portable holter ecg/ekg device factory price
USD $1 - $500 /Piece
Min.Order:10 Pieces
Guangzhou Joyful Technology Co., Ltd.
portable holter ecg/ekg device factory price
As a multi-functional ECG machine, mobile ECG include functions about auscultation, ECG acquisition, SpO2 and pulse rate monitoring. This instrument has ECG waveform recording and playback; oxygen value and pulse rate value could be stored and data will be uploaded to a computer to facilitate analysis of the disease.
Applicable For: hospital, community health, oxygen bar, family, before and after exercising, etc
Main function
Compact and portable, easy to use
Display of ECG waveform, heart rate, SpO2, pulse rate, pulse waveform
Earphone output and 16 steps volume adjustable
Alarm for SpO2 and pulse rate exceeding limits
Real-time detecting, TF card data record and review
Real-time clock
Recorded data can be transferred to a PC
PC analysis software
Low power consumption
Technical specifications
Technical specifications | Temperature | Relative Humidity | Atmospheric pressure | |
Environment Transport and storage | -10℃~ +50℃
| 10% ~ 95% | 50kPa ~ 106Kpa | |
Working environment | 5℃~40℃ | 20%~80% | 70kPa~106kPa | |
Battery type | Working-viktageL | Power | LCD display | Continuous running time |
charging lithium battery | DC3.6V~DC4.2V | ≤120mA | 2.4"TFT, 320*240 Pixels | 7hours |
Physical Characteristics | Size:
| 110(length)*60(wicth)*15(height)mm | Weight: | 100(including lithium battery) |
Main Parameters
(1) Measurement of auscultation volume
Heart sound range: 20Hz~230Hz
Lung sound range: 100Hz~800Hz
Heart lung combination sound range: 20Hz~800Hz
(2) Measurement of Heart Rate
Range: 30bpm~300bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(3) Measurement of SpO2
range: 0%~100%
resolution: 1%
accuracy: When the SpO2 measurement range is 70%~100%, the permission of absolute error is ±2%. Below 70% unspecified.
(4) Measurement of pulse rate
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(5) Measurement Performance in Weak filling Condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%(select larger).
(6) Resistance to surrounding light
The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%.
Advantages
Easy to operate.
Newest piezoelectric sensors
Button volume control
3 types auscultation mode: heart sound, lung sound, heart and lung sound
Color TFT, resolution: 160*128
ECG waveform display
SpO2, pulse oximeter display
3.7V lithium battery
product display
Packing&Shipping
All items are exported by standard wooden packing with alloy frame. Machine will be complete accommodating in it properly.