Jumper veterinary patient monitor
USD $300 - $900 /Unit
Min.Order:1 Unit
Shenzhen Jumper Medical Equipment Co., Ltd.
Jumper veterinary patient monitor
General instruction:
Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.
Features:
12" color TFT display, up to 12 waveforms
One level menu, easy to use
Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
Maximum 720 hour graphic and tabular trends of all parameters
Built-in recorder and battery
Suitable for adult, pediatric and neonatal patient
Arrhythmia analysis, ST calculation, Pace analysis
Anti-ESU, anti- defibrillator
Standard network interface, can connect to Central monitor system
Optinal: recorder, dual IBP, CO2, IoC
Specifications
ECG
Lead mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV, auto
Resolution 1 bpm
Sensitivity > 200 (uV P-P)
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential 300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range: 8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
5%±Calibration Signal 1 (mV p-p), Accuracy :
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R
ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available
RESPARATION
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 ~ 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy 2 rpm
Apean Alarm 10 ~ 40 S
NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STATMode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error 5mmHg
Maximum Standard deviation 8mmHg
Overpressure Protection
Adult Mode 297 3 mmHg
Pediatric Mode 240 3 mmHg
Neonatal Mode 147 3 mmHg
SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy
70% ~ 100% 2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy 2bpm
TEMPERATURE
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1 C
Accuracy 0.1 C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
IBP(Optional)
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy 2% or 1mmHg, which great
Actualization interval about 1 Sec.
ETCO2(Optional)
Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy : ±2 mmHg (< 5.0% Measurement Value)
±10%( > 5% Measurement Value)
Response Time: 180ms
SPO2 probe
TEMP probe
NIBP Cuff
ECG cable