SF-406 Electronics Microcomputer Thermostat Temperature Controller Cold Room Temperature Regulator
Negotiable /Piece
Min.Order:50 Pieces
Zhongshan Shangfang Instrument Meter Co., Ltd.
Digital temperature Controller for SF-406
Usage: Refrigeration.
Defrost type can be selected:
Defrost by turning off the compressor
Defrost by electric heater
Defrost by hot gas
Feature
1.Enter parameter adjust by password
2.Built-in transformer,built-in 4 relays
3.Defrost type(defrost by turning off compressor/electric heater/hot gas)
4.Evap.fan start-up modes selection
5.Defrost interval time modes selection(power-on time and compressor continous working time)
6.High low temperature alarm,condenser high temperature alarm
7.Door switch detection,alarm output,energy-saving
Technical Data
1.Rnage:-45~99°C(-45~150°F) Accuracy:±1°C
2.Compressor:30A/250VAC
Defrost:10A/250VAC
Evap.fan:5A/250VAC
Alarm output:5A/250VAC
3.Sensor: NTC, EXTERNAL, 2 pieces
4.Dimension:77*35*70mm
Mounting hole dimension:71*29mm
Parameter
Code | Function | Set range | Default |
PAS | Password | 00~99 | |
E1 | Lower setpoint limit | -50°C/-50°F~Set temp. | -25°C/-13°F |
E2 | Higher setpoint limit | Set temp.~45°C(113°F ) | 20°C/68°F |
E3 | Temp.hysteresis | 0.1~40.0°C 0.2~72.0 °F | 4.0°C/7.2°F |
E40 | Turn on delay starting time | 0~10Min | 2Min |
E41 | Comp.start delay time | 0~10Min | 2Min |
E5 | Offset on room temp. | -20~20°C -36~36°F | 0°C/0°F |
E6 | Offset on evap. temp. | -20~20°C -36~36°F | 0°C/0°F |
E7 | Offset on condenser temp. | -20~20°C -36~36°F | 0°C/0°F |
F0 | Defrost type | 0=defrost by turning off 1=electric heater 2=hot gas | 0 |
FF0 | Comp.delay when hot gas defrost | 00~20Min | 00Min |
FF1 | Defrost type | 0=power on time 1=compressor continuous working time | 0 |
F1 | Max.defrost duration | 1~60Min | 20Min |
F2 | Defrost interval time | 0~24Hr | 6Hr |
F30 | Defrost starting temp. | -40°C/-40°F~F31 | 0.0°C/32°F |
F31 | Defrost temination temp. | F30~40.0°C/104°F | 8.0°C/46.4°F |
F4 | Display during defrost | 0=Normal display 1=Last value before defrost 2=Display"DEF" | 1 |
F5 | Dripping time | 0~60Min | 2Min |
P1 | Fan control during refrigeration | 0=synchronize with the compressor 1=work all the time 2=determined by P4,P5 | 0 |
P2 | Fan control during defrost | 0=off 1=on 2=determined by P4,P5 | 0 |
P3 | Fan starting mode after defrost | 0=time 1=determined by P4,P5 | 0 |
P4 | Fan starting temperature(defrost probe lower than starting) | -30°C/-22°F~P5 | 15.0°C/59.0°F |
P5 | Fan terminate temperature(defrost probe higher than starting) | P4~30°C/86°F | 25.°C/77.0°F |
P6 | Fan delay starting time after defrost | 00~30Min | 2Min |
C1 | Cold-room High temp.alarm | C2~45°C/113°F~OFF | 40.0°C/104°F |
C2 | Cold-room Low temp.alarm | OFF~45°C/45°F~C1 | -40°C/40°F |
C3 | Condenser high temperature alarm value | OFF~-40°C/-40°F~150°C/302°F | OFF |
C4 | Alarm hysteresis | 0.1~20.0°C/0.2~36.0°F | 2.0°C/3.6°F |
C5 | Effective outer alarm input work mode | 0=comp.stop running 1=according to C7.C8 | 00 |
C6 | After delay alarm | 0~120Min | 2Min |
C7 | Comp.force stop time | 0~120Min | 15Min |
C8 | Comp.force running time | 0=Compressor stop 1~120min=starting time | 30Min |
CF | Temperature unit | Celsius=°C Fahrenheit=°F | °C |
D1 | Display type | 0=Display current cold temp.actual value 1=Display not over"set temp.+E3+D2" 2=Fixed display set temp. | 00 |
D2 | Display increment | 00~30.0°C/00~54.0°F | 5.0°C/9.0°F |
Db | Display resolution | 0.1/1 °C/°F | 0.1 |
dor | Input type | 1=door switch(door open contact suction and close) 2=door switch(door open contact disconnected) 3=alarm input(contact disconnected alarm) 4=alarm input(contact suction and close alarm) | 01 |
do1 | Door open overtime alarm | 00~30Min | 5Min |
do2 | Fan status when door open | 00=stop 01=Original state | 00 |
do3 | Light status when door open | 00=normal display 01=Original state | 00 |
do4 | Temperature display when door open | 00=normal display 01~99=lock display time | 5Min |
L1 | Door open energy saving mode | 00=effective 01=ineffective(dor=1,2 effective) | 00 |
L2 | Energy saving triggering time | 01~20Hr (continuously door not open time) | 2Hr |
L3 | Energy saving set temp.increment | 00~30.0°C/00~54.0°F | 5.0°C/9.0°F |
L4 | Exit energy saving mode(door open time/hour) | 1~5 times | 1 times |
Dear friend,
We are a temperature controller supplier with good reputation in China, we have our own technical team and production line.
Our Advantages:
1.Rich experience. We have been specialized in digital temperature controller for 15 years.
2. Customer-centric. We have our own technical team and production line. We design and manufacture the products according to customers’ requirements.
3. High quality & reasonable price. We develop high quality products with 15 years endeavor. Our products are CE, CQC, UL, ROHS, TUV approved.
Many different function, appearance and price temperature controllers are supplier.
Any of our products your are interested, please do not hesitate to contact me!
It is my honor to provide our products and service to you!