People Counting System / Traffic counter for Buses
USD $1 - $350 /Unit
Min.Order:1 Unit
Xiamen Xinsenyue Technology Co., Ltd.
People Counting System / Traffic counter for Buses :
XINSENYUE- GKM bus passenger counting system includes senor, processor, Memory moudle. This device is installed for monitor people in the bus. It should be installed according to the size of bus door,in general, width 1.2 meter's door, there are one processor,3 sensors in each door.
Sensors are responsible for catching information of passenger passing and sending to processor.Door s
witch is for inspecting the state of bus doors,door switch is mounted on the door frame to check the state of door,start or close
detecting function of processor.when the magnetic departs from door switch,door opens,the indicator goes off,at this time,
processor starts counting function.otherwise,the indicator flashes.Processors are for receiving information from tranducers and counting.
The counter system is also can be connect to GPRS device, such as GPS. the passenger data can be transfer to the servcer, then you can check monitor the bus in the office at any time.
Main specification
Communication baud rate:9600bps
Max mounting distance between emitter and counter: 3m
Anti-vibration ability: amplitude 0.35mm, 60-200Hz; ACC 50m/s2
Temperature range: -20 ~ +65℃
Working voltage: -20 ~ +65℃; voltage fluctuation: 15%
Detectable max traffic speed : 6m/s
Mounting of Pedestrian Flow Transducer
As default settings of mounting height was made before leaving factory, the operator shallhat it can be mounted properly for the height of the bus door(Normally, the height of bus door is 2.0m). The allowed variation for the mounting height is 10cm beyond which it may lead to unusual problems for the operation of the transducer. Please specify upon ordering if a special mounting height is used.
The mounting height herein refers to the vertical distance between the mounting location of the pedestrian flow
transducer and the lowest flow by the bus door and would changes as the mounting location changes. T
herefore, prior to purchasing a pedestrian flow transducer, please verify the best mounting location
and calculate the according mounting height so as to avoid any unusual operative problems.
In case that users find out the practical mounting location is varied from the settled mounting location over15 cm,
please contact us immediately.
Transducer mounting place
Transducer is mounted directly above the effective passage area of the bus. it couldn’t impact or affect the bus
top mechanism when the door is open.
Available passing area | Number of sensor |
Within 70cm | 1 |
75cm -- 90cm | 2 |
Over 95cm | 3 |
Connect to GPS
The counter system can be connect to GPRS device, such as GPS, the passenger data and GPS info can be transfer to the server.
Packaging&Shipping
MOQ | 1 set |
Lead time | Within 1 week for the sample, 15 days for bulk order |
Delivery Clause | FOB XIAMEN |
Terms of payment | T/T, L/C, Western Union |
Supply Ability | 5000 sets / month |
1)30% advance TT, the balance is paid against the copy of BL
2)100% irrecovable LC at sight
Company Information
Xiamen Xinsenyue Mechanical & Electrical Co.,Ltd. is the manufacturer of "sop arm","automatic passenger counter & GPS system","automatic bus LCD monitor","Car gas leak alarm system","Bus Patrol System"…,
* We are the manufacturer,
* Would provide good quality product,
* Can save your money,
* Can provide better service,
* CEM or ODM is OK.