AI-526 Heating and Cooling Dual Output Temperature Controller
AI-526 Heating and Cooling Dual Output Temperature Controller
AI-526 Heating and Cooling Dual Output Temperature Controller
AI-526 Heating and Cooling Dual Output Temperature Controller
AI-526 Heating and Cooling Dual Output Temperature Controller
AI-526 Heating and Cooling Dual Output Temperature Controller

AI-526 Heating and Cooling Dual Output Temperature Controller

USD $50 - $60 /Unit

Min.Order:5 Units

Supply Ability:
500000 Unit / Units per Month
Port:
XIAMEN port
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Brand Name:
YUDIAN
Model Number:
AI-526
Usage:
Industrial
Theory:
Temperature Controller
Accuracy:
0.25%FS±0.01°C

Xiamen Yudian Automation Technology Co., Ltd.

Credit Member 4 years
Business Type: Manufacturer
Xiamen Fujian China
Main Products: Temperature Controller ,Indicator ,SSR ,Paperless Recorder ,data loger

Product Details

AI-526 Heating and Cooling Dual Output Temperature Controller

 

 

Product Description

AI-526 Heating and Cooling Dual Output Temperature Controller

 

 

AI-526 Heating and Cooling Dual Output Temperature Controller

 

Main Features for AI-526 Heating and Cooling Dual Output Temperature Controller

  • Use digital calibration technology for input measurement with input measurement accuracy F.S.0.25%, Support standard thermocouples and RTDs, maximum resolution is 0.01℃.
  • Use advanced artificial intelligent control algorithm, no overshoot and with the function of auto tuning (AT) and self-adaptation.
  • Use advanced modular structure, conveniently providing plentiful output options, able to satisfy the requirements of various applications, make quick delivery and convenience the maintenance of the instrument.
  • Friendly and customized operating interface leads to quick and easy to operate. Parameter can be promoted to immediate operator access in Field Parameter Table or password protected in Full Parameter Table.
  • With worldwide power supply of 100-240VAC or 24VDC and various installation dimensions for users to choose.
  • ISO9001,CE and UL 61010-1 certified, achieving world class level of quality, anti-interference ability and safety. 

 

Technical Specifications for AI-526 Heating and Cooling Dual Output Temperature Controller

 

1. Input type (Either of below specifications can be used selectively in the one instrument)
Thermocouple: K, S, R, E, J, N, T, B, WRe3-WRe25, WRe5-WRe26.
Resistance temperature detector: Cu50, Pt100
Linear voltage: 0~5V, 1~5V, 0~1V, 0~100mV, 0~20mV, 0~500mV etc.
Linear current (external precise shunt resist needed): 0~10mA,0~20mA, 4~20mA, etc.
Extended input (install I4 module in MIO) : 0~20mA, 4~20mA or two line transmitter.
Optional: apart from the above-mentioned Input type, an additional type can be provided upon request. (Graduation index is needed)
2. Instrument Input range
K(-50~1300℃), S(-50~1700℃), R(-50~1700℃), E(0~800℃), J(0~1000℃), N(0~1300℃), T(-200~+350℃), B(200~1800℃)
Cu50(-50~+150℃), Pt100(-200~+600℃)
Linear Input: -9990~30000 defined by user
3.Measurement accuracy: 0.25%FS ± 1 measurement unit
4.Resolution: 0.1℃ for K, E, T, N, J, Cu50, Pt100; 1℃ for S, R
5.Temperature shift: ≤0.015%FS /℃ (typical value is 80ppm/℃)
6.Sampling period: read A/D converter 8 times per second
7.Response time: ≤0.5s ( when digital filter parameter FILt=0)
8.Alarm function: High limit, low limit, deviation high limit and deviation low limit; providing the function of alarm blocking at the beginning of power on.
9.Control period: 0.24~300.0 seconds selectable, and it should be integer times of 0.5 second.
10. Control mode:
On-off control mode (dead band adjustable)
Standard PID with auto tuning
AI PID with auto tuning, adopting artificial intelligence algorithm.
11. Output mode (modularized):
Relay output (NO+NC): 250VAC/2A, 30VDC/2A, 250VAC/1A and 30VDC/1A
TRIAC no contact discrete output (NO or NC): 100~240VAC/0.2A (continuous), 2A (20mS instantaneous, repeat period≥5s)
SSR Voltage output: 12VDC/30mA (used to drive SSR).
Thyristor zero crossing trigger output: Can trigger TRIAC of 5~500A, a pair of inverse paralleled SCRs or SCR power module.
Linear current output: 0~20mA, 4~20mA can scaling by user. (Output voltage : X3≥10.5V; X5≥7V maximum load resistor 500ohm, output precision 0.2%FS)
12. Electromagnetic compatibility (EMC): ±4KV/5KHz according to IEC61000-4-4; 4KV according to IEC61000-4-5.
13. Isolation withstanding voltage
Between power, relay contact or signal terminals ≥2300VDC;
Between isolated electroweak terminals ≥600V
14.Power supply: 100~240VAC, -15%, +10% / 50-60Hz; 120~240VDC; or 24VDC/AC, -15%, +10%.
15.Power consumption: ≤5W
16. Operating Ambient:  Temperature 0~60℃; humidity ≤90%RH
17.Front panel dimension:  96×96mm, 160×80mm, 80×160mm, 48×96mm, 96×48mm, 48×48mm, 72×72mm
18.Panel cutout dimension: 92×92mm, 152×76mm, 76×152mm, 45×92mm, 92×45mm, 45×45mm, 68×68mm
19.Depth behind mounting surface: ≤100mm

 

 

Ordering Code Definition for AI-526 Heating and Cooling Dual Output Controller

 

Advanced modularized hardware design is utilized for AI series instruments. There are maximum five module slots: multi-function input/output (MIO), main output (OUTP), alarm (ALM), auxiliary output (AUX) and communication (COMM). The modules can be purchased together or individual, and can be assembled freely. The input type can be set to thermocouple, RTD, or linear current/voltage.

 

The ordering code of AI-526/AI-526P (V8.2) series instrument is made up of 9 parts. For example:

                      AI-526     A    N    X3    L5    N    S4    -   24VDC  -  (F2)
                                  1         2     3     4      5      6     7                8             9


It shows that the model of this instrument is AI-526, front panel dimension is A size(96×96mm), no module is installed in MIO slot, X3 linear current output module is installed in OUTP (main output), ALM (alarm) is L5 (dual relay contact output module), no module is installed in AUX (auxiliary output), S4 (RS485 communication interface module) is installed at COMM , and the power supply of the instrument is 24VDC, an extended input type (F2 radiation type pyrometer) is available.

 

The following is the meanings of the 9 parts:


Part 1 Shows the model of the instrument

AI-526 Economical type instrument with measurement accuracy 0.25%F.S. It adopts artificial intelligent control technology, and has the functions of control, alarm, retransmission and communication.
AI-526P Base on AI-526 added 30 segments programmable functions.

Part 2 Shows the front panel dimension

SizeFront Panel (W*H)Cut Out (W*H)Depth Behind Mounting SurfaceLight Bar
A96*96mm92*92mm

100mm

 
A296*96mm92*92mm

100mm

25 segments and 4 level
B160*80mm 152*76mm 100mm  
C80*160mm152*76mm100mm 
C380*160mm152*76mm100mm50 segments and 2 level
D72*72mm68*68mm95mm 
D248*48mm45*45mm95mm 
E48*96mm45*92mm100mm 
F96*48mm92*45mm100mm 
E548*96mmRail mounted110mm 

Part 3 Shows the module type of multiple functions I/O (MIO).

Selectable modules are I2, I4, K3 and V, etc. N means no module been installed.
Part 4 Shows the module type of main output (OUTP).

Selectable modules are L1, L2, L4, W1, W2, G, K1, K3, K5, K6, X3, X5, etc.
Part 5 Shows the module type of alarm (ALM).

Selectable modules are L0, L2, L4, L5, W1, W2, G, etc.
Part 6 Shows the module type of auxiliary output (AUX).

Selectable modules areL0, L1, L2, L4, L5, W1, W2, G, K1, X3, X5, etc.

Part 7 Shows the module type of communication (COMM).

Selectable modules are S, S4, V, etc.

Part 8 Shows the power supply of the instrument.

If left blank, the power of the instrument is 100~240VAC. Added "24VDC" means the power supply of 20~32V DC or AC power

Part 9 Shows the optional extended graduation spec (If none, leave it blank).

AI-526 series instruments support many input types including popular thermocouples, RTDs, linear voltage, current and resistance inputs. If needed, an additional specification not mentioned in input type selection (InP) table can be extended.

 

 

 

AI-526 Heating and Cooling Dual Output Temperature Controller

 

AI-526 Heating and Cooling Dual Output Temperature Controller

 

 

Front Panel and Operation for AI-526 Heating and Cooling Dual Output Controller

 

AI-526 Heating and Cooling Dual Output Temperature Controller

 

Packaging & Shipping

You will get:

  1. A piece of temperature controller;
  2. A paper of user manual;
  3. 5-year warranty card and Quality Approval card;
  4. A lable of units;
  5. A pair of installaton brackets;
  6. Nice package carton box with Yudian logo.

 

More Products

AI-526 Heating and Cooling Dual Output Temperature Controller

 

 

Company Information

AI-526 Heating and Cooling Dual Output Temperature ControllerAI-526 Heating and Cooling Dual Output Temperature ControllerAI-526 Heating and Cooling Dual Output Temperature Controller

 

 

FAQ

 

AI-526 Heating and Cooling Dual Output Temperature Controller

  • Factory with 26 years experience.
  • Three to ten years warranty time.
  • Quick delivery ( within 3 working days).
  • Retail/ Wholesale/ OEM/ ODM available.
  • Better price for bulk order.
  • We provide after sales service and technical assistance as customers requirement and needs.

If you are interested in our products, please feel free to contact with us.

Contact Supplier

Ms. Yudian Xiamen Sales Manager Chat Now
Telephone
86-592-2632250
Mobile
0086 15359289892
Fax
86-592-5651630
Address
17 North Huoju Road, Xiamen Torch Hi-tech Industrial Development Zone, Xiamen Xiamen,Fujian

You May Like

New Products

Find Similar Products By Category

Measurement & Analysis Instruments > Temperature Instruments
Categories
Hi~