DCU DLMS AMI AMR system data concentrator
USD $190.00 - $190.00 /Piece
Min.Order:10 Pieces
Shenzhen Vlinstar Electronic Technology Co., Ltd.
Low cost DLMS AMI AMR system electircity meter Data Concentrator
Three Phase STS Split Keypad Prepaid electricity meter(2-wires Communication)
Single Phase STS Split Keypad Prepaid electricity meter(wireless RF Communication)
Three Phase STS Split Keypad Prepaid electricity meter(wireless RF Communication) Quality Choice
Single Phase STS Split Keypad Prepaid Electricity meter(wireless PLC Communication)
Main Features
Data transfer communication for GPRS, Ethernet
Direct connection for RS-232 serial port
Direct connection for RS-485 serial port, capable for cascade
Infrared communication mode
Communication mode of power line carrier
RS-485communication mode
Real-time meter reading
Reading daily frozen energy
Reading historical daily & monthly consumption
Reading event
Reading meter parameter, status, and real-time data
Remote switch on &off
Prepaid & energy threshold control
Key operation for parameter setting & inquiry
Setting & record abnormal events: Power-down, Programing, Cover opening, Terminal cover opening, Reverse power, Phase Fail. The records include data and time
1024 Meters database capacity
2 months capacity for storing daily frozen data in meter
12 months capacity for storing monthly consumption in meter
Temporarily storing real-time reading data
Auto-detect and recovery
Terminal initialization
Remote transmission
Resuming broken transmission
Technical parameters:
Electrical parameters: | |
Voltage | |
Nominal voltage Un | 220V/380V |
Extended operating voltage range | 80%~115%Un |
Limited voltage | 70%~120%Un |
Frequency |
|
Nominal frequency fn | 50Hz |
tolerance | -6%~2% |
Current |
|
Basic current(Ib) | 1.5(6)A |
Maximum current(Imax) | 10A |
Starting current(Ist) | 3mA |
Active energy constant | 6400imp/kWh |
Measurement Accuracy |
|
Active energy | 1% |
Reactive energy | 2% |
Power Consumption |
|
Power consumption in Voltage circuit | <10W <8VA |
Power consumption in current circuit | <1VA |
Temperature range |
|
Working temperature | -35℃ to+70℃ |
Limited working temperature | -40℃ to+75℃ |
| |
Insulation strength | |
AC Insulation strength | 4kV at 50Hz during 1min |
Impulse voltage 1.2/50μs mains connections | 8kV |
|
|
Electro Magnetic Compatibility | |
Electrostatic discharges |
|
Contact discharge | 8kV |
Air discharge | 16kV |
Electromagnetic RF fields |
|
27MHz to 500MHz typical | 10V/m |
100kHz to 1GHz typical | 30V/m |
Fast transient burst test | 4kV |
|
|
Mechanical requirements |
|
Meter shell Protection Rate | IP51 |
Protection | classII |