ETX-1812,RTD Calibrator,Handheld Calibrator,Calibrator RTD,0.05% Accuracy

ETX-1812,RTD Calibrator,Handheld Calibrator,Calibrator RTD,0.05% Accuracy

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
500 Piece / Pieces per Month
Port:
xiamen
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Fujian, China
Model Number:
ETX-1812

Xiamen Wellzion Electronics Co., Ltd.

Business Type: Trading Company
Xiamen Fujian China
Main Products: Power Supply ,Oscilloscope ,Multimeter ,Spectrum Analyzer ,Temperature Test Instruments

Product Details

Specifications

It allows you to measure voltage, resistance, and RTD.
Manual stepping, automatic stepping, 0~100% phase step and ramp output.

Features and Benefits

Summary of Source and Measure Functions

Function

Measure

Source

DC V

0~30V

Not available

Resistance

0~3200Ω

0~3200Ω

RTD

Pt100, Pt1000, Cu50, Cu100

Pt100, Pt1000, Cu50, Cu100

Others

Stepping output, ramp, phase step output, user-defined range

Specifications

Specifications are based on a one year calibration cycle and apply from +18°Cto +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.

1,DC Voltage Measurement

Range

Maximum measurement range

Resolution

Accuracy (% of reading + Count)

ETX-1812

ETX-2012

30V

0V~31V

0.001V

0.05+2

0.02+2

-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.

Input resistance: >1MΩ.

2,Resistance Measurement

Range

Maximum measurement range

Resolution

Accuracy (Ω)

ETX-1812

ETX-2012

2-wire, 3-wire

4-wire

2-wire,

3-wire

4-wire

400Ω

0~440Ω

0.01Ω

0.25

0.15

0.15

0.10

3200Ω

420Ω~3600Ω

0.1Ω

1.5

1.0

1.0

0.5

-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.

Exciting current during measurement:

400Ω:1.0mA±10%;

3200Ω:0.2mA±10%;

Two-wire: Conductor resistance is excluded from errors.

Three-wire: Matching test line should be used. The total resistance of conductor should not be larger than 25Ω.

3,Resistance Output

Range

Maximum output range

Resolution

External exciting current

Accuracy (Ω)

ETX-1812

ETX-2012

400Ω

0~440Ω

0.01Ω

0.4mA~4.0mA

0.25

0.15

3200Ω

400~3600Ω

0.1Ω

0.1mA~0.5mA

1.0

0.50

-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C.

4,RTD

Graduation

Range

Resolution

Accuracy (°C)

ETX-1812

ETX-2012

2-wire

3-wire

4-wire

Output

2-wire

3-wire

4-wire

Output

Pt100

-200°C~850°C

0.1°C

0.7

0.4

0.7

0.4

0.3

0.3

Pt1000

-200°C~650°C

0.4

0.3

0.3

0.3

0.15

0.15

Cu50

-50°C~150°C

1.2

0.8

0.8

0.8

0.5

0.5

Cu100

-50°C~150°C

0.7

0.4

0.4

0.4

0.25

0.25

As for exciting current during measurement, please refer to resistance measurement function.

As for allowable external exciting current during output, please refer to resistance output function.

2-wire: Does not include lead resistance.

3-wire: Assumes matched leads with a total resistance not exceeding 25Ω.

Product Accessories

1,Standard Accessories

A set of ETX-2012/ETX-1812 calibrator also includes the following items:

hard spot test leads (one set)

alligator clips (one set)

One 12V/1A power adaptor

ETX-2012/ETX-1812 Users Manual

2,Optional Accessories

6 R03-model rechargeable batteries

1 Metal Box

Contact Supplier

Ms. Melissa Zhang Chat Now
Telephone
86-592-5562446
Fax
86-592-5562446
Address
ROOM 608,B BUILDING,SEG E-MART, NO.806 YUANSHAN NAN ROAD,XIAMEN,FUJIAN,CHINA Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Other Measuring & Analysing Instruments
Categories
Hi~