SMTSEC SVC-C368-18-USB supports VISCA/RS232/RS485 PTZ Control 18x optical zoom super Video performance video conference camera
Negotiable
Min.Order:1
Shenzhen Smart Technology Co., Ltd.
SMTSEC SVC-C368-18-USB supports VISCA/RS232/RS485 PTZ Control 18x optical zoom super Video performance video conference camera
SVC-C368-18-USB equipped with FCB-EX48EP Which is deliver 18x optical zoom super Video performance with 1/4 Exview CCD, it supports VISCA/RS232/RS485 PTZ Control. There are S-Video, AV video output and USB connect for optional, built in 360 degree continuously Pan movement, 90 degree Tilt and features with REV for up-side down installation. Which is Ideally suited for Web conferencing system, remote education, lecturing and Training room application. | ||
Features: | ||
S-Video/AV output | ||
Private Tooling design Color Video PTZ Camera | ||
Fast and smooth video handling | ||
Power ON-OFF switch | ||
Work & Standby LED indicator | ||
Speed Match | ||
Auto/Manual focus/brightness/WB | ||
RS-232C/VISCA Protocol | ||
Lens/Dome OSD | ||
Boundary scanning | ||
Standby & wakeup status | ||
Performance: | ||
1/4-type Exview HAD CCD | ||
550TVL 18x Optical, 12x digital zoom, f=4.1 mm to 73.8 mm, F1.4 to F3.0 | ||
12x (216x with optical zoom | ||
48 degree (wide) to 2.8 degree (tele) | ||
1.0 Lux/F1.4 | ||
USB Interface | ||
Pan 360 degree continuously | ||
Tilt +90 degree, -45degree | ||
64 preset positions | ||
4 cruise lines | ||
DC 12V, 2A | ||
Dimension: | ||
L 250mm x W 140mm x H154mm | ||
N. Weight: 2.6kgs | ||
G. Weight: 4.8kgs | ||
Installation: | ||
Desktop | ||
Ceiling mount | ||
Standard Tripod accessory | ||
Model Number | SVC-C368-18-USB | |
Image Sensor | Sensor | SONY FCB-EX48EP 1/4-type EXview HAD CCD |
Signal System | PAL/NTSC | |
Illumination | 1.0Lux/F1.4 | |
White Balance | Auto/Manual | |
Gain Control | Auto | |
Back-light | On /Off | |
compensation | ||
E-Shutter | 1 - 1/100,000s | |
Horizontal | 550 TVL | |
Resolution | ||
S/N Ratio | >50db | |
Lens | Focus | f=4.1-73.8 F1.4 -3.0 |
Iris | Auto/Manual | |
Zoom | 18x Optical X 12x Digital Zoom | |
Video Output | USB Output (Optional) | |
Control Decoder | Built-in decoder | |
Communication | EIA/RS422, EIA/RS232(Bidirectional) | |
Interface | ||
PTZ Control Protocol | VISCA, PELCO-P, PELCO-D(optional) | |
Baud Rate | 4800/9600bps | |
Patrol Lines | 4 Patrol Lines | |
Preset Position | 64 Preset Position | |
Power-off Protection | Saved scanning or patrol line settings Automatically Before power off | |
Speed Matching | Slow down camera Pan/Tilt movement speed while camera zooming in | |
OSD Menu | To change parameters of camera or camera module from OSD Menu | |
Image Auto Flip | Image Auto Flip | |
Pan Speed | 1-280 degree per second | |
Tilt Speed | 1-100 degree per second | |
Pan Rotation Angle | 360 degree continuously | |
Tilt Rotation Angle | 240 degree | |
Auto Pan Scan | Support auto pan scanning | |
Boundary Scan | 0-359 degree(programmable) | |
Remoter Control | IR wireless remote controller P/T/Z | |
Power Supply | DC12V±10%, 1.2A | |
Working Temperature | 0-50℃ | |
Environment Humidity | 0-95%RH | |
Size(LxWxH) | 124X120X145mm | |
Weight | 1300g | |
SMTSEC Video conference camera FAQ | ||
Symptom | Cause | Remedy |
The power of the camera is not turned on. | The supplied AC power adaptor is not connected to the DC IN 12V jack firmly, or the AC power cord is not inserted firmly into the AC power adaptor or the AC outlet. | Insert the power cord firmly as far as it will go. |
Not Turn On the Power switch as “ON”. | Turn On the Power switch as “ON”. | |
Insufficient frame rate detected | Cannot recognize USB 3.0 connection, but the USB 2.0 speed. | Make sure you connected USB 3.0 Cable, USB 3.0 connect, and firmly connect to USB 3.0 interface. |
Pan,tilt or zoom cannot be operated. | Any menu is displayed on the monitor screen. | Press the “Dome OSD” OR “Lens OSD” on the Camera remote control Unit to turn off the menu from the monitor screen. |
The panning or tilting range is limited | Pan/Tilt movement range is ± 45 degree. | |
The Remote Commander does not work. | The Camera Select button you pressed on the Remote Commander does not match the number set with the IR SELECT switch on the camera. | Press the Camera Select button corresponding to the IR SELECT SWITCH setting on the Camera. |
Used out of battery | Change new battery (AA x 2) | |
The VISCA control is not available with a computer connected to the camera. | The computer is not correctly connected to the camera. | Make sure the connection between the computer and camera is made correctly. |
Check that the VISCA control setting (RS-232C or RS-422) and the baud rate setting (9600 bps or 38,400 bps) are properly made with the BOTTOM switch on the bottom of camera and the COM Port which configured in your computer. | ||
The camera cannot be operated at all. | Pull out the plug of the power cord from the AC outlet, then reinsert it into the AC outlet after a while. |
China Post (10-30 days)
EMS (5-15 working days)
DHL (3-5 working days)
UPS (3-5 working days)
•The most reliable, affordable way of shipping method deponds on your address.
•Online tracking number will be emailed to buyer through email.
•We dont take any responsibility for any custom delay.
•All products have been checked and packaged in good condition before dispatch.
•All products have 1 year warranty.