Meanwell 700W True Sine Wave DC-AC Power Inverter ac inverter
USD $1 - $10 /Piece
Min.Order:10 Pieces
Hangzhou Nuohan Electronics Co., Ltd.
MODEL | TS-700-248 | |
OUTPUT | RATED POWER | 700W |
MAXIMUM OUTPUT POWER | 800W for 180 sec. / 1050W for 10 sec. / surge power 1400W for 30 cycles | |
AC VOLTAGE | Factory setting set at 230VAC | |
200 / 220 / 230 / 240VAC selectable by setting button S.W | ||
FREQUENCY | 50 ±0.1Hz 50/60Hz selectable by setting buttonS.W | |
WAVEFORM | True sine wave (THD<3%) at rated input voltage | |
AC REGULATION (Typ.) | ±3.0% | |
SAVING MODE (Typ.) | Default disabled. Load≤5W will be changed to standby mode | |
FRONT PANEL INDICATOR | Battery voltage level, output load level, saving mode, fault and operation status | |
INPUT
| BAT. VOLTAGE | 48V |
VOLTAGE RANGE (Typ.) Note.3,5 | 42~ 60VDC | |
DC CURRENT (Typ.) | 19A | |
NO LOAD DISSIPATION | ≤6W at standby saving mode | |
OFF MODE CURRENT DRAW | ≤1mA | |
EFFICIENCY (Typ.) Note.1 | 91% | |
BATTERY TYPES | Open & sealed Lead Acid | |
BATTERY INPUT PROTECTION | FUSE | 20A*2 |
BAT. LOW ALARM | 45± 4% | |
BAT. LOW SHUTDOWN | 42± 4% | |
BAT. POLARITY | By internal fuse open | |
OUTPUTPROTECTION | OVER TEMPERATURE | 75°C ± 5°C |
Protection type : Shut down o/p voltage, re-power on to recover; by internal RTH3 detect on heatsink of power diode | ||
OUTPUT SHORT | Protection type : Shut down o/p voltage, re-power on to recover | |
OVER LOAD (Typ.) | 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. | |
Protection type : Shut down o/p voltage, re-power on to recover | ||
GFCI PROCTECTION | None | |
ENVIRONMENT | WORKING TEMP. Note.4 | 0~+40°C at 100% load +60°C at 50% load |
WORKING HUMIDITY | 20%~90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -30~+70°C / -22~ +158 F, 10~95%RH | |
VIBRATION | 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes | |
SAFETY&EMC | SAFETY STANDARDS | None |
LVD | EN60950-1 | |
WITHSTAND VOLTAGE | Bat. I/P - AC O/P:3.0KVAC AC O/P - FG:1.5KVAC | |
ISOLATION RESISTANCE | Bat. I/P-AC O/P, AC O/P-FG:100M Ohms / 500VDC / 25¢J/ 70% RH | |
| EMC EMISSION | Compliance to EN55022 class A, 72/ 245/ CEE, 95/ 54/ CE, E-Mark |
EMC IMMUNITY | Compliance to EN61000-4-2,3,8 | |
OTHERS | MTBF | 74.4K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 295*184*70mm (L*W*H) | |
PACKING | 3.8Kg; 2pcs/8.6Kg/1.27CUFT | |
NOTE | 1.Efficiency is tested by 530W, linear load at 13V, 26V, 52V input voltage. 2.All parameters not specified above are measured at rated load, 25°C of ambient temperature. 3.Input derating capacity referenced by curve 2. 4.Output derating capacity referenced by curve 1. 5.The tolerance of each voltage value by models is:112/212 →±0.5V;124/224 →±1V;148/248 →±2V |
hing power supply dual output switching power supply switching power supply 12v -12v