10 years factory humidity and temperature chamber OEM acceptable
10 years factory humidity and temperature chamber OEM acceptable
10 years factory humidity and temperature chamber OEM acceptable
10 years factory humidity and temperature chamber OEM acceptable
10 years factory humidity and temperature chamber OEM acceptable
10 years factory humidity and temperature chamber OEM acceptable

10 years factory humidity and temperature chamber OEM acceptable

USD $23,500 - $50,000 /Set

Min.Order:1 Set

Supply Ability:
30 Set / Sets per Month
Port:
Shanghai
Payment Terms:
T/T L/C D/P D/A Credit Card

Quick Details View All >

Place of Origin:
Jiangsu, China
Brand Name:
Harris
Model Number:
TGDW-100UA
Power:
Electronic
Usage:
Other, Universal Testing Machine, material temperature test

Wuxi Harris Environment Equipment Co., Ltd.

Business Type: Manufacturer,Trading Company
Wuxi Jiangsu China
Main Products: Constant temperature and humidity box ,High and low temperature test chamber ,High and low temperature impact test chamber ,Constant temperature and humidity machine ,Xenon lamp aging box

Product Details

10 years factory humidity and temperature chamber OEM acceptable

Product Description

 

We are a member of Alibaba Trade Assurance, which can provide you with a set of features and protections to help ensure suppliers honor important details of your contract such as on-time delivery and promised quality.

 

Our advantage:

A. Main components and parts are world famous brand,like Japan ORO controller, French Tecumseh (Refrigerator),Danmark danfoss expansion valve ,Omron intermediate relay, Schneider solid state relay and so on.

B. User friendly three color LED indicator lamp ,easy to read working condition

C. Leading deep refrigeration technology in China ,lowest temperature can reach -120°C.

D. Anti-condensation technology of the workroom .(Optional)

E. SMS remote fault notification (Optional)

F. Multi-points sensor protection (overheat ,lack water ,high/low pressure of refrigerator ,anti-parch, overload,etc.)

G. Self-diagnose of system error.

 

This humidity and temperature chamber  is simulation under the condition of product in humid climate 

environment combination high and low temperature operation & storage, temperature cycle, high temperature and high humidity, low temperature and humidity and condensation test, etc.), check whether the adaptability and characteristics of the product itself.

Does need to be met the requirements of international standard (IEC, JIS, GB, MIL...).International quantum measurement procedures in order to achieve consistency (including test steps, conditions, methods) to avoid different cognitive, and narrowing the scope of measurement uncertainty.

 

humidity and temperature chamber

Equipment specification

THS-100UA

THS-150UA

THS-250UA

THS-500UA

THS-010UA

Workroom Dimensions (cm)

50x40x50

50x50x60

   60x60x70

80x70x90

100x100x100

Temperature Range

A: -20°C-150°C      B: -40°C-150°C     C: -60°C-150°C  D: -80°C-150°C

Fluctuation/Evenness

±0.5°C/±2°C

Humidity Range

10%~98%RH(20%~98%RH)

Humidity Deviation

2%~-3%

Temperature Rise Speed

1.0°C~3.0°C/min

Temperature Down Speed

0.7°C~1.2°C/min

Time needed for heating

RT°C~150°C≤30min

Time needed for cooling

RT°C~-40°C≤60min

The machine noise

72 dB(A)

Load on the largest

≤20kg/layer

Equipment installed power

~3.25KW

~3.55KW

~3.95KW

~5.5KW

~6.25KW

material

The studio:# SUS 304 stainless steel

The outer wall:Cold plate coating/#SUS304

Wind Cycling Way

Centrifugal fan-broadband type forced air circulation

Refrigeration Way

Single stage compression refrigeration

Refrigerater

French Tecumseh

Refrigerants

R4O4A USA Dupont environmental protection refrigerant

Condensing Way

Air-cooled or water-cooled

Heater

Nickel chrome heating wire heater

Humidifier

Semi-closed steam and wet

Water Suplying Way

Automatic cycling water supply

Control instrument

TEMI880 or OYO-8256P or HLS950

Design criteria

GB/T2423/5170/10586  JIS C60068  ASTM D4714  CNS3625/12565/12566

Standard Accessories

1 Observe window(double-deck cavity toughened glass),

1  50mm test hole in the left,

1  PL inner chamber lamp,

The sample is put aside frame

1 bag of wet and dry bulb,

3 fuses, 

1 power line.

Safety device

Non- fuse-switch(compressor overload, 

refrigerant high low voltage,

over-humidity and temperature protection,

Protection switch,fuse stoppage warning system

 

 

 


 
 

 

Packaging & Shipping

 10 years factory humidity and temperature chamber OEM acceptable10 years factory humidity and temperature chamber OEM acceptable

Company Information

 10 years factory humidity and temperature chamber OEM acceptable

 

FAQ

 10 years factory humidity and temperature chamber OEM acceptable

 

Contact Supplier

Mr. peter ren Chat Now
Telephone
86-510-66725941
Mobile
13812046315
Address
High road no. 11 Wuxi,Jiangsu

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~