vacuum controller
Negotiable /Unit
Min.Order:1 Unit
AMBETRONICS ENGINEERS PRIVATE LIMITED
Vacuum Controller
FEATURES:
APPLICATIONS:
TECHNICAL SPECIFICATIONS | |||
Input | 2 NO x Pressure & Vacuum in Kg/cm2, mBAR, BAR / Kg, mm Hg, mmH2O, PSI ; as per customer requirement | ||
Range | As per the Range selected by User | ||
Resolution | 0.001, 0.01, 0.1, 1; Programmable by User | ||
Accuracy | ± 0.25% of Full Scale | ||
Display | Upper (CH - 1) : 4 Digit, 0.56" (13 mm), 7 segment GREEN L.E.D. display | ||
L.E.D. Indication | L.E.D. Indication TD1 & TD2 for Time Delay, RL1 & RL2 for Relay, TX & RX for Communication, PRG to show 'User' in programming Mode | ||
Set point | 2 No Independent set points, one each for RL1 & RL2 with programmable Latch & Non-Latch facility | ||
Hysteresis | 0 To 10, Individual setting for RL1 & RL2 | ||
Control action | LO - HI, HI -LO, LO -Very LO, HI - Very HI; Programmable by user | ||
Time delay | 0 To 9999Sec, Independent setting for RL1 & RL2 to operate after the 'Process Value' crosses the 'Set point Value' | ||
Relay contact type | 1 NO/C/NC Relay contact rated 230 VAC / 5A For RL1 & RL2 | ||
Configuration of relay | RL1 operates for CH-1, RL-2 operates for CH-2 | ||
Fault condition | In 'Under', 'Over' OR 'Open' condition i.e. fault condition, Relay can be made OFF or ON; Programmable by user | ||
Setting | Setting by 4 keys on front panel i.e. 'SET / NEXT', 'UP', 'DOWN' & 'BACK' | ||
Monitoring | 1)By Display : Sensor 'Break/Open' shows 'oPEn', 'Under' range shows 'Undr' & 'Over' range shows 'ouEr' | ||
Retransmission output | i) No of Current outputs : 2 No, 4 - 20 mA or 20 - 4 mA programmable with MAX load 750 ohms for CH-1 & CH-2 | ||
Communication | Modbus RTU protocol with Isolated RS – 485 Communication | ||
Supply Voltage | 230 VAC ± 10% OR 110 VAC ± 10% OR 24 VDC | ||
Operating Temperature | - 40 To 85oC | ||
Relative humidity | Below 95% non condensing | ||
Enclosure Detail | PANEL MOUNTING(PM) | WEATHERPROOF (WP) | FLAMEPROOF (FLP) |
Protection Class | IP - 40 | IP-65 | IP – 65 CMRI Approved for Gas Gr. IIA & IIB |
Cabinet Material | ABS Plastic, Black / White Colour | Polycarbonate, Grey colour | Cast Al. alloy, LM-6 / C.I. Enclosure |
Cable Entry | Terminal connectorfor connection | Thermoplastic cable gland (IP - 68) | Double compression cable gland (Ex-Proof)¾" ET-type |
Dimension | 96 (H) X 96 (W) X 120 (D) in mm | 255 (H) X 240 (W) X 120 (D) in mm | 300 (H) X 250 (W) X 110 (D) |
Mounting | Panel mounting | Wall Mounting / Stand Mounting | Wall Mounting / Stand Mounting |
Weight | Approx. 1.0 Kg | Approx. 2.5 Kg | Approx. 4.0 Kg |