Technical Parameters
Technical Parameters | |
Operating Voltage | 9V 6F22 battery |
Working current | ≤ 30 mA |
Static current | ≤ 15uA |
Emission Distance | open distance≥100m |
Installation Way | Wall hanging |
Installation Height | 2.2m |
Detection Degree | 110°( curtain15°) |
Detection Range | 12m ( curtain 8m) |
Coding Method | 2262/5211IC |
Emission frequency | 315MHz/433MHz |
Dimensions | 110×60×42MM |
Use Instructions
1. Function Setting
1. LED indicator light choice(J1): The choice of 1&2(ON) means to turn on the indicator light, when detector is triggered, the indicator will light. To choose 2&3(OFF) means to turn off the indicator, even detector is triggered, would not light.
2.Delayed adjustment (DELAY): Choice with 1&2 (2min) means the alarm would occur in 2 minutes after the trigger, that is, till 2min late, another trigger would be effective; Choice with 2&3 (4min) means the delayed alarm would be effective in 4 min after the trigger, this mode is for power saving.
3.Sensitivity adjustment (P.COUNT): choice with 1&2(1P) is for high sensitivity which is suitable to normal environment; 2&3(2P) is for low sensitivity, suitable to severe interference environment.
4.Working Mode Choice(TEST/USE): Choice with 1&2 (USE) is for power saving mode; Choice with 2&3 (TEST) is for USE mode.
5. Oscillation resistance adjustment(J3 ) skipping is used to set the oscillation resistance to be 1.5M/3.3M/4.7M. You can choose oscillation resistance to connect relevant skipping.
6.Coding skipping(J6): It is used for setting the address code and defense code between detector and alarm host, A0~A7 is address code, the code corresponds to alarm host. D0~D3 is data code, it is used to set alarm defense zone.
7. Undervoltage indication: When voltage is lower than set point, LED light keeps flashing indicating battery voltage is low, need exchanging with a new battery.
2. Product testing
Turing power switch to “ON”, the LED indicator light flashes for 2 seconds, enter into self-checking condition, self-checking time is about 30 seconds, after 30s, it get into normal monitoring condition. When testing, please set the working mode to be (TEST), then walk back and forth within detection range, the LED indicator light would be on, indicate that detector gets into alarm condition.
Installation Instructions 1. Choosing installation position according to actual condition (height 2.2m suggeste
2. Should avoid installing where’s near air-conditioner, heat source, outdoors, pets and sun exposure.
3. Try to install where the illegal intruders mostly burst into.
4. Try to avoid installing at the exits of cold or hot air.
5. Avoid protective zone to be fade area.
6. Fixing detector bracket into wall by screw, then clip the detector into bracket.
7. Adjusting detection degree according to actual condition.
Notices
1. The detection distance of PIR detector is affected by outside temperature.
2. Burglarproof product can strengthen security coefficient, but it cannot guarantee 100% safety, we should heighten safety consciousness to avoid lost.
3. After debugging detector successfully, in order to strengthen the elusive capacity, suggest disconnecting LED jumper, and make LED indicator light be off.
4. When voltage is lower than set point, the indicator light keeps flashing and emits alarm signal towards the outside, warning the host to exchange battery to keep working normally.