Meanwell 100w switching power supply with battery charger/100W Single Output with Battery Charger(UPS Function)
USD $1 - $100 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
Meanwell switching power supply 160w with battery charger/UPS Function power supply
Meanwell PCB type PSC-160B 160w with battery charger/UPS Function power supply
Meanwell led power supply 160w with battery charger PSC-160A-C enclosed type UPS power supply
Meanwell enclosed type PSC-160B-C 160w with battery charger/UPS power supply
MODEL | PSC-100B | ||
OUTPUT | OUTPUT NUMBER | CH1 | CH2
|
DC VOLTAGE | 27.6V | 27.6V
| |
RATED CURRENT | 2.4A | 1.25A
| |
CURRENT RANGE | 0~ 3.5A | -----
| |
RATED POWER | 100.74W | ||
RIPPLE & NOISE (max.) Note.1 | 100mVp-p | -------
| |
VOLTAGE ADJ. RANGE | CH1: 24~ 29V | ||
VOLTAGE TOLERANCE | ±1.0% | -----
| |
LINE REGULATION | ±0.5% | -----
| |
LOAD REGULATION | ±0.5% | ------
| |
SETUP,RISE TIME | 2400ms,30ms/230VAC 2400ms, 30ms/115VAC at full load | ||
HOLD UP TIME | 40ms / 230VAC 16ms/115VAC at full load | ||
INPUT | VOLTAGE RANGE | 90~264VAC 127~370VDC | |
FREQUENCY RANGE | 47 ~ 63Hz | ||
EFFICIENCY (Typ.) | 88% | ||
AC CURRENT (Typ.) | 2A/115VAC 1.2A/230VAC | ||
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | ||
LEAKAGE CURRENT | <1mA / 240VAC | ||
PROTECTION | OVER LOAD | Protection type : Hiccup mode, recovers automatically after fault condition is removed | |
105 ~ 150% rated output power | |||
OVER VOLTAGE | CH1:28.98 ~ 37.26V | ||
Protection type : Shut down o/p voltage, re-power on to recover | |||
BATTERY CUT OFF | 20± 1V | ||
ALARM FUNCTION | AC OK | Relay contact output, ON : AC OK ; OFF : AC Fail ; Max. rating : 30V / 1A | |
BATTERY LOW | Battery low voltage : < 11V | ||
Relay contact output, OFF : Battery OK ; ON : Battery Low ; Max. rating : 30V / 1A | |||
ENVIRONMENT | WORKING TEMP. | -20~+70°C (Refer to derating curve) | |
WORKING HUMIDITY | 20~90% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -20~+85°C, 10~95%RH | ||
TEMP. COEFFICIENT | ±0.03%/°C (0~50°C)on CH1 output | ||
VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes | ||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||
EMC EMISSION | Compliance to , EN55022 (CISPR22) Class B ; EN61000-3-2.3 | ||
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11,EN55024, light industry level, criteria A | ||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH | ||
OTHERS | MTBF | 417.6Khrs min. MIL-HDBK-217F (25°C) | |
DIMENSION | PCB:127*76.2*31mm (L*W*H) ; with optional CASE:130*85*37mm (L*W*H) | ||
PACKING | PCB:0.23Kg;63pcs/15.5Kg/1.35CUFT with optional CASE:0.44Kg;32pcs/15Kg/0.64CUFT | ||
NOTE | 1.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2.. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4The power supply is considered a component which will be installed into a final equipment. the final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies. 6 5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 6. 6.Heat sink HS1,HS2 can not be shorted. 7. 7.Heat sink HS1 must have safety isolation distance with system case. |