Calinmeter cheap DLMS AMI AMR system Energy meter Data Concentrator Quality Choice
USD $100.00 - $100.00 /Piece
Min.Order:10 Pieces
Shenzhen Vlinstar Electronic Technology Co., Ltd.
DIN Rail STS Keypad Prepaid Energy meter and CIU (PLC communication)
Three Phase Four Wire STS Split Keypad Prepaid Energy meter(2-wires Communication)
Three Phase Four Wire STS Split Keypad Prepaid Energy meter(wireless PLC Communication)
Three Phase Four Wire STS Split Keypad Prepaid Energy meter(wireless RF Communication)
Single Phase Two Wire STS Split Keypad Prepaid Energy meter(wireless RF Communication)
Single Phase Two Wire STS Split Keypad Prepaid Energy meter(wireless PLC Communication)
Calinmeter cheap DLMS AMI AMR system Energy meter Data Concentrator
Main Features
Data transfer communication for GPRS, Ethernet
Direct connection for RS-485 serial port
Direct connection for USB
Infrared communication mode
Direct connection for RS-485 serial port*3
Real-time meter reading
Reading daily frozen energy
Reading historical daily & monthly consumption
Reading event
Reading meter parameter, status, and real-time data
Remote switch on &off
Prepaid & energy threshold control
Setting & record abnormal events: Power-down, Programing, Cover opening, Terminal cover opening, Reverse power, Phase Fail. The records include data and time
1024 Meter database capacity
2 months capacity for storing daily frozen data in meter
12 months capacity for storing monthly consumption in meter
Temporarily storing real-time reading data
Auto-detect and recovery
Terminal initialization
Remote transmission
Resuming broken transmission
Technical parameters:
Electrical parameters: | |
Voltage | |
Nominal voltage Un | 220V |
Extended operating voltage range | 80%~115%Un |
Limited voltage | 70%~120%Un |
Frequency |
|
Nominal frequency fn | 50Hz |
tolerance | -6%~2% |
Current |
|
Basic current(Ib) | 1.5(6)A |
Maximum current(Imax) | 6A |
Starting current(Ist) | 3mA |
Active energy constant | 6400imp/kWh |
Measurement Accuracy |
|
Active energy | 1% |
Reactive energy | 2% |
Power Consumption |
|
Power consumption in Voltage circuit | <10W <8VA |
Power consumption in current circuit | <1VA |
Temperature range |
|
Working temperature | -30℃ to+70℃ |
Limited working temperature | -40℃ to+80℃ |
| |
Insulation strength | |
AC Insulation strength | 4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections | 8kV |
|
|
Electro Magnetic Compatibility | |
Electrostatic discharges |
|
Contact discharge | 8kV |
Air discharge | 16kV |
Electromagnetic RF fields |
|
27MHz to 500MHz typical | 10V/m |
100kHz to 1GHz typical | 30V/m |
Fast transient burst test | 4kV |
|
|
Mechanical requirements |
|
Meter shell Protection Rate | IP51 |
Protection | classII |