kpa -106kpa
The store environment temperature : +5°°
Power supply : 230V AC , 50/60Hz, 10A;
or 115V AC , 50/60Hz, 20A
1.8 detailed list of equipment of this device:
1.Main host
2.The handpiece X1
3.Protective glassesX1
4.Protective goggleX1
5.Power cableX1
6.Foot switchX1
7.FunnelX1
8.Plastics hoseX1
9.Key X2
No power | Check power cable |
Check circuit breaker / fuse | |
Check key switch | |
Disengage the emergency cut off switch by rotating towards the direction of the arrows indicated | |
Notify your distributor | |
Key pads are none responsive | Please contact the dealer. |
System failed to initialize | Not enough power, please check main power supply. Please contact the dealer. |
Malfunction of flash lamp on the E-Light treatment head | The treatment head / flash lamp has reached its maximum life span (300,000) shots. Replace the treatment head Suggset you to replace the handle after 300,000 shots , or the treatment effect will not be good |
The E-Light treatment head is probably damaged, please change the E-Light treatment head or contact the dealer. | |
The E-Light treatment head is leaking | O-Ring for faucet is likely to lose, Pull out the treatment handpiece, then take out O-Ring from accessories and push into water conduit.
The E-Light treatment head is probably damaged, please change the E-Light treatment head or contact the dealer. |
The treatment handle is warm | The system is designed for continued used for up four hours in optimal environmental temperature and humidity.
Always place the system on standby mode while awaiting treatment. The system might have been left on for an extended period. Turn the unit off, let it cool down for half an hour then re- start
Contact the dealer. |
The power of The E-Light treatment head has weakened | The treatment head has nearly reached its maximum life span the fluence can be adjusted by a few joules to compensate. |
Dark hair | Shorter pulse width |
Light hair | Longer pulse width |
Deep hair | Longer pulse width |
Superficial hair | Shorter pulse width |
Thick hair | Longer pulse delay & lower fluence |
Thin hair | Shorter pulse delay & higher fluence |
Dense hair growth | Lower fluence What's IPL? IPL is the abbreviation of intense pulsed light. IPL is the kind of broad spectrum, varied wavelength with intense plused light. Which exposure to skin's surface directly, selective effect on subcutaneous abnormal pigment and abnormal vascular.It will abnormal pigment cell decomposition, close abnormal capillary. Meanwhile, intense pulsed light is to absorbed collagen moisture and to produce thermal effect. Finally stimulating the proliferation of collagen and made the rearrangment of collagenous tissue , achieving the purpose of skin rejuvenation,wrinkle removal and blood vessel removal. |
Sparse hair growth | Higher fluence |
Darker Skin color | Longer pulse delay & Lower fluence |
Lighter skin color | Shorter pulse delay & Higher fluence |
More sensitive skin | Lower fluence |
Less sensitive skin | Higher fluence |
Start with a low fluence (i.e. 25 J/cm22 2
Please note that treatment over bony areas such as the malar area, forehead and shins produces more discomfort so reduce the fluence by 2-3 joules. When treating very densely pigmented areas reduce fluence by 2-3 joules.
1.11 Specification
Operation Inteface | 8 inch TFT Screen |
Wavelength | 750nm(E-Light) |
Working Mode | Multi-Pulse&Single-Pulse mode E-Light Working |
Spot Size | 15X50mm; |
Energy | 1-26J/cm2(E-Light) |
Pulse Width | 1-9.9ms |
Pulse Amount | 1-6 |
Handle | 1X750nm(E-Light) |
E-Light Drive Power | 2000W |
Contious shottingnon-stop | 14 working stand-by working |
Handpiece lifetime | 2000,000 shots times for each handle |
Weight | 48KG |
1.12 operation interface:
Technological Advantages
1. Large vertical equipment, huge color touch screen, exalted and noble.
2. Combining three technologies, intense pulsed light, radio frequency and laser, having more complete functions.
3. Latest plug and play butt joint, separate water and electric design, more secure and easy to install.
4. Perfect combine of large capacity stainless steel tank and industrial radiator, it provide water cycle cooling system which satisfies customers’ continuous treatment demand.
5. Nine operating languages suit to different colleagues in different countries.
6. Water flow and temperate self- testing system and self-correcting system to guarantee safe operation.