portable neonatal ecg/spo2 sensor
USD $1 - $230 /Piece
Min.Order:10 Pieces
Guangzhou Joyful Technology Co., Ltd.
portable neonatal ecg/spo2 sensor
PM-8000 integrates the functions of, ECG collection, SpO2, auscultation and PR inspection. The product is applicable for family, hospital, private Clinique, community medical treatment. Etc.
Main function
Auscultation sounds output
ECG waveform display
HR display
ECG data sampling, waveform playback.
External Integrated oxygen probe for SpO2 monitoring
SpO2 value display
Pulse waveform, PR display
Pulse rate sound prompt
Spo2, PR data saving, upload
Power display
Exceed limits alarm and low power alarm
Advantages
Easy to operate.
Newest piezoelectric sensors
Button volume control
3 types auscultation mode: heart sound, lung sound, heart and lung sound
Color TFT, resolution: 160*128
ECG waveform display
SpO2, pulse oximeter display
3.7V lithium battery
Main Parameters
(1) Measurement of auscultation volume
Lung sound range: 100Hz~800Hz
Heart lung combination sound range: 20Hz~800Hz
(2) Measurement of Heart Rate
Range: 30bpm~300bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(3) Measurement of SpO2
range: 0%~100%
resolution: 1%
accuracy: When the SpO2 measurement range is 70%~100%, the permission of absolute error is ±2%. Below 70% unspecified.
(4) Measurement of pulse rate
Range: 30bpm~250bpm
Resolution: 1bpm
Accuracy: ±2bpm or ±2%(select larger)
(5) Measurement Performance in Weak filling Condition
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2%(select larger).
(6) Resistance to surrounding light
The deviation between the value measured in the condition of man-made light and indoor natural light and that of darkroom is less than ±1%.
Technical specifications
Physical Characteristics |
Size: 110(length)*60(wicth)*15(height)mm Weight:100(including lithium battery) |
Environment Transport and storage |
Temperature: -10℃~ +50℃ Relative Humidity: 10% ~ 95% Atmospheric pressure: 50kPa ~ 106Kpa |
Working environment |
Temperature: 5℃~40℃ Relative Humidity: 20%~80% Atmospheric pressure: 70kPa~106kPa |
Battery type |
charging lithium battery |
Working-viktageL |
DC3.6V~DC4.2V |
Power |
≤120mA |
LCD display |
2.4"TFT, 320*240 Pixels |
Continuous running time |
7hours |
Packing&Shipping
All items are exported by standard wooden packing with alloy frame. Machine will be complete accommodating in it properly.
Choose Me
OEM:Yes
Experienced for many years:Yes
Exhibition Attended:Yes
Research&Develop Team:Yes
CE Certificate:Yes
Custom Personalized Service :Yes
High Quality:Of course!
Click Me, More Surprise