The Newest Injection Mold Temperature Controller SF-205N1
Negotiable /Piece
Min.Order:50 Pieces
Zhongshan Shangfang Instrument Meter Co., Ltd.
We have 15 years experience producing temperature controller.Our products are well-known for their stable performance and durability.
Besides conventional products,customized are offered as well. So,do not hesitate to contact us,we will serve you with 100% enthusiasm
Satisfactory after-service is offered.Our technical team support you for any technical problem about products.And there is one year warranty for each one.
We ready to serve you. Let's build a win-win partnership!
Main products
Picture of company
Pictures of workshop
The Newest Injection Mold Temperature Controller SF-205N1
Features
1.temperature display and control
2.automatic defrost by electric heater or hot gas
3.door switch inspection alarm
4.high.low temperature alarm
Technical Data
1.range of temperature displayed:-45~150 °C
2.temperature sensor:3 pcs of NTC with 2 meters wire(cold room,defrost control,condenser high temperature alarm)
pressor:N.O.30A/250VAC(applicable to 1 HP compressor,if more it needs to connect an AC contactor)
defrost:N.O.30A/250VAC
evap.fan:N.O.30A/250VAC
Size
dimension:142 × 38 × 35mm
mounting hole dimension:137 ×31.5mm
Injection Mold Temperature Controller
Circuit Diagram
Parameter
Parameter | Function | Set range | Default |
E1 | Lower setpoint limit | -45 °C ~Set temp. | -30 °C |
E2 | Higher setpoint limit | Set temp.~50 °C | 30 °C |
E3 | Temp.hysteresis | 1~10 °C | 4 °C |
E4 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on roome temp. | -10 ~10 °C | 0 |
E6 | Offset on evap.temp. | -10 ~10 °C | 0 |
F0 | Defrost function | 0=Electric heater 1=Hot gas | 0 |
F1 | Max defrost duration | 1~60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 6Hr |
F3 | Defrost termination temp. | 0~50~0 °C | 8 °C |
F4 | Display during defrost | 0=Normal display 1=Last value before defrost | 0 |
F5 | Dripping time after defrost | 0~10Min | 2Min |
H1 | Fan start delay time | 0~10Min | 1Min |
H2 | Fan operating function | 0=Parallel with comp. 1=continuous running except defrosting | 0 |
H3 | Fan control during defrosting | 0=Always OFF 1=Always ON | 0 |
C2 | High temperature alarm | C3~130 °C | 40 °C |
C3 | Low temperature alarm | -45 °C~C2 | -40 °C |
C4 | Cold room alarm delay time | 1~90~1Min | 60Min |
C5 | Condenser high temp.alarm value | 0~130 °C | 80 °C |
C6 | Condenser high temp.alarm delay time | 1~60~1Min | 5Min |
C7 | Door alarm delay time | 1~60~1Min | 5Min |