45W Triple Output Open Frame Power Supply PT-45 Series
USD $10 - $50 /Piece
Min.Order:1 Piece
Shenzhen Graigar Technology Co., Ltd.
45W Triple Output Open Frame Power Supply PT-45 Series
MODEL NO.: PT-45
Features:
MODEL | PT-45A | PT-45B | PT-45C | |||||||
OUTPUT | OUTPUT NUMBER | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 | CH1 | CH2 | CH3 |
DC VOLTAGE | 5V | 12V | -5V | 5V | 12V | -12V | 5V | 15V | -15V | |
RATED CURRENT | 3A | 2A | 0.3A | 3A | 2A | 0.3A | 3A | 1.6A | 0.3A | |
CURRENT RANGE | 0.4 ~ 5A | 0.2 ~ 2.5A | 0 ~ 0.5A | 0.4 ~ 5A | 0.2 ~ 2.5A | 0 ~ 0.5A | 0.4 ~ 5A | 0.2 ~ 2.3A | 0 ~ 0.5A | |
RATED POWER | 40.5W | 42.6W | 43.5W | |||||||
OUTPUT POWER (max.) | Rated output power for convection;52W with 18 CFM min.Forced air | |||||||||
RIPPLE & NOISE (max.) Note.2 | 50mVp-p | 120mVp-p | 50mVp-p | 50mVp-p | 120mVp-p | 100mVp-p | 50mVp-p | 120mVp-p | 100mVp-p | |
VOLTAGE ADJ. RANGE | CH1:4.75 ~ 5.5V | |||||||||
VOLTAGE TOLERANCE Note.3 | ±4.0% | ±7.0% | ±5.0% | ±4.0% | ±7.0% | ±5.0% | ±4.0% | ±7.0% | ±5.0% | |
LINE REGULATION | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | ±1.0% | ±2.0% | ±1.0% | |
LOAD REGULATION | ±3.0% | ±4.0% | ±1.0% | ±3.0% | ±4.0% | ±1.0% | ±3.0% | ±4.0% | ±1.0% | |
SETUP, RISE, HOLD TIME | 800ms, 20ms,60ms at full load | |||||||||
INPUT | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC | ||||||||
FREQUENCY RANGE | 47 ~440Hz | |||||||||
EFFICIENCY (Typ.) | 75% | 75% | 75% | |||||||
AC CURRENT | 1A/115VAC 0.7A/230VAC | |||||||||
INRUSH CURRENT (max.) | COLD START 15A/115VAC 30A/230VAC | |||||||||
LEAKAGE CURRENT | <0.5mA | |||||||||
PROTECTION | OVERLOAD | 53 ~ 75W rated output power | ||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
OVER VOLTAGE | CH1:5.75 ~ 6.75VDC | |||||||||
Protection type: Hiccup mode, recovers automatically after fault condition is removed | ||||||||||
ENVIRONMENT | WORKING TEMP. | -10 ~ +60ºC (Refer to output load derating curve) | ||||||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||||||
STORAGE TEMP., HUMIDITY | -20 ~ +85ºC, 10 ~ 95% RH | |||||||||
TEMP. COEFFICIENT | ±0.04%/ºC (0 ~ 50ºC) on +5V output | |||||||||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | |||||||||
SAFETY & EMC(Note.4) | SAFETY STANDARDS | Design refer to UL60950-1,TUV EN60950-1 | ||||||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | |||||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022 (CISPR22) Class B | |||||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; Light industry level, criteria A | |||||||||
OTHERS | MTBF | 288.1Khrs min. MIL-HDBK-217F(25ºC) | ||||||||
DIMENSION | 127*76*28mm (L*W*H) | |||||||||
PACKING | 0.21Kg;72pcs/17Kg/1.35CUFT | |||||||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. | |||||||||
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | ||||||||||
3.Tolerance: includes set up tolerance, line regulation and load regulation. | ||||||||||
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. | ||||||||||
5.Mounting holes M1 and M2 should be grounded for EMI purposes. |
EDITED BY JENA