China manufacture Temperature Controller CD/CH Series CH702, Temperature controller/ Quality Choice
USD $3 - $30 /Piece
Min.Order:10 Pieces
Yueqing Yomin Electric Co., Ltd.
Hot Sales 3-12 Ways Indoor Waterproof TSM series Flush Mounted Distributing Box
Manufacturer 80 X 50 Water-proof Junction Box , Electronic Enclosure Electrical Suppliers
Good Quality Temperature controller Digital Economy Type Thermostat CD101, Terperature controller/
China manufacture Temperature Controller CHB702, Temperature controller/
Manufacturer 80X80X50 Water-proof Junction Box , Terminal Box Electrical Suppliers /
China manufacture Temperature Controller CD/CH Series CH702, Temperature controller/
Technical Data
Model Name |
1.Outline dimension | See the outline dimension picture | |
2.Control Mode | F:PID operation and auto calculating (reverse operation) | D:PID operation and auto calculating(Forward operation) |
W:eating/cooling PID operation and auto calculating(cooling water)*1 | A:heating/cooling PID operation and auto calculating(cooling water)*1 | |
3.Input mode | Refer to Input Range Table | |
4.Range Code | Refer to Input Range Table | |
5.First control output(OUT1) (Heating side) | M: Relay contact output V: Voltage impulse output T: Thyratron output | 8: Current output(IC4-20mA) G: Thyratron driving & triggering output |
6.Second control output( OUT2) (Cooling side)*2 | No mark: when the control mode is F or D M: Relay contact output V: Voltage impulse output | T: Thyratron output 8: Current output(IC 4-20mA) |
7.First alarm(ALM1) 8.Second alarm (ALM2)*2 | N: no alarm A: Upper-limit bias alarm B: Lower-limit bias alarm C: Upper/lower limit bias alarm D: alarm in area E: Standby upper-limit bias alarm attached F: Standby lower-limit bias alarm attached G: Standby upper/lower limit bias alarm H: Upper-limit input value alarm | J: lower-limit input alarm K: Standby upper-limit input alarm attached L: Standby lower-limit input alarm attached P: Heater breakage alarm(CTL-6)*3 S: Heater breakage alarm(CTL-12)*3 R: Control line breakage alarm *4 V: Upper-limit set value alarm W: Lower-limit set value alarm |
9.Communication*5 | N:No communication | 5:RS-485(two-wire system) |
10.Water-proof/dust-proof | N:no water-proof/dust-proof | 1:with water-proof/dust-proof |
Refer to Input Range Table |
Input type | Set range | Input type | Set range | |
Thermocouple Input(TC) | K | 0 to 1372°C(0 to 2502 F) | J | 0 to 1200°C(0 to 2192 F) |
R | 0 to 1769°C(0 to 3216 F) | S | 0 to 1769°C(0 to 3216 F) | |
B | 0 to 1820°C(0 to 3308 F) | E | 0 to 1000°C(0 to 1832 F) | |
N | 0 to 1300°C(0 to 2372 F) | T | -199.9 to +400.0°C(-199.9 to +752.0 F) | |
W5Re/W26Re | 0 to 2320°C(0 to 4208 F) | PL | 0 to 1390°C(0 to 2534 F) | |
L | 0 to 900°C(0 to 1652 F) | U | -199.9 to +600.0°C(-199.9 to +999.9 F) | |
RTD Input Pt | 100Ω(JIS/IEC) | -199.9 to +649.0°C (-199.9 to +999.9 F) | JPt100Ω(JIS) | -199.9 to +649.0°C (-199.9 to +999.9 F) |
Voltage input | 0 to 5V DC | 1 to 5V DC | -1999 to +9999(programmable range) | |
Current input | 0 to 20mADC | 4 to 20mADC | -1999 to +9999(programmable range0) |