DSO1152E,2 channel handheld oscilloscope,150MHz Bandwidth
Negotiable /Piece
Min.Order:1 Piece
Xiamen Wellzion Electronics Co., Ltd.
Model | DSO1072E | DSO1102E | DSO1152E | DSO1202E |
Sample Modes | Real-Time Sample | |||
Normal | Normal data only | |||
Peak Detect | High-frequency and randon glith capture | |||
Average | Wavefom Average, selectable 4,8,16,32,64,128 | |||
Inputs Coupling | AC, DC, GND | |||
Inputs Impendance | 1MΩ±2% ll20pF±3pF | |||
Probe Attenuation | 1X, 10X | |||
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | |||
Maximum Input Voltage | CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×) | |||
Horizontal System | ||||
Sample Rate Range | 1GS/s | |||
Waveform Interpolation | (sin x)/x | |||
Record Length | 2M | |||
SEC/DIV Range | 4ns/div~2000s/div, in a 2, 4, 8 sequence | 2ns/div~2000s/div, in a 2, 4, 8 sequence | ||
Sample Rate and Delay Time Accuracy | ±50ppm over any ≥1ms time interval | |||
Scanning Speed Range | 4ns/div to 8ns/div; (-8div x s/div) to 40ms; 20ns/div to 80μs/div;(-8div×s/div) to 40ms 200μs/div to 40s/div; (-8div×s/div) to 400s | 2ns/div to10ns/div; (-4div×s/div) to 20ms; | ||
Delta Time Measurement Accuracy (Full Bandwidth) | Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200 | |||
Vertical System | ||||
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously | |||
Volts Range | 2mV/div to 100V/div at input BNC | |||
Bandwidth | 70MHz | 100MHz | 150MHz | 200MHz |
Rise Time at BNC( typical) | 5ns | 3.5ns | 2.3ns | 1.8ns |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled | ±400V(100V/div-20V/div); ±50V(10V/div-5V/div); ±40V(2V/div-500mV/div); ±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div) | |||
Math | +, -, *, /, FFT | |||
FFT | Windows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point | |||
Bandwidth Limit | 20MHz | |||
Low Frequency Response (-3db) | ≤10Hz at BNC | |||
Trigger System | ||||
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative | |||
Trigger Source | CH1, CH2, AC Line | |||
Trigger Modes | Auto, Normal, Single | |||
Coupling Type | DC, AC, HF Reject, LF Reject, Noise Reject | |||
Trigger Sensitivity | DC(CH1,CH2): AC; HF Reject; LF Reject | |||
Trigger Level Range | CH1/CH2: ±8 divisions from center of screen; | |||
Video Trigger | ||||
Video Trigger Type | CH1, CH2: Peak-to-peak amplitude of 2 divisions; | |||
Signal Formats and Field Rates | Supports NTSC, PAL and SECAM broadcast systems for any field or any line | |||
Holdoff Range | 100ns ~ 10s | |||
Pulse Width Trigger | ||||
Pulse Width Trigger Mode | Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse | |||
Pulse Width Trigger Point | Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. | |||
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. | ||||
Less than: The trigger point is the trailing edge. | ||||
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width | ||||
Pulse Width Range | 20ns ~ 10s | |||
Slope Trigger | ||||
Slope Trigger Mode | Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope | |||
Slope Trigger Point | Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. | |||
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. | ||||
Less than: The oscilloscope triggers when the waveform slope is less than the set slope. | ||||
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. | ||||
Time Range | 20ns ~ 10s | |||
Overtime Trigger | ||||
Over Time Modee | Rising edge or Falling edge | |||
Time Range | 20ns ~ 10s | |||
Alternative Trigger | ||||
Trigger on CH1 | Internal Trigger: Edge, Pulse Width, Video, Slope | |||
Trigger on CH2 | Internal Trigger: Edge, Pulse Width, Video, Slope | |||
Trigger Frequency Counter | ||||
Readout Resolution | 6 digits | |||
Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) | |||
Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth | |||
Signal Source | Pulse Width or Edge Trigger modes: all available trigger sources | |||
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. | ||||
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. | ||||
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. | ||||
Video Trigger mode: The Frequency Counter does not work. | ||||
Measure | ||||
Cursor Measurement | Manual: Voltage difference between cursors: deltaV | |||
Time difference between cursors: deltaT | ||||
Reciprocal of deltaT in Hertz (1/deltaT); | ||||
Tracing: The valtage and time at a waveform point; | ||||
Auto Measuerment | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, | |||
Scope Trendplot | 1.2M Point | |||
General Specifications | ||||
Display Resolution | 640 horizontal by 480 vertical pixels | |||
Display Contrast | Adjustable (16 gears) with the progress bar | |||
Frequency(typical) | 1kHz | |||
Dimension | 260mmmm; 220mm; 75mm | |||
Weight | 2.5KG(without Packing) |