Meanwell 1500W True Sine Wave DC-AC Inverter with Solar Charger 24v inverter/solar off grid inverter/ac drive inverter
USD $340 - $405 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
Meanwell 3000W 48v True Sine Wave DC-AC Power Inverter/3kw low frequency inverter/dc/ac inverter
Meanwell 1500W True Sine Wave DC-AC Power inverter ac/inverter for home use/dc to ac inverter sale
Meanwell 1500W True Sine Wave DC-AC Power Inverter/inverter charger pure sine/wind inverters
Meanwell 1500W True Sine Wave DC-AC Power Inverter 24v inverter/dc to ac inverter design circuit
Mean well TS-1500-112 1500W True Sine Wave Inverter 1500w inverter
Meanwell 700W True Sine Wave DC-AC Power inverter ac inverters for home use ac drive inverter
MODEL | TN-1500-124 | |
OUTPUT | RATED POWER (Typ.) | 1500W |
MAXIMUM OUTPUT POWER(Typ.) | 1725W for 180 sec. / 1875W for 10 sec. / surge power 3000W for 30 cycles | |
AC VOLTAGE | Factory setting set at 110VAC | |
100 / 110 / 115 / 120VAC selectable by setting buttonS.W | ||
FREQUENCY | 60 ±0.1Hz 50/60Hz selectable by setting buttonS.W | |
WAVEFORM Note.2 | True sine wave (THD<3%) at rated input voltage | |
AC REGULATION (Typ.) | ±3.0% | |
TRANSFER TIME (Typ.) | 10ms inverter→ by pass | |
SAVING MODE (Typ.) | Default disabled. Load≤5W will be changed to standby mode | |
FRONT PANEL INDICATOR | Battery voltage level, output load level, saving mode, fault and operation status | |
INPUT
| BAT. VOLTAGE | 24V |
VOLTAGE RANGE (Typ.) Note. 3, 6 | 21~ 30VDC | |
DC CURRENT (Typ.) Note.5 | 75A | |
NO LOAD DISSIPATION | ≤18W at standby saving mode | |
OFF MODE CURRENT DRAW(Typ.) | ≤1mA | |
EFFICIENCY (Typ.) Note.2 | 89% | |
BATTERY TYPES | Open & sealed Lead Acid | |
BATTERY INPUT PROTECTION | FUSE | 30A*3 |
BAT. LOW ALARM | 22.5V±4% | |
BAT. LOW SHUTDOWN | 21V±4% | |
REVERSE POLARITY | By internal fuse open | |
OUTPUTPROTECTION | OVER TEMPERATURE | 82°C ± 5°C |
Protection type : Shut down o/p voltage, re-power on to recover ; by internal RTH3 detect on heatsink of power transistor | ||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 125% load for 10 sec. | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
CIRCUIT BREAKER | 20A | |
GFCI PROCTECTION | Optional (Only type F) | |
ENVIRONMENT | WORKING TEMP. Note.1 | 0~+40°C at 100% load 60°C at 50% load |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -30~+70°C / -22~ +158 F, 10~95%RH | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | UL458 (only for "GFCI" receptacle-Type F ) |
LVD | None | |
WITHSTAND VOLTAGE | Bat I/P - AC I/P:3.0KVAC Bat I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |
| EMC EMISSION | Compliance to FCC class A |
EMC IMMUNITY | None | |
AC CHARGER | CHARGE CURRENT (Typ.) | 2.7A |
CHARGE VOLTAGE | 28.5V±4% | |
SOLAR CHARGER | MAX OPEN CIRCUIT VOLTAGE | 45V |
CHARGE CURRENT (max.) | 30A | |
CHARGE VOLTAGE | 28.5V±4% | |
OTHERS | CONTROL WIRING | RJ11 -RS232 (Option) |
DIMENSION | 420*220*88mm (L*W*H) | |
PACKING | 6.85Kg; 2pcs/15.7Kg/1.61CUFT | |
NOTE | 1. Output derating capacity referenced by curve 1. 2. THD and Efficiency is tested by 1000W, linear load at 13V, 26V, 52V input voltage. 3. Input derating capacity referenced by curve 2. 4. All parameters not specified above are measured at rated load, 25°C of ambient temperature. 5. DC current is tested by 1500W, linear load at 13V, 26V, 52V input voltage. 6. The tolerance of each voltage value by models is:112/212 →±0.5V;124/224 →±1V;148/248 →±2V |