Maternal fetal heart monitor portable ecg holter
USD $1 - $230 /Piece
Min.Order:10 Pieces
Guangzhou Joyful Technology Co., Ltd.
Maternal fetal heart monitor portable ecg holter
As a multi-functional ECG machine, mobile ECG include functions about auscultation, ECG acquisition, SpO2 and pulse rate monitoring. Useful in disease analysis.
Applicable For: hospital, community health, oxygen bar, family, before and after exercising, etc.
Main Feature
Auscultation sounds output
ECG waveform display
HR display
ECG data sampling, waveform playback.
External Integrated oxygen probe for SpO2 monitoring
SpO2 value display
Pulse waveform, PR display
Pulse rate sound prompt
SpO2, PR data saving, upload
Power display
Exceed limits alarm and low power alarm
Technical specifications
Technical specifications |
Physical Characteristics |
Size: 110(length)*60(wicth)*15(height)mm Weight:100(including lithium battery) |
Environment Transport and storage |
Temperature: -10℃~ +50℃ Relative Humidity: 10% ~ 95% Atmospheric pressure: 50kPa ~ 106Kpa |
Working environment |
Temperature: 5℃~40℃ Relative Humidity: 20%~80% Atmospheric pressure: 70kPa~106kPa |
Battery type |
charging lithium battery |
Working-viktageL |
DC3.6V~DC4.2V |
Power |
≤120mA |
LCD display |
2.4"TFT, 320*240 Pixels |
Continuous running time |
7hours |
Main Parameters
(1) Measurement of auscultation volume
Lung sound range: 100Hz~800Hz
Heart lung combination sound range: 20Hz~800Hz
(2) Measurement of Heart Rate
Range: 30bpm~300bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(3) Measurement of SpO2
range: 0%~100%
resolution: 1%
accuracy: When the SpO2 measurement range is 70%~100%, the permission of absolute error is ±2%. Below 70% unspecified.
(4) Measurement of pulse rate
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(5) Measurement Performance in Weak filling Condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%(select larger).
(6) Resistance to surrounding light
The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%.
Product Dsiplay
Our Service
We offer 1 year free maintenance for this machine
We guarantee quick and efficient service and maintenance of our device security solutions around the world. We ensure that we will be there whenever or wherever you need us, 24 hours a day, 365 days a year. Like all Onity solutions, our products are backed by a commitment to provide superior global service with local support. we can help you work and reach your goals.
Packing&Shipping
All items are exported by standard wooden packing with alloy frame. Machine will be complete accommodating in it properly.