AE2300, 34/32 Dynamic Range Palm OTDR
Negotiable /Piece
Min.Order:1 Piece
Xiamen Wellzion Electronics Co., Ltd.
Victor 25,victor process calibrator,multifunction process calibrator
Victor 01,temperature calibration,meter calibration,0.05% accuracy calibrator
Victor 01,Temperature Calibrator,victor calibrator,0.05% accuracy
Victor 25,electric meter calibration,victor calibrator,0.02% accuracy
Victor 25,Process Calibrator,multifunction process calibrator,0.02% accuracy
AE2300, 34/32 Dynamic Range Palm OTDR
The AE2300 is a high performance, handheld OTDR, designed for installation and maintenance of fiber optics networks. This lightweight and rugged OTDR includes a VFL, enabling the user t o quickly find impairments and location of the faults.
Model | AE2300L | AE2300 | AE2300H |
Wave length | 1310/1550 | 1310/1550 | 1310/1550 |
Dynamic Range(dB) | 30/28 | 34/32 | 36/34 |
Event DZ (m) | 3 | 1.5 | 0.8 |
Attenuation DZ (m) | <15 | <8 | <5 |
Distance | 3m~160km | ||
Pulse Width | AE2300L/AE2300: 5ns~20μs, AE2300 3ns~20μs | ||
Measurement Time | User-defined | ||
Distance Uncertainty | ±(1m+0.0005%×Distance + Sampling Resolution) | ||
Loss Threshold | AE2300L/AE2300: 0.05dB, AE2300H 0.03dB | ||
Loss Resolution | 0.001dB | ||
Distance Resolution | 0.05m | ||
Linearity | 0.04dB/dB | ||
Sampling Points | 128000 | ||
Display | 4.3 inch 16:9 TFT Touch Screen | ||
Data Storage | >4000 | ||
Optical Adapter | FC/PC, SC/PC | ||
Interface | USB, RJ45 | ||
Battery | Lithium Battery; Charging <4 hours, Operating time >8 hours | ||
Weight | <1kg |
Interface (RJ45, USB)
RJ45: Remote control and data sharing
USB : For transferring stored results
Optical Adapter: Easy to replace and clean
Visual Fault Locator(VFL): High power visual fault locator could be used to locate fiber problems quickly.
Auto Diagnosis and Auto Correction
Optical adapter detection and protection:
AE2300 triggers an alarm when light injection has been found at the optical adapter detects light.
Optical adapter connection detection
Warning is provided if optical adapter is damaged in order to avoid influencing the test result.
Self calibration and correction: Auto calibration function could self-calibrate the instrument.
Model AE2300L AE2300 AE2300H
Wave length 1310/1550 1310/1550 1310/1550
Dynamic Range(dB) 30/28 34/32 36/34
Event DZ (m) 3 1.5 0.8
Attenuation DZ (m) <15 <8 <5
Distance 3m~160km
Pulse Width AE2300L/AE2300: 5ns~20μs, AE2300 3ns~20μs
Measurement Time User-defined
Distance Uncertainty ±(1m+0.0005%×Distance + Sampling Resolution)
Loss Threshold AE2300L/AE2300: 0.05dB, AE2300H 0.03dB
Loss Resolution 0.001dB
Distance Resolution 0.05m
Linearity 0.04dB/dB
Sampling Points 128000
Display 4.3 inch 16:9 TFT Touch Screen
Data Storage >4000
Optical Adapter FC/PC, SC/PC
Interface USB, RJ45
Battery Lithium Battery; Charging <4 hours, Operating time >8 hours