CT&PT LCD DISPLAY THREE PHASE DIN RAIL ACTIVE AND REACTIVE ENERGY METER WITH BUILT-IN LITHIUM BATTERY
USD $62.09 - $63 /Piece
Min.Order:1 Piece
Yueqing Yomin Electric Co., Ltd.
20A 13Jaws/ 13J Single Phase Square Electric Meter Socket/Meter Base
Inserting Mounted Energy Meter/ Inserting Installed Three Phase Analog Energy Meter
Over 13 Years CE approved manufacture experience three phase din-rail analog electronic energy meter
Hot Selling !!!! 100A Single Phase Round Electric Meter Socket/Meter Base Quality Choice
NEW TYPE Single Phase Electronic Din Rail Active Energy Meter of LCD Display
2. Ten pole width (Modulus 12.5mm), complying with standard JB/T7121-1993.
3. 7 digits LCD display, 6+1 digits(999999. 1kWh),may select 5+2 digits display. (Please specified when ordering)
4. There is a maintenance-free lithium battery in it, use for displaying power cut reading.
5. Standard configuration one port of active pulse output passive and one port of reactive pulse output passive(polarity),The output rate are 0.01, 0.1, 1, 10kWh or kvarh/Pulse.Users can choose any one by themselves. May select one port of active pulse output passive and one port of reactive pulse output passive (nonpolarity). And contact with all kind of AMR system conveniently,Complying with standard IEC 62053-31 and DIN 43864. (Please specified when ordering)
6.Five LED instructions every power supply state and signal of active energy impulse and reactive energy impulse.
7. Automatic detection the direction of the flow of load current. And instructions by one LED.
8.Single direction three components measure three phase four wire active and reactive energy consumption. It is nothing with direction of the flow of load current. Complying with standard IEC 62053-21and IEC 62053-23.
9.Standard configuration type S wiring (Inlet from top, outlet from bottom), directly connect operation, may select use CT (Product Configuration code is LC) and PT&CT (Product Configuration code is KC) for operation.
10. Standard configuration short terminals cover, may select extension terminals cover, in order to protect to use safety. (Product Configuration code is MF).
Model |
Accuracy |
Reference Voltage(V) | Current specifications(A) | Starting current(A) | Insulation performance | ||
YEM421MC | Active class 1 Reactive class2 | 3×127/220 3×230/400 | 5(30) 10(60) 20(100) | 0.02 0.04 0.08 | AC voltage 4kv for 1 minute, 1.2/50us waveform impulse voltage 6kv |
Terminals | Note | ||||||
L1 | L1 phase line | ||||||
L2 | L2 phase line | ||||||
L3 | L3 phase line | ||||||
N | Neutral line | ||||||
7 and 8 | Port of active pulse output passive | ||||||
3 and 4 | Port of reactive pulse output passive | ||||||
1 and 2 | Port of stet SO pulse rate |