Micro Duct Connectors---Straight Connector
USD $1 - $1.8 /Piece
Min.Order:500 Pieces
Fiber Cable Solution Technology Co., Ltd.
FCST132303 FCST HDPE Micro duct 7/3.5 mm 7 ways tube bundle direct buried for air blowing solution
FCST132 FCST HDPE Micro Duct For Fiber Optical Cable DB Tube Bundle, Direct Bury Duct
Micro Duct Closure For Tube Distribution, Duct Joint Closure For Micro Duct
FCST1410601 FCST ABF4cores Fiber Unit For Air Blowing Cable 12 cores
Micro Duct Connectors---Straight Connector
1. Part List
Part Name | Type | Blow Pressure | Pull Strength For HDPE tube | Pull Strength For LSZH tube | Life time |
5 mm DI connector | DI-5 | >18bar | ≥350N | >150N | 10 Years |
7 mm DI connector | DI-7 | >18bar | ≥350N | >150N | 10 Years |
10 mm DI connector | DI-10 | >18bar | ≥350N | >150N | 10 Years |
12 mm DI connector | DI-12 | >18bar | ≥350N | >150N | 10 Years |
14 mm DI connector | DI-14 | >18bar | ≥350N | >150N | 10 Years |
2. Scope
The scope of this specification is to describe the construction and the requirements of the components used in the access network where the micro duct is cut and needs to be blanked off.
2.1 Connector
The connectors shall have the necessary sealing arrangement to operate safely at blowing pressures of 18 Bar and protect the inner cavity against significant ingress of mud, sand and debris.
2.2 Material
The following performance tests will demonstrate satisfactory design performance and material selection will ensure good lifetime and stability of performance characteristics.
3. Testing
3.1 Operating testing
The Microduct Connectors shall with stand the following mechanical and environmental tests at ambient temperature of -10~30ºC,the pipe material is PE, PU or Nylon, the testing use the liquid or the clean compressed air after filtrating .
3.2 Burst Pressure Test
The connectors shall be sealed well at internal pressures up to 25 Bar without sustaining damage, or permanent deformation, and shall remain connected to the duct. Pressure shall be increased through to failure of the connector or duct. The pressure and mode of failure shall be recorded.
4. Design Lifetime
The connector shall meet all performance requirements over a minimum period of 10 years at the normal condition.
Exhibition:
•Packing: By carton
•Shipping: By air. By sea. By TNT. By DHL.By UPS etc.
ODM,Product training,FTTH solution consultant,?After?sale?service,Fiber blowing solution consultant, Fiber tools&toolkits consultant
•Production Capacity: We can provide 50,000pcs per week
•R&D department: 10 designer
•The Exhibition experience:ECOC,OFC,NETCOM,Local Exhibition
•Cooperation customers:CMCC,Huawei,Tyco,ZTE,3M, Dura-Mine,GM,MG...
•Transaction Term: EXW,FOB,CNF,CIF
•Payment Term: 100% T/T in advance