Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

USD $500 - $600 /Unit

Min.Order:1 Unit

Supply Ability:
500 Unit / Units per Month
Port:
HongKong
Payment Terms:
T/T Credit Card

Quick Details View All >

Type:
Examination Therapy Equipments
Brand Name:
Jumper
Model Number:
JPD-800B
Place of Origin:
Guangdong, China

Shenzhen Jumper Medical Equipment Co., Ltd.

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: Fetal Doppler ,Fetal Monitor ,Pulse oximeter ,Blood pressure monitor ,Patient monitor

Product Details

Specifications

Monitor Patient
1.12.1 inch.
2.CE marked
3.ECG , Spo2 , PR , NIBP , RR , Temp.
4.Support 6 language.

Multi Parameter Patient Monitor

General instruction:

 

Portable Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient.  

 

Specifications

 

ECGMonitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Lead mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)

Lead selection I, II, III, avR, avL, avF, V,

Waveform 2 ch

Lead mode 3 Leads ( R, L, F or RA, LA, LL)

Lead selection I, II, III,

Waveform 1 ch

Gain: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV, auto

Resolution 1 bpm

Sensitivity > 200 (uV P-P)

Differential Input Impedance > 5 MΩ

CMRR

Monitor > 105 dB

Operation > 105 dB

Diagnosis > 85 dB

Electrode offset potential 300mV

Leakage Current < 10 uA

Baseline Recovery < 3 S After Defi.

ECG Signal Range: 8 m V ( Vp-p )

Bandwidth

Surgery 1 ~ 15 Hz

Monitor 0.5 ~ 35 Hz

Diagnostic 0.05 ~ 100 Hz

5%±Calibration Signal 1 (mV p-p), Accuracy :

ST Segment Monitoring Range

Measure and Alarm -2.0 ~ +2.0 mV

ARR Detecting

 

Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R

ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm Available

Review Available

 

RESP

Method Impedance between R-F(RA-LL)

Differential Input Impedance >2.5 MΩ

Measuring Impedance Range: 0.3~5.0Ω

Base line Impedance Range: 0 ~ 2.5 KΩ

Bandwidth 0.3 ~ 2.5 Hz

Resp. Rate

Measuring and Alarm Range

Adult 0 ~ 120 rpm

Neo/Ped 0 ~ 150 rpm

Resolution 1 rpm

Accuracy  2 rpm

Apean Alarm 10 ~ 40 S

 

NIBPMonitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Method Oscillometric

Mode Manual, Auto, STAT

Measuring Interval in AUTO Mode

1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)

Measuring Period in STATMode 5 Min

Pulse Rate Range 40 ~ 240 bpm

Alarm Type SYS, DIA, MEAN

Measuring and alarm range

Adult Mode

SYS 40 ~ 270 mmHg

DIA 10 ~ 215 mmHg

MEAN 20 ~ 235 mmHg

Pediatric Mode

SYS 40 ~ 200 mmHg

DIA 10 ~ 150 mmHg

MEAN 20 ~ 165 mmHg

Neonatal Mode

SYS 40 ~ 135 mmHg

DIA 10 ~ 100 mmHg

MEAN 20 ~ 110 mmHg

Resolution

Pressure 1mmHg

 

Accuracy

Pressure

Maximum Mean error  5mmHg

Maximum Standard deviation  8mmHg

Overpressure Protection

Adult Mode 297 3 mmHg

Pediatric Mode 240 3 mmHg

Neonatal Mode 147 3 mmHg

 

SpO2Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Measuring Range 0 ~ 100 %

Alarm Range 0 ~ 100 %

Resolution 1 %

Accuracy

70% ~ 100%  2 %

0% ~ 69% unspecified

Actualization interval about 1 Sec.

Alarm Delay 10 Sec.

PR

Measuring and Alarm Range

0~254bpm

Resolution :1bpm

Accuracy:  2bpm

TEMPMonitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Channel 1

Measuring and Alarm Range 0 ~ 50 C

Resolution 0.1 C

Accuracy  0.1 C

Actualization interval about 1 Sec.

Average Time Constant < 10 Sec.

IBP(Optional)

Label ART, PA, CVP, RAP, LAP, ICP, P1, P2

Measuring and alarm range

ART 0 ~ 300 mmHg

PA -6 ~ 120 mmHg

CVP/RAP/LAP/ICP -10 ~ 40 mmHg

P1/P2 -10 ~ 300 mmHg

Press Sensor

Sensitivity 5 uV/V/mmHg

Impedance 300-3000Ω

Resolution 1 mmHg

Accuracy 2% or 1mmHg, which great

Actualization interval about 1 Sec.

ETCO2(Optional)

Measure range: 0% - 13%

Resolution: 1 mmHg

Accuracy : ±2 mmHg (< 5.0% Measurement Value)

±10%( > 5% Measurement Value)

Response Time: 180ms

 

CE Certificate:

Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

About Us

Shenzhen Jumper Medical Equipment Company is a manufacture of medical equipment in China since 1998, with CE&FDA approved.

We have over 300 employees, cover an area of 8,000 M2

We are in the field of

-Fetal Doppler

-Fetal Monitor

-Patient Monitor

-Finger Pulse Oximeter

-Infrared Forehead Thermometer.

-Finger Pulse Oximeter.

Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

Monitor Patient,CE ,12.1inch,handheld touch screen,etco2,NIBP,wall mounting

If you feel good about our product, why don't you send an enquiry?

We promise to give you a reply in 24 hours.

If you did not find what you want,  Pls click here.

Contact Supplier

Ms. cherry huang Overseas Sales Manag Chat Now
Telephone
86-755-26696279-811
Mobile
18938093602
Fax
86-755-26852025
Address
7th to 10th FL.,East district ,No.71-4, Building D,Xintian Avenue,Fuyong street ,Baoan district ,Shenzhen,China Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Medical Devices > Emergency & Clinics Apparatus
Categories
Hi~