2016 new design IPL/Laser IPL machine/permanent IPL hair removal

2016 new design IPL/Laser IPL machine/permanent IPL hair removal

USD $1 - $1,450 /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
Hongkong
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

IPL+ RF:
Yes
Certification:
CE,RoHS,ISO
Place of Origin:
Guangdong, China
Brand Name:
LINGMEI
Model Number:
TSL-1121C
Feature:
Acne Treatment, Blood Vessels Removal, Dark Circles, Face Lift, Pigment Removal, Pigmentation Correctors, Skin Rejuvenation, Skin Tightening, Wrinkle Remover

Guangzhou Lingmei Electronic Technology Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer,Trading Company,Distributor/Wholesaler
Guangzhou Guangdong China
Main Products: cryolipolysis machine ,No-Needle Mesotherapy Machine ,Electrostimulaiton Machine ,Cavitation Machine ,RF Slimming Machine

Product Details

Product name:2016 new design IPL/Laser IPL machine/permanent IPL hair removal

2016 new design IPL/Laser IPL machine/permanent IPL hair removal 

E-Light is the first and only technology that combines optical (light) energy. Gentle pulses of targeted energy isolate the treatment area and leave the surrounding skin free from potentially harmful side effects. In addition to permanent hair reduction for most hair colors and skin types, E-Light effectively and comfortably treats rosacea, spider veins; skin imperfections caused by sun damage, age spots, enlarged pores and uneven skin tones. A series of E-Light treatments will leave your skin smoother clearer with a tighter more youthful appearance.

2016 new design IPL/Laser IPL machine/permanent IPL hair removal

1.1 Device Structure of laser ipl machine

This device is composed of three parts: (1) main unit, (2) control panel, and (3) the E-Light treatment handpiece

The control panel includes the color 8.4” LCD screen, the power switch and emergency shut off switch. The LCD screen shows the work mode and the parameters of the system.

1.2 Medical Use-Application Areas

1. Permanent hair removal

2. Skin rejuvenation

3. Reduction of pigmented lesions

4. Wrinkle removal

5. Acne Therapy

6. Freckle, vascular lesions and facial blemish removal

2016 new design IPL/Laser IPL machine/permanent IPL hair removal2016 new design IPL/Laser IPL machine/permanent IPL hair removal

1.3 Main Unit

The Main unit is the integral part of this system; it consists of the following parts.

1.The Power supply module: regulates electrical supply to the entire system.

2.The Control module: Regulates and coordinates the various components of the system for optimum performance.

3.The display module: Displays various information of the system and accept users instruction.

4.High current capacitors: Delivers adequate electrical energy to guarantee sufficient power during operation.

5.Cooling system: Maintains a stable thermal environment for optimum performance.

1.4 The E-Light+RF treatment handpiece

The E-Light handle consists of a (1) Cable housing: this contains the power cable, liquid coolant tubing, control data cable; (2) E-Light head: this houses the control switch, flash lamp, sapphire crystal, filter piece and electronic semi-conductor cooling system.

Pressing on the trigger on the E-Light treatment head discharges the flash lamp at the settings as displayed on the control panel. Pushing down the foot switch like-wise discharges the device (on selected models only). The supplied sapphire crystal measures 12mmx 35 mm and is superior in both clarity and longetivity, thereby increasing both the efficiency of the flash lamp and lifespan of the treatment head. It is very important to keep the sapphire crystal clean. Make sure to clean this with a soft cloth after each treatment. A disinfectant such as alcohol can be used between treatments. Dried gel on the crystal filter will reduce efficiency of the flash lamp. Replace the plastic guard over the filter to prevent damage. In the event that the sapphire crystal is damaged (i.e. nicked or cracked) contact your dealer immediately.

2016 new design IPL/Laser IPL machine/permanent IPL hair removal2016 new design IPL/Laser IPL machine/permanent IPL hair removal

1.5 Protection Glasses

One pair of protective glasses is provided with the device. The opaque glasses are to be worn by the patient and the filtered 430-1200 nm glasses are to be worn by the operator. Despite wearing the protective glasses, avoid staring directly into the intense pulses of light during the treatment. Only personnel wearing protective glasses may be allowed to observe the treatment.

1.6 Light-coupling Gel

The light-coupling gel is used to maximize the conduction of light from the flash lamp to the skin. The light-coupling gel must be clear/transparent and not colored/tinted. Colored gels absorb light therefore reducing the effectiveness of the treatment. The light-coupling gel must be chilled but not frozen. Frozen gel diffuses the light emitted by the flash lamp reducing its efficacy. Light-coupling gels must be non-alcohol based. The E-Light produces considerable heat; flammable material must be kept clear of the treatment area.

2016 new design IPL/Laser IPL machine/permanent IPL hair removal2016 new design IPL/Laser IPL machine/permanent IPL hair removal2016 new design IPL/Laser IPL machine/permanent IPL hair removal

1.7 The Environment Requirements of laser ipl machine:

Working temperature scope           : +15~+30°C

Relative humidity scope                  : 30%~80%

Atmospheric pressure barometric    : 86kpa -106kpa

The store environment temperature : +5°C ~+55°C

Power supply                                   : 230V AC , 50/60Hz,  10A;

                                                          or 115V AC , 50/60Hz, 20A

 

1.8 detailed list of equipment of this IPL hair removal:

1.Main host

2.The E-Light handpiece X1

3.Protective glassesX1

4.Protective goggleX1

5.Power cableX1

6.Foot switchX1

7.FunnelX1

8.Plastics hoseX1

9.Key X2

2016 new design IPL/Laser IPL machine/permanent IPL hair removal

2016 new design IPL/Laser IPL machine/permanent IPL hair removal

2016 new design IPL/Laser IPL machine/permanent IPL hair removal

1.9 System Trouble Shooting

No power

Check power cable

Check circuit breaker / fuse

Check key switch

Disengage the emergency cut off switch by rotating towards the direction of the arrows indicated

Notify your distributor

Key pads are none responsive

Please contact the dealer.

System failed to initialize

Not enough power, please check main power supply.

Please contact the dealer.

Malfunction of flash lamp on the E-Light treatment head

The treatment head / flash lamp has reached its maximum life span (300,000) shots. Replace the treatment head

Suggset you to replace the handle after 300,000 shots , or the treatment effect will not be good

The E-Light treatment head is probably damaged, please change the E-Light treatment head or contact the dealer.

The E-Light treatment head is leaking

O-Ring for faucet is likely to lose, Pull out the treatment handpiece, then take out O-Ring from accessories and push into water conduit.

 

The E-Light treatment head is probably damaged, please change the E-Light treatment head or contact the dealer.

The treatment handle is warm

The system is designed for continued used for up four hours in optimal environmental temperature and humidity.

 

Always place the system on standby mode while awaiting treatment. The system might have been left on for an extended period. Turn the unit off, let it cool down for half an hour then re- start

 

Contact the dealer.

The power of The E-Light treatment head has weakened

The treatment head has nearly reached its maximum life span the fluence can be adjusted by a few joules to compensate.

 

 

1.10 Parameter Selection

 

Dark hair

Shorter pulse width

Light hair

Longer pulse width

Deep hair

Longer pulse width

Superficial hair

Shorter pulse width

Thick hair

Longer pulse delay & lower fluence

Thin hair

Shorter pulse delay & higher fluence

Dense hair growth

Lower fluence

Sparse hair growth

Higher fluence

Darker Skin color

Longer pulse delay & Lower fluence

Lighter skin color

Shorter pulse delay & Higher fluence

More sensitive skin

Lower fluence

Less sensitive skin

Higher fluence

 

Start with a low fluence (i.e. 25 J/cm2). Do a test shot in an inconspicuous area. Evaluate patient response then gradually increase the fluence by increments of 3 J/cm2 when a fluence of around 30 J/cm2 is achieved, increase by increments of 1 or 2 depending on patient’s response. We strongly recommend that for the 1st treatment, the fluency level be set initially at least 8 to 10 joules/sq cm. below the suggested level of treatment parameter sheet.

 

Please note that treatment over bony areas such as the malar area, forehead and shins produces more discomfort so reduce the fluence by 2-3 joules. When treating very densely pigmented areas reduce fluence by 2-3 joules.

 

1.11 Specification of laser ipl machine:

Operation Inteface

8 inch TFT Screen

Wavelength

750nm(E-Light)    

Working Mode

Multi-Pulse&Single-Pulse mode E-Light Working

Spot Size

15X50mm;

Energy    

1-26J/cm2(E-Light)

Pulse Width

1-9.9ms

Pulse Amount

1-6

Handle

1X750nm(E-Light)  

E-Light Drive Power

2000W

Contious shottingnon-stop

14 working stand-by working

Handpiece lifetime

2000,000 shots times for each handle

Weight

48KG

 

1.12 operation interface:

2016 new design IPL/Laser IPL machine/permanent IPL hair removal

2016 new design IPL/Laser IPL machine/permanent IPL hair removal 2016 new design IPL/Laser IPL machine/permanent IPL hair removal

Contact Supplier

Ms. Mary TSL Manager Chat Now
Telephone
86-20-28973290
Mobile
15018465983
Fax
86-20-62351387
Address
Room B45,4th Floor NO.306 Jiefang Zhong Road,Yuexiu Area,Guangzhou,China Guangzhou,Guangdong

You May Like

New Products

Find Similar Products By Category

Beauty & Personal Care > Beauty Equipment > IPL Machine
Categories
Hi~