veterinary surgical monitor, multiparameter monitor CE ISO

veterinary surgical monitor, multiparameter monitor CE ISO

USD $300 - $900 /Unit

Min.Order:1 Unit

Supply Ability:
20 Unit / Units per Month
Port:
HK
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
Jumper veterinary monitor
Model Number:
JPD-800B VET
Properties:
Other, Diagnosis & Injection

Shenzhen Jumper Medical Equipment Co., Ltd.

Business Type: Manufacturer
Shenzhen Guangdong China
Main Products: Fetal Doppler ,Fetal Monitor ,Pulse oximeter ,Blood pressure monitor ,Patient monitor

Product Details

Specifications

1. 720 hours tabular and graphic trends of all parameters
2. connect to central monitoring system
3. built-in thermal recorder

veterinary surgical monitor, multiparameter monitor CE ISO

 

 veterinary surgical monitor, multiparameter monitor CE ISO

 

 

Features:

 12" color TFT display, up to 12 waveforms
One level menu, easy to use
Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
Maximum 720 hour graphic and tabular trends of all parameters
Built-in recorder and battery
Suitable for adult, pediatric and neonatal patient
Arrhythmia analysis, ST calculation, Pace analysis
Anti-ESU, anti- defibrillator
Standard network interface, can connect to Central monitor system
Optinal: recorder, dual IBP, CO2, IoC

 

Specifications

 

 ECG

Lead mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain: X2.5mm/mV, X5.0mm/mV, X10mm/mV, X20mm/mV, auto
Resolution 1 bpm
Sensitivity > 200 (uV P-P)
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential 300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range: 8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
5%±Calibration Signal 1 (mV p-p), Accuracy :
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting

 

Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R
ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available


RESPARATION
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 ~ 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy  2 rpm
Apean Alarm 10 ~ 40 S


NIBP
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STATMode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg

 

Accuracy
Pressure
Maximum Mean error  5mmHg
Maximum Standard deviation  8mmHg
Overpressure Protection
Adult Mode 297 3 mmHg
Pediatric Mode 240 3 mmHg
Neonatal Mode 147 3 mmHg


SpO2
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy
70% ~ 100%  2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy    2bpm


TEMPERATURE
Channel 1
Measuring and Alarm Range 0 ~ 50 C
Resolution 0.1 C
Accuracy  0.1 C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.


IBP(Optional)
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART 0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP -10 ~ 40 mmHg
P1/P2 -10 ~ 300 mmHg
Press Sensor
Sensitivity 5 uV/V/mmHg
Impedance 300-3000Ω

 

Resolution 1 mmHg
Accuracy 2% or 1mmHg, which great
Actualization interval about 1 Sec.


ETCO2(Optional)
Measure range: 0% - 13%
Resolution: 1 mmHg
Accuracy : ±2 mmHg (< 5.0% Measurement Value)
±10%( > 5% Measurement Value)
Response Time: 180ms

 

 

 

 

veterinary surgical monitor, multiparameter monitor CE ISO

SPO2 probe

 

veterinary surgical monitor, multiparameter monitor CE ISO

TEMP probe

 

veterinary surgical monitor, multiparameter monitor CE ISO

NIBP Cuff

 

veterinary surgical monitor, multiparameter monitor CE ISO

ECG cable  

Contact Supplier

Ms. cherry huang Overseas Sales Manag Chat Now
Telephone
86-755-26696279-811
Mobile
18938093602
Fax
86-755-26852025
Address
7th to 10th FL.,East district ,No.71-4, Building D,Xintian Avenue,Fuyong street ,Baoan district ,Shenzhen,China Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Health & Medical > Animal & Veterinary > Veterinary Instrument
Categories
Hi~