Current and Voltage Calibrator,handheld calibrator,Volt Calibrator,0.05% Accuracy
Negotiable /Piece
Min.Order:1 Piece
Xiamen Wellzion Electronics Co., Ltd.
Current and Voltage Calibrator,Volt Calibrator,handheld calibrator,0.02% Accuracy
ETX-1812,RTD Calibrator,Handheld Calibrator,Calibrator RTD,0.05% Accuracy
ETX-2012,RTD Calibrator,Handheld Calibrator,Calibrator RTD,0.02% Accuracy
ETX-2012,RTD Calibrator,Handheld RTD Calibrator,Calibrator for RTD,0.02% Accuracy
ETX-1812,RTD Calibrator,Handheld RTD Calibrator,Calibrator for RTD,0.05% Accuracy
Current and Voltage Calibrator,Current Calibrator,Voltage Calibrator,0.02% Accuracy
Features and Benefits
Summary of Source and Measure Functions
Function | Measure | Source |
DC V | 0~30 V | 0~10 V |
DC mV | 0~100 mV | 0~100 mV |
DC mA | 0~24 mA | 0~24 mA |
Frequency | 1.000Hz~99.999kHz | 0.00Hz~20.000kHz |
Others | 24V power supply, Step, Ramp. |
Specifications
Specifications are based on a one year calibration cycle and apply from +18°Cto +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.
1,DC Voltage Measurement
Range | Maximum measurement range | Resolution | Accuracy (% of reading + Counts) | |
ETX-1815 | ETX-2015 | |||
30V | 0V~31V | 0.001V | 0.05+2 | 0.02+2 |
100mV | -15mV~125mV | 0.01mV | 0.05+2 | 0.02+2 |
-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C. Input resistance: >1MΩ. |
2,DC mA Measurement
Range | Maximum measurement range | Resolution | Accuracy (% of reading + Counts) | |
ETX-1815 | ETX-2015 | |||
20mA | 0~24mA | 0.001mA | 0.05+2 | 0.02+2 |
-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C. Input resistance:<100Ω. |
3,Frequency Measurement
Range | Maximum measurement range | Resolution | Accuracy (% of reading + Counts) | |
ETX-1815 | ETX-2015 | |||
100Hz | 1~99.999Hz | 0.001Hz | 0.02+1 | 0.01+1 |
1000Hz | 100~999.99Hz | 0.01Hz | ||
10kHz | 1k~9.9999kHz | 0.1Hz | ||
100kHz | 10k~99.999kHz | 1Hz | ||
Sensitivity: 10Hz~10kHz,Vp-p≥1V; the rest:Vp-p≥2V. Wave form: 5 counting points should be added to errors of other wave forms. Commercial frequency can be measured directly. |
Product Accessories
1,Standard Accessories
A set of ETX-2015/ETX-1815 calibrator also includes the following items:
2,Optional Accessories