DSO1202E,2 channel handheld oscilloscope,200MHz Bandwidth

DSO1202E,2 channel handheld oscilloscope,200MHz Bandwidth

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
10000 Piece / Pieces per Month
Port:
xiamen shenzhen
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Model Number:
DSO1202E

Xiamen Wellzion Electronics Co., Ltd.

Business Type: Trading Company
Xiamen Fujian China
Main Products: Power Supply ,Oscilloscope ,Multimeter ,Spectrum Analyzer ,Temperature Test Instruments

Product Details

Specifications

DSO1202E,200MHz 2 channel handheld oscilloscope
1GS/s sample rate,6000 Counts DMM with analog bargraph
2M Memory Depth

 

Function & Benefits
  • Five in one: Oscilloscope/Recorder/DMM/FFT Spectrum Analyzer/Frequency Counter
  • 2000MHz Bandwidth, 1GS/s sample rate,6000 Counts DMM with analog bargraph
  • 5.6 inch TFT LCD Display,640*480; Dual-Window Design for more detailed
  • Easy-to-use pop-up menu with built-in multi-language help system
  • 2M Memory Depth and 32 Automatic Measurements
  • Automatic cursor tracking measurements
  • Average Mode for smoothing waveforms
  • USB Host/Device 2.0 full-speed interface; support removeable disk;LAN Option, easy to control by PC or long-distance
Specifications

 

ModelDSO1072EDSO1102EDSO1152EDSO1202E
Sample ModesReal-Time Sample
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs CouplingAC, DC, GND
Inputs Impendance1MΩ±2% ll20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×)
Horizontal System
Sample Rate Range1GS/s
Waveform Interpolation(sin x)/x
Record Length2M
SEC/DIV Range4ns/div~2000s/div, in a  2, 4, 8 sequence2ns/div~2000s/div, in a  2, 4, 8 sequence
Sample Rate and Delay Time Accuracy±50ppm over any ≥1ms time interval
Scanning Speed Range4ns/div to 8ns/div; (-8div x s/div) to 40ms;
20ns/div to 80μs/div;(-8div×s/div) to 40ms
200μs/div to 40s/div; (-8div×s/div) to 400s
2ns/div to10ns/div;
 (-4div×s/div) to 20ms;
Delta Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Volts Range2mV/div to 100V/div at input BNC
Bandwidth70MHz100MHz150MHz200MHz
Rise Time at BNC( typical)5ns3.5ns2.3ns1.8ns
Analog Bandwidth in Normal and Average
modes at BNC or with probe, DC Coupled
±400V(100V/div-20V/div);  ±50V(10V/div-5V/div); ±40V(2V/div-500mV/div); 
±2V(200mV/div-50mV/div); ±400mV(20mV/div-2mV/div)
Math+, -, *, /, FFT
FFTWindows:Hanning, Flatop, Rectamgular, Bartlett, Blackman; 1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
Trigger System
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, HF Reject, LF Reject, Noise Reject
Trigger SensitivityDC(CH1,CH2): AC; HF Reject; LF Reject
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen; 
Video Trigger
Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;
Signal Formats and Field RatesSupports NTSC, PAL and SECAM broadcast systems for any field or any line
Holdoff Range100ns ~ 10s
Pulse Width Trigger
Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulse
Pulse Width Trigger PointEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width
Pulse Width Range20ns ~ 10s
Slope Trigger
Slope Trigger ModeTrigger when (< , > , = , or ≠ ); Positive slope or Negative slope
Slope Trigger PointEqual: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range20ns ~ 10s
Overtime Trigger
Over Time ModeeRising edge or Falling edge
Time Range20ns ~ 10s
Alternative Trigger
Trigger on CH1Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger on CH2Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution6 digits
Accuracy (typical)±30ppm (including all frequency reference errors and ±1 count errors)
Frequency RangeAC coupled, from 4Hz minimum to rated bandwidth
Signal SourcePulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.
Measure
Cursor MeasurementManual: Voltage difference between cursors: deltaV
Time difference between cursors: deltaT
Reciprocal of deltaT in Hertz (1/deltaT);
Tracing: The valtage and time at a waveform point;
Auto MeasuermentFrequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS,
Scope Trendplot1.2M Point
General Specifications
Display Resolution640 horizontal by 480 vertical pixels
Display ContrastAdjustable (16 gears) with the progress bar
Frequency(typical)1kHz
Dimension260mm*220mm* 75mm
Weight2.5KG(without Packing)

Contact Supplier

Ms. Melissa Zhang Chat Now
Telephone
86-592-5562446
Fax
86-592-5562446
Address
ROOM 608,B BUILDING,SEG E-MART, NO.806 YUANSHAN NAN ROAD,XIAMEN,FUJIAN,CHINA Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Oscilloscopes
Categories
Hi~