Features:
MODEL | RS-150-3.3 | RS-150-5 | RS-150-12 | RS-150-15 | RS-150-24 | RS-150-48 | |
OUTPUT | DC VOLTAGE | 3.3V | 5V | 12V | 15V | 24V | 48V |
RATED CURRENT | 30A | 26A | 12.5A | 10A | 6.5A | 3.3A | |
CURRENT RANGE | 0 ~ 30A | 0 ~ 26A | 0 ~ 12.5A | 0 ~ 10A | 0 ~ 6.5A | 0 ~ 3.3A | |
RATED POWER | 99W | 130W | 150W | 150W | 156W | 158.4W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 80mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 3.2 ~ 3.5V | 4.75 ~ 5.5V | 11.4 ~ 13.2V | 14.25 ~ 16.5V | 22.8 ~ 26.4V | 45.6 ~ 52.8V | |
VOLTAGE TOLERANCE Note.3 | ±3.0% | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION Note.4 | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
LOAD REGULATION Note.5 | ±2.0% | ±1.0% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
SETUP, RISE, HOLD TIME | 800ms, 20ms, 28ms/230VAC, 1200ms, 30ms, 20ms/115VACat full load | ||||||
INPUT | VOLTAGE RANGE | 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC | |||||
FREQUENCY RANGE | 47 ~ 63Hz | ||||||
EFFICIENCY (Typ.) | 74% | 78% | 83% | 84% | 86% | 87% | |
AC CURRENT(Typ.) | 3A/115VAC 2A/230VAC | ||||||
INRUSH CURRENT (Typ.) | COLD START 40A/230VAC | ||||||
LEAKAGE CURRENT | <2mA / 240VAC | ||||||
PROTECTION | OVERLOAD | 110 ~ 150% rated output power | |||||
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||||||
OVER VOLTAGE | 3.8 ~ 4.45V | 5.75 ~ 6.75V | 13.8 ~ 16.2V | 17.25 ~ 20.25V | 27.6 ~ 32.4V | 55.2 ~ 64.8V | |
Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||||||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70ºC (Refer to output load derating curve) | |||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||||||
STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH | ||||||
TEMP. COEFFICIENT | ±0.03%/ºC (0 ~ 50ºC) | ||||||
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||||||
SAFETY & EMC(Note.6) | SAFETY STANDARDS | Design refer to UL60950-1,TUV EN60950-1 | |||||
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC | ||||||
EMI CONDUCTION & RADIATION | Compliance to EN55022(CISPR22) Class B | ||||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | ||||||
EMS IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61000-6-2 (EN50082-2) heavy industry level, criteria A | ||||||
OTHERS | MTBF | 244Khrs min. MIL-HDBK-217F (25ºC) | |||||
DIMENSION | 199*98*38mm (L*W*H) | ||||||
PACKING | 0.7Kg; 20pcs/15Kg/0.8CUFT | ||||||
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. | ||||||
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. | |||||||
3. Tolerance: includes set up tolerance, line regulation and load regulation. | |||||||
4. Line regulation is measured from low line to high line at rated load. | |||||||