Meanwell 400W True Sine Wave DC-AC power star inverter/inverter charger/inverter welder
USD $100 - $120 /Piece
Min.Order:1 Piece
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | TS-400-148 | |
OUTPUT | RATED POWER | 400W |
MAXIMUM OUTPUT POWER | 460W for 180 sec. / 600W for 10 sec. / surge power 800W for 30 cycles(typ.) | |
AC VOLTAGE | Factory setting set at 110VAC | |
100 / 110 / 115 / 120VAC selectable by setting button S.W | ||
FREQUENCY | 60 ±0.1Hz 50/60Hz selectable by setting button | |
WAVEFORM | True sine wave (THD<3%) at rated input voltage | |
AC REGULATION Note.1 | ±3.0% at rated input voltage | |
FRONT PANEL INDICATOR | Operation status ; Green : normal, Orange(flashing) : remote control OFF, Red : abnormal | |
INPUT
| BAT. VOLTAGE | 48V |
VOLTAGE RANGE (Typ.) Note.3 | 42 ~ 60VDC | |
DC CURRENT (Typ.) | 10A | |
NO LOAD CURRENT DRAW (Typ.) | 0.32A | |
OFF MODE CURRENT DRAW | ≤1mA | |
EFFICIENCY (Typ.) Note.1 | 87% | |
BATTERY TYPES | Open & sealed Lead Acid | |
BATTERY INPUT PROTECTION | FUSE | 20A*1 |
BAT. LOW ALARM | 45± 4% | |
BAT. LOW SHUTDOWN | 42± 4% | |
BAT. POLARITY | By internal fuse open | |
OUTPUTPROTECTION | OVER TEMPERATURE | 75°C ± 5°C |
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH1 detect power transistor | ||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
GFCI PROCTECTION | Optional (Only type F) | |
FUNCTION | REMOTE CONTROL | Open : Normal work ; Short : Remote off |
ENVIRONMENT | WORKING TEMP. | -10~+40°C at 100% load +60°C at 50% load |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -30~+70°C / -22~ +158 F, 10~95%RH | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | Design refer to UL458 |
LVD | None | |
WITHSTAND VOLTAGE | Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |
ISOLATION RESISTANCE | Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH | |
| EMC EMISSION | Compliance to FCC class A |
EMC IMMUNITY | None | |
OTHERS | MTBF | 104.7K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 205*158*67mm (L*W*H) | |
PACKING | 1.73Kg; 6pcs/11.4Kg/1.55CUFT | |
NOTE | 1.Efficiency is tested by 300W, linear load at 13V/26V/52V input voltage. 2.AC regulation is tested at 13V/26V/52V input voltage. 3.The tolerance of each voltage value by models is:112/212→±0.5V;124/224→±1V;148/248→±2V |
hing power supply dual output switching power supply switchin