pvc insulated single core copper cable/armed cable/new baofeng cable/copper cable/high voltage cables
USD $1 - $500 /Meter
Min.Order:500 Meters
Hebei New Baofeng Wire & Cable Co., Ltd.
Cu/Al Conductor PVC/XLPE Insulated PVC Sheathed 4 Core Power Cable
Model No : VV VLV VY VLY
Voltage : Low and Medium Voltage Cable
Conductor Material : copper
Insulation Material: XLPE
Sheath : PVC or PE
Appliation : Underground
Certificate : CE UL SGS ISO
Export Markets : Global
2.Construction :
1)The allowed long time working temperature of conducting core should not exceed 70 °C
2)When short-circuit (Max 5s), the highest working temperature of cable conductor should not exceed 165°C
3)While laying the cable, the ambient temperature should not be lower than 0°C
the bending radius should not less than 10 times of outer diameter of cable.
4)With good chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardant.
5)With light weight, perfect bending properties, stalled and maintained easily and conveniently
3. Specification :
Type |
Designation |
Application |
YJV |
Copper conductor, XLPE insulated and PVC sheathed power cable. | .. For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces, Single core cable in magnetic duct is not permissible. |
YJLV |
Aluminum conductor, XLPE insulated and PVC sheathed power cable. | |
YJY |
Copper conductor, XLPE insulated and PE sheathed power cable. | |
YJLY |
Aluminum conductor, XLPE insulated and PE sheathed power cable. | |
YJV22 |
Copper conductor, XLPE insulated, steel tape armored and PVC sheathed power cable. | ,,,. For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force. |
YJLV22 |
Aluminum conductor, XLPE insulated, steel tape armored and PVC sheathed power cable. | |
YJV23 |
Copper conductor, XLPE insulated, steel tape armored and PE sheathed power cable. | ,,,. For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force |
YJLV23 |
Aluminum conductor, XLPE insulated, steel tape armored and PE sheathed power cable. | |
YJV32 |
Copper conductor, XLPE insulated, steel wire armored and PVC sheathed power cable. | ,,. For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force. |
YJLV32 |
Aluminum conductor, XLPE insulated, steel wire armored and PVC sheathed power cable. | |
YJV33 |
Copper conductor, XLPE insulated, steel wire armored and PE sheathed power cable. | |
YJLV33 |
Aluminum conductor, XLPE insulated, steel wire armored and PE sheathed power cable. |
Type |
Number of cores | Rated Voltage KV | ||||||
3.6/6 | 6/6 6/10 | 8.7/10 8.7/15 | 12/20 | 18/20 18/30 | 21/35 | 26/35 | ||
Nominal cross-section area of conductor mm2 | ||||||||
YJV YJLV YJY YJLY | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | |
YJV22 YJLV22 YJV23 YJLV23 | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-500 | 35-500 | 50-400 | 50-400 | 50-400 | |
YJV32 YJLV32 YJV33 YJLV33 | 1 | 25-800 | 25-800 | 25-800 | 35-800 | 50-630 | 50-630 | 50-630 |
3 | 25-630 | 25-630 | 25-400 | 35-400 | 50-240 | 50-185 | 50-150 |
Reference Picures: