Model | DSO8072E | DSO8102E | DSO8152E | DSO8202E |
Sample Modes | Real-Time Sample | |||
Normal | Normal data only | |||
Peak Detect | High-frequency and randon glith capture | |||
Average | Wavefom Average, selectable 4,8,16,32,64,128 | |||
Inputs Coupling | AC, DC, GND | |||
Inputs Impendance | 1MΩ±2% , 20pF±3pF | |||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | |||
Maximum Input Voltage | CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×) | |||
Horizontal System | ||||
Sample Rate Range | 1GS/s | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | 2M | |||
SEC/DIV Range | 4ns/div~2000s/div, in a 2, 4, 8 sequence | 2ns/div~2000s/div, in a 2, 4, 8 sequence | ||
Sample Rate and Delay Time Accuracy | ±50ppm over any ≥1ms time interval | |||
Vertical System | ||||
Bandwidth | 70MHz | 100MHz | 150MHz | 200MHz |
Rise Time at BNC( typical) | 5ns | 3.5ns | 2.3ns | 1.8ns |
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously | |||
Volts Range | 2mV/div to 100V/div at input BNC | |||
Math | +, -, *, /, FFT | |||
FFT | Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point | |||
Bandwidth Limit | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
Trigger System | ||||
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative | |||
Trigger Source | CH1, CH2, AC Line | |||
Trigger Modes | Auto, Normal, Single | |||
Coupling Type | DC, AC, HF Reject, LF Reject, Noise Reject | |||
Trigger Sensitivity | DC(CH1,CH2): AC; HF Reject; LF Reject | |||
Trigger Level Range | CH1/CH2: ±8 divisions from center of screen; | |||
Trigger Frequency Counter | ||||
Readout Resolution | 6 digits | |||
Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) | |||
Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth | |||
Multimeter Specification | ||||
Maximum Resolution | 6000 Counts | |||
DMM Testing Modes | Voltage, Current, Resistance, Capacitance, Diode & Continuity | |||
Maximum Input Voltage | AC: 600V DC: 800V | |||
Maximum Input Current | AC: 10A DC: 10A | |||
Input Impedance | 10MΩ | |||
Capacitance | 40nF~400μF | |||
Diode | 0V~2.0V | |||
On-off Test | < 10Ω | |||
Waveform Generator Mode | ||||
Frenquency Range | 1Hz(DC)~25MHz | |||
DAC Clock | 2K~200MHz adjustable | |||
Memory Depth | 4KSa | |||
Vertical Resolution | 12 Bits | |||
Stability | <30ppm | |||
Amplitude | ±3.5V Max. | |||
Output Impedance | 50 Ω | |||
Output Current | 50mA Ipeak=50mA | |||
System Bandwidth | 25M | |||
Harmonic Wave Distortion | -50dBc(1KHz), -40dBc(10KHz) | |||
General Specifications | ||||
Display Resolution | 640 horizontal by 480 vertical pixels | |||
Display Contrast | Adjustable (16 gears) with the progress bar | |||
Frequency(typical) | 1kHz | |||
Dimension | 260mm*220mm* 75mm | |||
Weight | 2.5KG(without Packing) |