Single Phase Two Wire STS Split Keypad Prepaid Energy meter with RS485 communication
USD $30.00 - $35.00 /Piece
Min.Order:100 Pieces
Shenzhen Vlinstar Electronic Technology Co., Ltd.
Single Phase Two Wire STS Split Keypad Prepaid
Energy meter with RS485 communication
Main Features
Total and time-sharing forward active & reactive energy measurement
Total and time-sharing reverse active & reactive energy measurement
Save last one to sixteen months energy data
Credit data transfered from a point of sale (POS) or vending system is made into a numeric token in a 20 digit number using the Standard Transfer Specification (STS) encryption techniques, which comply with IEC62055 protocol
When the residual energy is 0 or the allowable overdraft that both sides agreed, this meter will send out power-off signal to have load switch cut off power. The power will be recovered automatically after inputting new purchased energy amount.
The meter can be programmed for setting user credit warning threshold, When the meter’s residual energy is equal to credit warning threshold, the meter will start the audio & video warning function in a way of warning light flashing
With event recording function (including cover-opening event, tamper event and power failure event)
Communication standards IEC62056-21 protocol, 1200bps for communication
Communication standards IEC62056(DLMS/COSEM) protocol
2400bps for communication
Number of digits value field Up to 8
Digit size 4x10mm
Wired: Pair cable communication
Technical parameters:
Electrical parameters: | |
Voltage | |
Nominal voltage Un | 230V |
Extended operating voltage range | 80%~115%Un |
Limited voltage | 70%~120%Un |
Frequency |
|
Nominal frequency fn | 60Hz |
tolerance | 5% |
Current |
|
Basic current(Ib) | 5A |
Maximum current(Imax) | 80A |
Starting current(Ist) | 20mA |
Active energy constant | 1600imp/kWh |
Measurement Accuracy |
|
Active energy to IEC62053_21 | Class1.0 |
Reactive energy to IEC62053_23 | Class2.0 |
Power Consumption |
|
Power consumption in Voltage circuit | <2W <8VA |
Power consumption in current circuit | <1VA |
Temperature range |
|
Operation meter | -25℃ to+70℃ |
Storage | -40℃ to+85℃ |
| |
Insulation strength | |
AC Insulation strength | 4kV at 50Hz during 1min |
Impulse voltage 1.2/50 μs mains connections | 8kV |
|
|
Electro Magnetic Compatibility | |
Electrostatic discharges |
|
Contact discharge | 8kV |
Air discharge | 16kV |
Electromagnetic RFfields |
|
27MHz to 500MHz typical | 10V/m |
100kHz to 1GHz typical | 30V/m |
Fast transient burst test | 4kV |
|
|
Mechanical requirements |
|
Meter shell Protection Rate | IP54 |
Protection | classII |