encolsed dual output switching power supplies D-100-B
Negotiable /Piece
Min.Order:1 Piece
Zhejiang Lierd Relays Enterprise Co., Ltd.
encolsed dual output switching power supplies D-100-B
1.100W dual output switching power supply
2.CE/ISO9001 certificate
3.Competitived price,good quality
4.Samples available
Model | D-100A | D-100B | ||
CH1 | CH2 | CH1 | CH2 | |
DC output voltage | 5V | 12V | 5V | 24V |
Output voltage range(Note:2) | ±2% | ±6% | ±2% | ±7% |
Rated output current | 15A | 2A | 15A | 1A |
Output current range | 1-15A | 0.3-2A | 1-15A | 0.2-1A |
Wave and noise(Note:3) | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Inlet stability(Note:4) | ±0.5% | ±1% | ±0.5% | ±1% |
Load stability(Note:5) | ±0.5% | ±5% | ±0.5% | ±6% |
DC output power | 98W | 99W | ||
Efficiency | 78% | 80% | ||
Adjustable range for DC voltage | CH1; +10, -5% | CH1; +10, -5% | ||
AC input voltage range | 88~132VAC/170~264VAC selected by switch 47~63Hz;120~370VDC | |||
Input current | 2.8A/115V 1.6A/230V | |||
AC inrush current | Cold-start current 35A | |||
Leakage current | <3.5mA/240VAC | |||
Overload protection | 105%~150% Type: pulsing hiccup shutdown Reset: auto recovery | |||
Over-voltage protection | CH1: 5.75~6.75V | |||
Temperature coefficient | ±0.03%/°c(0~50°c)ON+5V | |||
Setup, rise , hold up time | 200ms,50ms, 20ms at full load | |||
Vibration | 10~500Hz, 2G 10min,/1cycle, Period for 60min, Each axes | |||
Withstand voltage | Input and output internal: Input and encolsur: 1.5KvAC, Output and enclosure: 0.5KvAC | |||
Isolation resistance | Input and output internal: Input and enclosure, Output and enclosure:500VDC/100MΩ | |||
Working temperature and humidity | -10°c~+60°c(Refer to output derating curve), 20%~90%RH | |||
Overall dimension | 199×110×50mm | |||
Weight | 0.85Kgs | |||
Safety standards | UL 1012, TUV EN60590(IEC950, UL 1950) Apporved | |||
EMC standards | CISPR22(EN55022)class B, IEC801-2,3,4 IEC555-2 Verification | |||
Note: 1. The testing condition for the paramenter above is: 230VAC input, rated load, 25°c 70% RH. Temperatuer. 2. Error: include the setting error, line stability and load stability.(Note:5). 3. Wave test: adopting "A12" double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting. 4. Inler woltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage. 5. Load stability test: The load is from 0% to 100%. 6. Total output canba maxinum Current, total load can not exceed the maxium output power. |