SSN-11,35~80 Celsius degrees USB temperature data logger
Negotiable /Piece
Min.Order:30 Pieces
Xiamen Wellzion Electronics Co., Ltd.
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Model | SSN-10 | SSN-11 | |
Temperature | Measurement range | -35~80 ºC(-31~176 ºF) | -35~80ºC(-31~176ºF) |
Accuracy(Typ.) | ±0.5ºC(±0.9 ºF) | ±0.5ºC(±0.9 ºF) | |
Resolution | 0.1ºC / 0.2 º F | 0.1ºC / 0.2 ºF | |
Long Term Drift | Negligible | Negligible | |
LCD | √ | ||
Memory Capacity | 64KBytes(Total 32,000 readings for all channels) | ||
Save file formats | txt, xsl, csv, bmp, jpg | ||
Sample Rate | Can be selected from 10 seconds to 12 hours | ||
Start Method | Immediately, Start by button, and Start at date&time | ||
Stop Method | Stop when memory full, overwrite when memory full, stop by button, and stop until specified number of sample points finished | ||
Sample Mode | Instant(default), average, maximum and minimum This will decide how to dispose data at idle time between a sample interval | ||
Button | Software config to start logging bybutton, or clear and reset LED alarm when LED alarm is hold | ||
LED | Red&green LED: Logger Status indication(Include Delay to Start, Logging, Alarm, Finished) (Sofware can disable this two LED for saving power) Yellow LED: Low battery indication | ||
Alarm | User programmable high or low alarm limit for each channel(If necessary) LED alarm and hold | ||
Communication | Direct USB connection Need to install the driver provided on CD | ||
PC Software | DGraphTM software and USB driver required (Included on CD) (Compatible with Windows XP, Windows Vista, Windows 7&8(32 bit & 64bit Versions)) Use these software to setup, download, view graph and analyse data | ||
Power Supply | User replaceable 1/2AA 3.6V Lithium Battery 1200mAh NOTE: USB interface can supply power directly if necessary | ||
Battery Life | Approx. 2 Years @ 1 Minute Sample Rate Approx. 4 Years @ 10 Minute Sample Rate Approx. 8 Years without any sample task NOTE: It also Depends on ambient temperatures and using of LEDs | ||
Operating Range | 0 to 100%RH -35 to 80 ºC(-31 to 176 ºF) | ||
Storage Range | Recommended: 20 to 60%RH 10 to 50 ºC(50 to 122 ºF) | ||
Case Material | ABS, TPU, PC | ||
Mounting | Mounting bracket (Optional) or locking eyelet | ||
Standard Compliance | IP66 | ||
Dimentions | 123mm*37mm*23mm(4.8"*1.5"*0.9") | ||
Weight | Approx. 90 grams(3.19 oz) |
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Model | Measurement Parameters | Range | Accuracy (Typ.) | LCD Display | Readings | Sample Rate | Sensor Location | Battery Life (Years) |
SSN-10 | Temperature | -35~80°C | ±0.5°C(±0.9°F) | NO | 32000 | 2s to 12h | Internal | 3 |
SSN-11 | Temperature | -35~80°C | ±0.5°C(±0.9°F) | YES | 32000 | 2s to 12h | Internal | 3 |
SSN-10E | Temperature | -40~125°C | ±0.5°C(±0.9°F) | NO | 32000 | 2s to 12h | External | 3 |
SSN-11E | Temperature | -40~125°C | ±0.5°C(±0.9°F) | YES | 32000 | 2s to 12h | External | 3 |
SSN-12 | Temperature | -35~80°C | ±0.2°C(±0.4°F) | NO | 32000 | 2s to 12h | Internal | 3 |
SSN-13 | Temperature | -35~80°C | ±0.2°C(±0.4°F) | YES | 32000 | 2s to 12h | Internal | 3 |
SSN-12E | Temperature | -40~125°C | ±0.2°C(±0.4°F) | NO | 32000 | 2s to 12h | External | 3 |
SSN-13E | Temperature | -40~125°C | ±0.2°C(±0.4°F) | YES | 32000 | 2s to 12h | External | 3 |