XLPE Cable,ABC Power Cable/Alumnium bundled Power Cable
Negotiable /Meter
Min.Order:1000 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
XLPE Cable,ABC Power Cable/Alumnium bundled Power Cable
1.Standards
-The Aerial Insulated Cable meets the China National standard of GB/T14049-2008
-Also accept OEM and custom request .
2.Applications
-Copper Conductor or Aluminum Conductor with XLPE or HDPE insulation Aerial Cable is suiltable for aerial power lines with A.C. rated voltage U/Um upto 10/12kv and 35/42kv
-The soft copper conductor cable is used as lead of transformer. A certain distance should be kept between cable and trees while installation.
5. Properties
-Rated Volatge Uo/U is 0.6/1kV.
-ntinuous operating temperature
For PE and PVC not exceed 70°C
For XLPE not exceed 90 °C
-Cable installation ambient temperature: no less than -20°C
-Min. bending radius.
For diameter less than 25mm, shall be 4 times cable outer diameter.
For diameter equel to or more than 25, shall be 6 times cable outer diameter
Copper Wire Core | |||||
Cross-Section Area (mm²) | Max.Overall Diameter (mm) | Max.D.C. Resistance at 20 °C (Ω/km) | Min. Insulation Resistance at 90°C (MΩ/km) | Breaking Load of cable (N) | Weight of cable (kg/km) |
10 | 6.5 | 1.906 | 0.67 | 3471 | 106 |
16 | 8 | 1.198 | 0.65 | 5486 | 168 |
25 | 9.4 | 0.749 | 0.54 | 8465 | 254 |
35 | 11 | 0.54 | 0.54 | 11731 | 354 |
50 | 12.3 | 0.339 | 0.46 | 16502 | 496 |
70 | 14.1 | 0.276 | 0.4 | 23461 | 683 |
95 | 16.5 | 0.199 | 0.39 | 31759 | 925 |
120 | 18.1 | 0.158 | 0.35 | 39911 | 1157 |
150 | 20.2 | 0.128 | 0.35 | 49505 | 1448 |
185 | 22.5 | 0.1021 | 0.35 | 61846 | 1786 |
240 | 25.6 | 0.0777 | 0.34 | 79823 | 2310 |
Aluminum Wire Core | |||||
Cross-Section Area (mm²) | Max.Overall Diameter (mm) | Max.D.C. Resistance at 20 °C (Ω/km) | Min. Insulation Resistance at 90°C (MΩ/km) | Breaking Load of cable (N) | Weight of cable (kg/km) |
10 | 6.5 | 3.08 | 0.67 | 1650 | 43 |
16 | 8 | 1.91 | 0.65 | 2517 | 68 |
25 | 9.4 | 1.2 | 0.54 | 3762 | 97 |
35 | 11 | 0.868 | 0.54 | 5177 | 135 |
50 | 12.3 | 0.641 | 0.46 | 7011 | 182 |
70 | 14.1 | 0.443 | 0.4 | 10354 | 244 |
95 | 16.5 | 0.32 | 0.39 | 13727 | 330 |
120 | 18.1 | 0.253 | 0.35 | 17339 | 406 |
150 | 20.2 | 0.206 | 0.35 | 21033 | 508 |
185 | 22.5 | 0.164 | 0.35 | 26732 | 626 |
240 | 25.6 | 0.125 | 0.34 | 34679 | 806 |
Al Alloy core | |||||
Cross-Section Area (mm²) | Max.Overall Diameter (mm) | Max.D.C. Resistance at 20 °C (Ω/km) | Min. Insulation Resistance at 90°C (MΩ/km) | Breaking Load of cable (N) | |
10 | 6.5 | 3.574 | 0.67 | 1650 | |
16 | 8 | 2.217 | 0.65 | 2517 | |
25 | 9.4 | 1.393 | 0.54 | 3762 | |
35 | 11 | 1.007 | 0.54 | 5177 | |
50 | 12.3 | 0.744 | 0.46 | 7011 | |
70 | 14.1 | 0.514 | 0.4 | 10354 | |
95 | 16.5 | 0.371 | 0.39 | 13727 | |
120 | 18.1 | 0.294 | 0.35 | 17339 | |
150 | 20.2 | 0.239 | 0.35 | 21033 | |
185 | 22.5 | 0.19 | 0.35 | 26732 | |
240 | 25.6 | 0.125 | 0.34 | 34679 |