yudian 4 20ma pt100 temperature transmitter
USD $40 - $100 /Piece
Min.Order:1 Piece
Xiamen Yudian Automation Technology Co., Ltd.
I. yudian 4 20ma pt100 temperature transmitter Main Features:
II. yudian 4 20ma pt100 temperature transmitter Technical Specification:
Input type | Thermocouple: K, S, R, E, J, T, B, N, WRe5-WRe26 RTD: Pt100, Cu50 Linear voltage: 0~20mV, 0~60mV, 0~100mV, 0~1V, 0.2~1V etc. |
Instrument Input range | K(-50~+1300 ), S( ℃ -50~+1700 ), R( ℃ -50~+1700 ), T( -200~+350℃), E(0~1000 ℃), J(0~1200℃), B(0 ~1800 ℃), N( -50~+1300℃), WRe5 ℃ -WRe26(0~2300℃), Pt100(-200~+900)℃, Cu(-50~+150)℃ Linear Input: -9990~+30000 units defined by user. |
Retransmission accuracy | 0.3%FS ± 1 digit (including input and output error) |
Output Specification | can be freely defined in the range of 0~22mA with maximum output voltage ≥11V |
Temperature drift | ≤0.015%FS /℃ (including the temperature drift of input and output) |
Electromagnetic compatibility (EMC) | ±4KV/5KHz according to IEC61000-4-4 (EFT); 4KV according to IEC61000-4-5. |
Isolation withstanding voltage | voltage between power, signal input and output terminals ≥2300VDC; between inputs or 2 outputs ≥200VDC |
Power supply | 100~240VAC, -15%, +10% / 50Hz; or 24VDC/AC. |
Power consumption | ≤3W |
Operating Ambient | Temperature -10~+60℃; humidity ≤90%RH |
Note 1: B thermocouple obtains the above measurement accuracy only at the range of 400~1800℃ . Its measurement from 60~400℃ is less accurate. |
III. yudian 4-20ma converter 4-20ma transmitter Front panel and Operation:
The parameters of AI-7021D5 can be set by an external E8 display which can be used to configure AI-7021D5 at the initial set up, as well as remain connected to AI-7021D5 and serves as an external display.
The functions of the parts of E8 external display panel is as below:
1. Upper display window, displays PV of channel 1 or parameter code, etc.
when display keep flashing or the reading abnormal, please check the input specification set correct or not.
2. Lower display window, displays PV of channel 2 or parameter value.
When display keep flashing or the reading abnormal, please check the input specification set correct or not.
3. Setup key, for accessing parameter table and conforming parameter modification.
4. Data shift key.
5. Data decrease key.
6. Data increase key.
(E8 handheld display) (AI-7021D5)
IV. yudian 4-20ma converter 4-20ma transmitter Layout of Terminals and Indication Lights and Wiring:
Terminal 1 and 2 are for power supply of 100-240VAC or 24VAC/DC.
Terminal 5 and 6 are the positive and negative pole of channel 1 current retransmission output.
Terminal 7 and 8 are the positive and negative pole of channel 2 current retransmission output.
Terminal 14~16 are for channel 1 input.
Terminal 10~12 are for channel 2 input.
1) Factory with 25 years experience.
2) Quick delivery ( within 3~5 working days).
3) Retail/Wholesale/OEM/ODM available .
We expect to cooperate with machinery manufacturers,
better price for bulk order.
4)We provide after sales service and technical assistance as per the
customers requirement and needs.
1. How long will you give me the reply?
we will contact you in 2 hours as soon as possible
2. Could I get samples of yudian 4 20ma pt100 temperature transmitter ?
Yes,we have products in stock ,so you can get the samples quickly.
3. How about the quality of yudian 4 20ma pt100 temperature transmitter ?
We have the certification of ISO,CE and ROSH,we could send the certification test of our company to you.
4. Could I visit your factory?
Of course,if you need we will help you to visit our factory.
5. If I have paid,when will you help me to produce?
We will start producing immediately after receiving the payment.