10 years factory temperature humidity atmospheric chamber
USD $4,200 - $7,500 /Set
Min.Order:1 Set
Wuxi Harris Environment Equipment Co., Ltd.
Temperature humidity atmospheric chamber is simulation under the condition of product in humid
climate environment combination (high and low temperature operation & storage, temperature cycle, high temperature and high humidity, low temperature and humidity and condensation test, etc.), check whether the adaptability and characteristics of the product itself.
Does need to be met the requirements of international standard (IEC, JIS, GB, MIL...).International quantum measurement procedures in order to achieve consistency (including test steps, conditions, methods) to avoid different cognitive, and narrowing the scope of measurement uncertainty.
Equipment specification | THS-100UA | THS-150UA | THS-250UA | THS-500UA | THS-010UA | |||||
Workroom Dimensions (cm) | 50x40x50 | 50x50x60 | 60x60x70 | 80x70x90 | 100x100x100 | |||||
Temperature Range | A: -20°C-150°C B: -40°C-150°C C: -60°C-150°C D: -70°C-150°C | |||||||||
Fluctuation/Evenness | ±0.5°C/±2°C | |||||||||
Humidity Range | 20%~98%RH | |||||||||
Humidity Deviation | -2%~-3% | |||||||||
Temperature Rise Speed | 1.0°C~3.0°C/min | |||||||||
Temperature Down Speed | 0.7°C~1.2°C/min | |||||||||
Time needed for heating | RT°C~150°C≤30min | |||||||||
Time needed for cooling | RT°C~-40°C≤60min | |||||||||
The machine noise | ≤72 dB(A) | |||||||||
Load on the largest | ≤20kg | |||||||||
Equipment installed power | ~3.25KW | ~3.55KW | ~3.95KW | ~5.5KW | ~6.25KW | |||||
material | The studio:# SUS 304 stainless steel | The outer wall:Cold plate coating/#SUS304 | ||||||||
Wind Cycling Way | Centrifugal fan-broadband type forced air circulation | |||||||||
Refrigeration Way | Single stage compression refrigeration | |||||||||
Refrigerater | French Tecumseh | |||||||||
Refrigerants | R4O4A USA Dupont environmental protection refrigerant | |||||||||
Condensing Way | Air-cooled or water-cooled | |||||||||
Heater | Nickel chrome heating wire heater | |||||||||
Humidifier | Semi-closed steam and wet | |||||||||
Water Suplying Way | Automatic cycling water supply | |||||||||
Control instrument | TEMI880 or OYO-8256P or HLS950 | |||||||||
Design criteria | GB/T2423/5170/10586 JIS C60068 ASTM D4714 CNS3625/12565/12566 | |||||||||
Standard Accessories | 1 Observe window(double-deck cavity toughened glass), 1 50mm test hole in the left, 1 PL inner chamber lamp, 2 The sample is put aside frame 1 bag of wet and dry bulb, 3 fuses, 1 power line. | |||||||||
Safety device | Non- fuse-switch(compressor overload, refrigerant high low voltage, over-humidity and temperature protection, Protection switch,fuse stoppage warning system |
Applications: