Guided wave radar level gauge
Negotiable /Piece
Min.Order:1 Piece
Shanghai Xingshen Instrument Co., Ltd.
RF2000B radar level measurement for top mounted coaxial probe
RF2000C guided wave radar precision level transmitter for level measuring instruments
RF2000D high precision digital level for guided wave radar top mounted dual probe (cable)
RF2030A guided wave radar level transmitter penetrating radar
RF2030C guided wave radar level transmitter penetrating radar for single probe flange top mounted
Recommend Use:water solution, crude oil, hydrocarbon fluids,hydrocarbon polymer
Not recommended:liquid sulfur,solid medium, high viscosity medium
Min. dielectric constant and Max. measure height:1.4→6m; 2.0→9m; 4.0→6m
Dielectric constant range: 1.4~100;medium viscosity: ≤1000cp
Technique parameter
Output signal : 4~20mA/HART
Voltage supply:11~28.6VDC (Intrinsically-safe type),11~36VDC (explosion-isolation type)
Nominal pressure: normal≤6.3MPa, high temperature≤32MPa
Medium density: normal temperature≤100°C,middle temperature≤210°C,high temperature≤520°C
Probe length : coax,rob≤6.1m, cable≤21m
Electric interface: factory setting M20×1.5, also can be made as per customer’s request.
Output accuracy|: analog:0.01mA; display:When measuring range < 10m Analog display is 1mm, when measuring range >10m is 10mm.
Precision: coaxial type 0.1%FS, other 5mm
Repetition: ≤2mm
Linearity: coaxial type/double rod:≤0.1% probe length
single rod:≤0.3% probe length
Temperature influence: probe length change (-0.02%) as temperature change.
Data updated: 30ms
Load resistance: ≤650Ω
Damping period: 0~32s adjustable
Fault-diagnosis, warning: 3.6mA,22mA,HOLD
User interface: 3 key +LCD display
Ambient temperature: -40~+60°C
RH: 0~99%
Protection rank: IP67
L | 316L(std) | Probe head material | ||||||
M | Monel alloy | |||||||
H | Hastelloy C-276 | |||||||
F | PTFE lined (for A and D only) | |||||||
G | Zirconium(Zr) | |||||||
T | Titanium (Ti) | |||||||
1 | 1.5''NPT | DN | ||||||
2 | 2''NPT | |||||||
3 | 1.5'' three-blade sanitary clamp | |||||||
4 | DN40(1.5'') | |||||||
5 | DN50(2.5'') | |||||||
6 | DN80(3'') | |||||||
7 | DN100(4'') | |||||||
8 | DN20 (for probe type A only) | |||||||
9 | DN25 (for probe type A only) | |||||||
| 0 | PN 2.5Mpa | Pressure rating | |||||
1 | PN 5.0Mpa | |||||||
2 | PN 6.4Mpa | |||||||
3 | PN 10Mpa | |||||||
4 | PN 16Mpa | |||||||
5 | Class 150LB ANSI | |||||||
6 | Class 300LB ANSI | |||||||
7 | Class 400LB ANSI | |||||||
8 | Class 600LB ANSI | |||||||
9 | Class 900LB ANSI | |||||||
| D | -50°C~204°C | Rated temperature | |||||
E | sanitary std tpe: -40°C~204°C | |||||||
H | -50°C~427°C | |||||||
| D | Explosion-proof: ExdIICT4~T6 | Ex-proof certificate | |||||
E | Intrinsic safe: ExiaIICT4~T6 | |||||||
| L | liquid level | Services | |||||
A | interface | |||||||
F | material level(powdery)measure | |||||||
P | material level (Tablet/particle) measure | |||||||
| mm | Measure span | ||||||
| mm | Mounting height |