Intelligence two door bus people counter passenger infrared counters

Intelligence two door bus people counter passenger infrared counters

USD $80 - $600 /Set

Min.Order:1 Set

Supply Ability:
10000 Set / Sets per Month
Port:
XIAMEN
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

Place of Origin:
Fujian, China
Brand Name:
XINSENYUE
Model Number:
XSY-GKM

Xiamen Xinsenyue Technology Co., Ltd.

Business Type: Manufacturer,Trading Company
Xiamen Fujian China
Main Products: Stop Arm ,Auto Fire extinguisher ,Auto Parts ,Automatic people counter system ,DVR

Product Details

Intelligence two door bus people counter : 

XINSENYUE- GKM bus passenger counting system includes senor, processor, Memory moudle. This device is installed for monitor people in the bus. It should be installed according to the size of bus door,in general, width 1.2 meter's door, there are one processor,3 sensors in each door. 

Sensors are responsible for catching information of passenger passing and sending to processor.Door s

witch is for inspecting the state of bus doors,door switch is mounted on the door frame to check the state of door,start or close

 detecting function of processor.when the magnetic departs from door switch,door opens,the indicator goes off,at this time,

processor starts counting function.otherwise,the indicator flashes.Processors are for receiving information from tranducers and counting.

 

The counter system is also can be connect to GPRS device,  such as GPS. the passenger data can be transfer to the servcer, then you can check monitor the bus in the office at any time.

Intelligence two door bus people counter passenger infrared counters

Intelligence two door bus people counter passenger infrared counters

 

Main specification
Communication baud rate:9600bps
Max mounting distance between emitter and counter: 3m
Anti-vibration ability: amplitude 0.35mm, 60-200Hz; ACC 50m/s2
Temperature range: -20 ~ +65℃

voltage fluctuation: 15%
Detectable max traffic speed : 6m/s

Mounting of Pedestrian Flow Transducer
As default settings of mounting height was made before leaving factory, the operator shallhat it can be mounted properly for the height of the bus door(Normally, the height of bus door is 2.0m). The allowed variation for the mounting height is 10cm beyond which it may lead to unusual problems for the operation of the transducer. Please specify upon ordering if a special mounting height is used.

Intelligence two door bus people counter passenger infrared counters

The mounting height herein refers to the vertical distance between the mounting location of the pedestrian flow transducer and the lowest flow by the bus door and would changes as the mounting location changes. T

herefore, prior to purchasing a pedestrian flow transducer, please verify the best mounting location 

and calculate the according mounting height so as to avoid any unusual operative problems.
In case that users find out the practical mounting location is varied from the settled mounting location over15 cm, 
please contact us immediately.

 
Transducer mounting place
 
Transducer is mounted directly above the effective passage area of the bus. it couldn’t  impact or affect the bus 
top mechanism when the door is open. 

Intelligence two door bus people counter passenger infrared counters

 

In order to get a no blind zone for monitoring, it is important to select suitable numbers of transducers to mount above the door according to the available passing areas of the bus door.

 

 

 

Available passing areaNumber of sensor
Within 70cm1
75cm -- 90cm2
Over 95cm3

 

When totally three transducers have to be mounted, the middle one shall be located right on the cut line 
between the two door, keeping 17cm from either if the other two transducers.From left to right, they are t
ransducer 1#, transducer 2#, transducer 3#. All three transducers must be in the same section.
Intelligence two door bus people counter passenger infrared counters
Connection Instruction
Intelligence two door bus people counter passenger infrared counters
Gate control switcher
Gate controlled switch must be applied with magnetic mass by which the magnetic switch is on with magnetic
 field around it. If there are no magnetic field around the switch or the intensity of magnetic field is less than 
the required level, the switch is off.
 
Intelligence two door bus people counter passenger infrared counters
Gate controlled switch shall be installed near the rotating column of the bus door or above the door leaf, 
so the intensity of the magnetic field would fluctuate according to the distance variation, producing signal 0 
or signal 1. Thus,the switch can detect if the bus door is open or close.
 
Processor
 
One set of the contains two pedestrian flow processing units . The one with ID 0001shall be installed
 in the darkroom on the top of the front bus door; the one with ID 0002 shall be installed in the darkroom 
on the top of the rear bus door. The two processing units are used to calculate the pedestrian flow at the front and the rear bus door, respectively.
The pedestrian flow processing unit is connected with the pedestrian flow transducer mounted above the bus 
door and applied to process the detective signals of the pedestrian flow transducer and calculate the flow 
at certain bus door. Five indicators on the panel of the processing unit show the current status.
Intelligence two door bus people counter passenger infrared counters
SD Memory Module
The SD memory module could record the pedestrian flow at the front and rear bus doors during every times 
opening and closing as well as accordingly time wasted on closing the door. The file is named with date and 
stored in SD memory card. Data of the SD card can be transferred into computer by using SD readers and 
used in statistic with management software of pedestrian flow.The LCD monitor on the panel could display 
informations like current system date. If there's deviation, please manually adjust.
Intelligence two door bus people counter passenger infrared counters
Intelligence two door bus people counter passenger infrared counters

Connect to GPS

 

The counter system can be connect to GPRS device, such as GPS, the passenger data and GPS info can be transfer to the server.

Intelligence two door bus people counter passenger infrared countersIntelligence two door bus people counter passenger infrared counters

Packaging&Shipping

MOQ1 set
Lead timeWithin 1 week for the sample, 15 days for bulk order
Delivery ClauseFOB XIAMEN
Terms of paymentT/T, L/C, Western Union
Supply Ability5000 sets / month

 

1)30% advance TT, the balance is paid against the copy of BL

2)100% irrecovable LC at sight

Company Information

 

The Information of XINSENYUE

    XIAMEN XINSENYUE TECHNOLOGY CO,.LTD was founded in 2007 , located at Xiamen of Fujian province, specialized design production school bus stop arm in electric, GKM tracking system, passenger counters system, automatic fire extinguisher and other safety products. XINSENYUE engaged in design and production, sales, after service. We have rich information for exploring quickly development market, we have always placed people first, had high level of specialization, of good quality, and morals first. We will endeavor to build and develop “XINSENYUE plot” enterprise culture. We promoted enterprise’s quality and core competence, pursued anew development.

Contact Supplier

Mr. kevin Q Manager Chat Now
Telephone
86-592-2033185
Mobile
15980823521
Fax
86-592-6533536
Address
Haicang district, Xinyang street Xiamen,Fujian

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Counters
Categories
Hi~