Low Cost High Performance 3.27 M HD Video camera achieved 1080p@30 high quality images. Equipped with SONY 3x optical, 12x digital zoom lens with wide HorizontalView field, ideally for small-sized videoconference rooms, auditoriums, and classroom. DVI-I connector is suited for DVI-D analog component which provided high-quality digital display, and HD-SDI used for long distance transmission application. | ||
Features: | ||
cutting-edge High Definition PTZ camera | ||
Fast and smooth video handling | ||
Low cost design for marketing | ||
Power ON-OFF switch | ||
Work & Standby LED indicator | ||
Speed Match | ||
Auto/Manual focus/brightness/WB | ||
RS-232C/VISCA Protocol | ||
Lens/Dome OSD | ||
Boundary scanning | ||
Standby & wakeup status | ||
Swap video format | ||
DVI/HD-SDI Video output | ||
Performance: | ||
1/2.8" Type CMOS | ||
3.27 Megapixel | ||
0.25 Lux at F1.2 | ||
720P@30, 1080P@30 | ||
3x Optical x 12 digital zoom | ||
f=3.0 to 9mm F1.2-2.2 | ||
HOV 90° degree | ||
DSY Video output | ||
Pan : 0-355° | ||
Tilt: Up: 45°, Down: 45° | ||
64 preset positions | ||
4 cruise lines | ||
DC 12V, 2A | ||
Dimension: | ||
L 250mm x W 140mm x H154mm | ||
N. Weight: 1.23 kgs (only camera) | ||
G. Weight: 2.4 kgs (one unit) | ||
N.W Carton of 2 units: 2.6 kgs | ||
G. W Carton of 2 units:5.5 kgs | ||
Installation: | ||
Desktop | ||
Ceiling mount | ||
Standard Tripod accessory | ||
Model No. | SVC-HD 610-DSYC-SE600 | |
Image | Image Sensor | 1/2.8" Type CMOS |
Sensor | Effective Pix | 3.27 Megapixel |
Min. Illumination | 0.25 Lux at F1.2 | |
White balance | Auto/Manual/Indoor/Outdoor | |
Gain control | Auto | |
Backlight compensation | On/Off | |
Shutter speed | 1/5~1/10,000S | |
S/N ratio | >50db | |
Lens | Focus | f=3.00(wide) to 9mm(tele) F1.2-2.2 |
Iris | Auto/Manual | |
Lens | 3 Optical x 12 digital zoom | |
Horizontal view angle | 1080p:90 degree,720p:70 degree | |
Video output | DVI,CVBS,HD-SDI | |
Signal system | 720P@30,1080P@30 | |
Control terminal | EIA/RS232C,EIA/RS485(Bidirectional) | |
Control Protocol | VISCA,PELCO-D | |
baud rate | 9600/38400bps | |
patrol line | 4 cruise sequence | |
preset position | 64 preset positions | |
Speed Match | Pan/Tilt movement speed depends on camera module zoom in/out | |
OSD Menu | Access to OSD Menu and adjust camera module parameters | |
Image auto flp | Support Horizontal/Vertical image flip | |
Pan movement speed | 1-200°/Second | |
Tilt movement speed | 1-150°/Second | |
Pan movement range | Pan: 0-355° | |
Tilt movement range | Up: 45°, Down: 45° | |
Pan scanning automatically | Support Pan scanning automatically | |
Boundary scanning | 0-359° scanning (programmable) | |
Remote controller | IR Wireless Remote controller P/T/Z | |
Power supply | DC12V,2A | |
Work Temperature | 0-50℃ | |
Humidity | 0-95%RH | |
LxWxH | 250mm x 140mm x 145mm | |
Weight | 2.8 kgs | |
SMTSEC Video conference camera FAQ | ||
Symptom | Cause | Remedy |
The power of the camera is not turned on. | The supplied AC power adaptor is not connected to the DC IN 12V jack firmly, or the AC power cord is not inserted firmly into the AC power adaptor or the AC outlet. | Insert the power cord firmly as far as it will go. |
Not Turn On the Power switch as “ON”. | Turn On the Power switch as “ON”. | |
Insufficient frame rate detected | Cannot recognize USB 3.0 connection, but the USB 2.0 speed. | Make sure you connected USB 3.0 Cable, USB 3.0 connect, and firmly connect to USB 3.0 interface. |
Pan,tilt or zoom cannot be operated. | Any menu is displayed on the monitor screen. | Press the “Dome OSD” OR “Lens OSD” on the Camera remote control Unit to turn off the menu from the monitor screen. |
The panning or tilting range is limited | Pan/Tilt movement range is ± 45 degree. | |
The Remote Commander does not work. | The Camera Select button you pressed on the Remote Commander does not match the number set with the IR SELECT switch on the camera. | Press the Camera Select button corresponding to the IR SELECT SWITCH setting on the Camera. |
Used out of battery | Change new battery (AA x 2) | |
The VISCA control is not available with a computer connected to the camera. | The computer is not correctly connected to the camera. | Make sure the connection between the computer and camera is made correctly. |
Check that the VISCA control setting (RS-232C or RS-422) and the baud rate setting (9600 bps or 38,400 bps) are properly made with the BOTTOM switch on the bottom of camera and the COM Port which configured in your computer. | ||
The camera cannot be operated at all. | Pull out the plug of the power cord from the AC outlet, then reinsert it into the AC outlet after a while. | |
SMTSEC Video conference camera FAQ | ||
Symptom | Cause | Remedy |
The power of the camera is not turned on. | The supplied AC power adaptor is not connected to the DC IN 12V jack firmly, or the AC power cord is not inserted firmly into the AC power adaptor or the AC outlet. | Insert the power cord firmly as far as it will go. |
Not Turn On the Power switch as “ON”. | Turn On the Power switch as “ON”. | |
Insufficient frame rate detected | Cannot recognize USB 3.0 connection, but the USB 2.0 speed. | Make sure you connected USB 3.0 Cable, USB 3.0 connect, and firmly connect to USB 3.0 interface. |
Pan,tilt or zoom cannot be operated. | Any menu is displayed on the monitor screen. | Press the “Dome OSD” OR “Lens OSD” on the Camera remote control Unit to turn off the menu from the monitor screen. |
The panning or tilting range is limited | Pan/Tilt movement range is ± 45 degree. | |
The Remote Commander does not work. | The Camera Select button you pressed on the Remote Commander does not match the number set with the IR SELECT switch on the camera. | Press the Camera Select button corresponding to the IR SELECT SWITCH setting on the Camera. |
Used out of battery | Change new battery (AA x 2) | |
The VISCA control is not available with a computer connected to the camera. | The computer is not correctly connected to the camera. | Make sure the connection between the computer and camera is made correctly. |
Check that the VISCA control setting (RS-232C or RS-422) and the baud rate setting (9600 bps or 38,400 bps) are properly made with the BOTTOM switch on the bottom of camera and the COM Port which configured in your computer. | ||
The camera cannot be operated at all. | Pull out the plug of the power cord from the AC outlet, then reinsert it into the AC outlet after a while. |
China Post (10-30 days)
EMS (5-15 working days)
DHL (3-5 working days)
UPS (3-5 working days)
•The most reliable, affordable way of shipping method deponds on your address.
•Online tracking number will be emailed to buyer through email.
•We dont take any responsibility for any custom delay.
•All products have been checked and packaged in good condition before dispatch.
•All products have 1 year warranty.