Meanwell 30v 20a switching power supply 600w high efficiency switched power supply
USD $1 - $100 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
meanwell 540w 15v 36a power supply high efficiency switcing power supply
Mean Well Single Output power supply with ups function AD-155A 155w battery charger ups power supply
Mean Well AD-55A 55w 13.8v switching power supply with battery charger UPS Function
Mean Well 155w battery charger 155W Battery Charger UPS Function
Original MEAN WELL
HEP-600-30
Output: 30V 20A 600W
Input: 90 ~ 305VAC 127 ~ 431VDC
Warranty: 6 years
Certificates: UL,CB,CE,EMC,TUV
MODEL | HEP-600-30 | |
OUTPUT | DC VOLTAGE | 30V |
RATED CURRENT | 20A | |
CURRENT RANGE | 0 ~ 20A | |
RATED POWER | 600W | |
RIPPLE & NOISE (max.) Note.2 | 200mVp-p | |
VOLTAGE ADJ. RANGE | 25.5 ~ 31.5V | |
CURRENT ADJ. RANGE | Can be adjusted by internal potentiometer | |
10 ~ 20A | ||
VOLTAGE TOLERANCE Note.3 | ±1.0% | |
LINE REGULATION | ±0.5% | |
LOAD REGULATION | ±0.5% | |
SETUP, RISE TIME Note.5 | 500ms, 80ms at full load 230VAC /115VAC | |
HOLD UP TIME (Typ.) | 15ms at full load 230VAC /115VAC | |
INPUT | VOLTAGE RANGE Note.4 | 90 ~ 305VAC 127 ~ 431VDC |
FREQUENCY RANGE | 47~63HZ | |
POWER FACTOR (Typ.) | PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load | |
EFFICIENCY (Typ.) | 95.5% | |
AC CURRENT (Typ.) | 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC | |
INRUSH CURRENT (Typ.) | COLD START 70A(t =1000 s measured at 50% I ) at 230VAC | |
LEAKAGE CURRENT | <0.75mA / 277VAC | |
PROTECTION | OVER CURRENT | 105 ~ 125% |
Protection type : Constant current limiting, recovers automatically after fault condition is removed | ||
SHORT CIRCUIT | Constant current limiting, recovers automatically after fault condition is removed | |
OVER VOLTAGE | 32.5 ~ 36.5V | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
OVER TEMPERATURE | Shut down o/p voltage, re-power on to recover | |
FUNCTION | 5V STANDBY | 5VSB : 5V at 0.5A ; tolerance ± 5%, ripple : 100mVp-p(max.) |
REMOTE ON/OFF CONTROL | Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit | |
ENVIRONMENT | WORKING TEMP. | -40~+70℃ (Refer to derating curve) |
WORKING HUMIDITY | 20~95% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40~+85℃, 10~95%RH | |
TEMP. COEFFICIENT | ±0.03%/℃(0~ 60℃) | |
VIBRATION | 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes | |
SAFETY&EMC (Note 6.) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH | |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level, criteria A | |
OTHERS | MTBF | 76.9K hrs min. MIL-HDBK-217F (25℃ ) |
DIMENSION | 280*144*48.5mm (L*W*H) | |
PACKING | 3.9Kg; 4pcs/16.6Kg/0.9CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltages. Please check the derating curve for more details. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. The power supply is considered as a component that will be operated in cpmbination with final equipment.Since EMC performance will be affected by the complete installation,the final equipment manufactures must re-qualify EMC Directive on the complete installation again. 7. The ambient temperature derating of 5℃/1000m is needed for operating altitude greater than 2000m(6500ft). 8.Refer to warranty statement. |