2013 New Endress+Hauser differential pressure transmitter PMD70
Negotiable /Piece
Min.Order:1 Piece
Xian Wellwork Industrial Co., Ltd.
2013 New Endress+Hauser differential pressure transmitter PMD70
Differential pressure transmitter with ceramic sensor
Overload-resistant and function-monitored, Communication via HART, PROFIBUS PA or FOUNDATION Fieldbus
Your benefits
The Deltabar S differential pressure transmitter is used for the following measuring tasks:
Measuring Principle | Differential pressure | |
Characteristic | Digital transmitter with ceramic measuring diapragms Modular transmitter Long-term stability Enhanced safety via self diagnostic functions Secondary process barrier | |
Supply / Communication | 4...20mA HART: 10,5...45V DC Ex ia: 10,5...30V DC PROFIBUS PA / FOUNDATION Fieldbus: 9...32V DC | |
Accuracy | 0,075% "PLATINUM" 0,05% | |
Long term stability | 0,05% of URL/year 0,125% of URL/5 years | |
Process temperature | -20°C...85°C (-4°F...185°F) | |
Ambient temperature | -20°C...85°C (-4°F...185°F) | |
Measuring range | 25mbar...3bar (10inH2O...45psi) | |
Max. overpressure limit | on one side: 100 bar (1500 psi) | |
Process connection | 1/4-18NPT RC1/4" | |
Output | 4...20mA HART PROFIBUS PA FOUNDATION Fieldbus | |
Certificates / Approvals | ATEX FM CSA NEPSI IECEx SIL GL marine WHG/ Overfill prevention EN10204-3.1 | |
Options | HistoROM/M-Dat 4-line digital display SS- or Aluminium housing Separate housing | |
Specialities | diagnostic functions |