CVI-1200 system
Negotiable /Set
Min.Order:1 Set
Shanghai Jinwei Instrument Manufacturing Co., Ltd.
Product introduce:
CVI-1200 system is composed of high temperature tube furnace, vacuum pressure control system, over-voltage protection and condensation. It can do mixed gas chemical vapor deposition and diffusion experiment. And vacuum can reach 0.1 mabr.
Main function and Features:
1. In high temperature experimental process, can work with the pressure control device to achieve precise control of negative pressure;
2. Digital mass flow control system is proposed of multi-channel mass flow meter, flow indicator and other components. It can obtain precision measurement and control of gas flow; Each gas pipes are equipped with high-pressure check valve, to ensure the safety, continuous and uniform of protection, reduction, replacement atmosphere gas in the quartz tube.
3. The exhaust volatiles minus 20 degrees condenser deposition, in order to do the collection and processing .
4. Adopted KF fast sealing flange, convenient loading and unloading; Pipeline used the world's top Swagelok ferrule connections, no leakage.
5. When over temperature, overvoltage will automatically cut off the heating power and stop inlet gas. Used more safe and reliable.
Main uses:
Universities, research institutes, industrial and mining enterprises to do high-temperature atmosphere sintering, atmosphere restoring and CVD / CVI experiment, especially suitable for vacuum coating, nano- film material producing and Chemical vapor infiltration of carbon fiber composite materials.
Technical Parameter:
SGL-1200L | Temperature control mode | The temperature control system uses artificial intelligence technology, with PID control, self - tuning function , 30 the heating and cooling program |
| Heating elements | 0Cr27Al7Mo2 |
Power supply | AC220V 50HZ/60HZ | |
Rated power | 4KW | |
Tube size | Φ60/80/100*800mm | |
Working temp | ≤1150C | |
Max temp | 1200C | |
Constant heating zone length | 100mm(customized) | |
accuracy | ±1C | |
Heating rate | ≤20C/min | |
Temperature | N-type thermocouple | |
Seal type | Stainless steel water cooling KF flange rapid extrusion seal | |
MV2NT VARIO | ultimate vacuum | 0.1mabr |
Configuration | Vacuubrand four diaphragm pump | |
Measuring mode | Capacitive ceramic diaphragm vacuum controller | |
Vacuum gauge tube | Capacitive ceramic diaphragm vacuum gauge | |
Cooling mode | Air cooling | |
Pumping speed | 1L/S | |
HQZ-iv | Control mode | CS200 mass flowmeter with a communication interface to connect the computer control |
Flow | 0-500SCCM /0-1SLM, (customized) | |
linear | ±0.5%F.S. | |
Accuracy | ±1%F.S. | |
Repeat accuracy | ±1%F.S. | |
Respond time | ≤1sec | |
Zero drift | <0.6%F.S. | |
Max temp | 3MPa | |
Gas channel | 4 routes (customized) | |
Interface | SwagelokΦ6mm |