This climatic temperature test instrument is also known as hot and cold impact testing machine, used to test or composite
material structure, in an instant by the extremely high temperature and low temperature under continuous environment can endure degree, in order to test in the shortest possible time chemical changes caused by heat bilges cold shrink or physical damage. Applicable to metal and plastic, rubber, electronic...Such as material, can be used as the basis of its product improvements or reference.
| |||||||||||||||||||||
Specification | TGDW-100UA | TGDW-150UA | TGDW-250UA | TGDW-500UA | TGDW-010UA | ||||||||||||||||
Workroom Sizes W*D*H (cm) | 50x40x50 | 50x50x60 | 60x60x70 | 80x70x90 | 100x100x100 | ||||||||||||||||
Inner chamber volume(V) | 100L | 150L | 252L | 504L | 1000L | ||||||||||||||||
Outer dimension W*D*H(cm) | 98x95x160 | 98x105x170 | 108x112x180 | 128x125x200 | 148x155x210 | ||||||||||||||||
Packing Size | 113x110x175 | 113x120x185 | 123x127x195 | 133x140x215 | 163x160x225 | ||||||||||||||||
G.W(kg) | 340 | 370 | 430 | 460 | 600 | ||||||||||||||||
Temperature Range | A: -20°C-150°C B: -40°C-150°C C: -60°C-150°C D: -80°C-150°C | ||||||||||||||||||||
Temperature Fluctuation | ≤±0.5°C(standard)/≤±0.2°C(optional) | ||||||||||||||||||||
Temperature Evenness | ≤±2°C | ||||||||||||||||||||
Temperature Deviation | ≤1°C | ||||||||||||||||||||
Accuracy | 0.1°C(standard)/0.01℃(optional) | ||||||||||||||||||||
Temperature Rise Speed | 1.0°C~3.0°C/min | ||||||||||||||||||||
Temperature Down Speed | 0.7°C~1.2°C/min | ||||||||||||||||||||
Time needed for heating | RT°C~150°C≤30min | ||||||||||||||||||||
Time needed for cooling | RT°C~-40°C≤60min | ||||||||||||||||||||
The machine noise | 72 dB(A) | ||||||||||||||||||||
Load on the largest | 100kg,≤20kg/layer | 150kg,≤26kg/layer | 260kg,≤30kg/layer | 260kg,≤40kg/layer | 300kg,≤60kg/layer | ||||||||||||||||
Equipment installed power | ~1.95KW | ~2.35KW | ~2.85KW | ~3.5KW | ~4.35KW | ||||||||||||||||
material | Inner chamber:# SUS 304 stainless steel | The outer wall:A3 carbon steel plate with plastic spray/#SUS304 | |||||||||||||||||||
Wind Cycling Way | Centrifugal fan forced air circulation | ||||||||||||||||||||
Refrigeration Way | Single stage compression refrigeration | ||||||||||||||||||||
Refrigerater | French Tecumseh | ||||||||||||||||||||
Refrigerants | R4O4A USA Dupont environmental protection refrigerant | ||||||||||||||||||||
Condensing Way | Air-cooled or water-cooled | ||||||||||||||||||||
Heater | Nickel chrome heating wire heater | ||||||||||||||||||||
Controller | Japan OYO/Korea Temi | ||||||||||||||||||||
Design criteria | GJB150.3 GJB150.4 GB/T2423.22 GB10589-89 GB11158-89 | ||||||||||||||||||||
Standard Accessoriesparts | 1 Observe window(double-deck cavity toughened glass),50mm testing hole,PL internal bulbs,partition plate,dry and wet ball gauze,3 fuses,1 power line | ||||||||||||||||||||
Safety device | Compressor overload protection, fuse protection, Overheat protection ,high/low pressure of refrigerator ,over-humidity and temperare protection,over-current protection,Over-current circuit breaker,earth leakage protection | ||||||||||||||||||||